MENU

Click here to

×

Are you sure ?

Yes, do it No, cancel

DISCLAIMER:
Entry of taxonomy/keywords during proffered abstract submission was optional.
Not all abstracts will appear in search results.

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # | show all

Keywords: Treatment Techniques
MO-C930-GePD-F3-2Reduction of Integral Dose with Posterior Limited-Angle VMAT Planning in the Treatment of CSI
S Lachowicz*, J Molloy , J Feddock , W St.Clair , D Pokhrel , University of Kentucky, Lexington, KY
MO-J430-CAMPUS-F3-3Energy-Dependent OAR Sparing and Dose Conformity for Total Marrow Irradiation of Obese Patients
A Cherpak1,2,3*, T Monajemi1,2,3 , K Chytyk-Praznik1,2,3 , L Mulroy1,2 , (1) Nova Scotia Cancer Centre, Nova Scotia Health Authority, Halifax, NS, (2) Department of Radiation Oncology, Dalhousie University, Halifax, NS, (3) Department of Physics and Atmospheric Sciences, Dalhousie University, Halifax, NS
SU-F-209-7Gantry Static Couch Motion Optimization Technique (GsCMOT) for Breast Boost Applications: Reduces Dose to Organs-At-Risk and Improves Dosimetric Indices
G Gill*, R Jakubovic , J Chang , Long Island Jewish Medical Center, Northwell Health, NY
SU-I-GPD-P-17Development of Self-Guided Introductory Treatment Planning Modules for the Eclipse TPS
B Loughery1*, E Pryser2 , D Golden3 , K Masi1 , M Dominello1 , H Beydoun1 , J Burmeister1 , (1) Wayne State university School of Medicine, Detroit, MI, (2) UNC Hospitals, Chapel Hill, NC, (3) University of Chicago Medicine, New Lenox, IL
SU-I-GPD-P-41Surface Dose Considerations in Prone Breast Treatment
S McNeeley*, Princeton Radiation Oncology Ctr., Langhorne, PA
SU-I-GPD-T-347Assessing Dosimetric Improvements in Left-Sided Breast Cancer Patients with IMN Involvement Using VMAT and Deep Inspiration Breath Hold
SK Edgington*, LT Vanbenthuysen, J Pursley, AG Taghian, SM MacDonald, RB Jimenez, DP Gierga, Massachusetts General Hospital and Harvard Medical School, Boston, MA
SU-I-GPD-T-356Prostate Treatment in a MR-Linac for Patients with Bilateral Hip Implants
S Ahmad*, M Paudel , A Sahgal , B Keller , M Wronski , Sunnybrook Odette Cancer Centre, Toronto, Canada and University of Toronto, Department of Radiation Oncology, Toronto, Canada
SU-I-GPD-T-425Assessment of Feasibility of Spine Stereotactic Body Radiotherapy for Re-Irradiation Patients with Metastases to More Than Two Vertebrae
T Furuya*, K Ito , K Nihei , K Karasawa , Tokyo Metropolitan Cancer and Infectious Diseases Center Komagome Hospital, Tokyo, Japan
SU-K-209-3Characterization and Validation of 3D Printed High Dose Rate Brachytherapy Applicators
A Wiles1*, S Pokhrel1 , T Knewtson1 , Y Jia1 , D Goldbaum1 , M Ballo1,2 , E W Izaguirre1,2 , (1) university Tennessee Health Science Center, Methodist university Hospital, Memphis, TN, (2) West Cancer Center, Germantown, TN
SU-K-KDBRA2-7Feasibility of a Step-And-Arc Total Marrow Irradiation (TMI) Treatment Planning
T Wu*, E Pearson , B Aydogan , The University of Chicago, Chicago, IL
SU-L-DBRA-4Evaluation of Hyperarc SRS Planning for Linacs with Standard- and Micro-MLC: Comparison with Gamma Knife
E Bossart*, M Monterroso , N Elsayyad , E Mellon , N Dogan , University of Miami Miller School of Medicine, Department of Radiation Oncology, Miami, FL
TH-AB-DBRA-9Method to Quantify the PTV Margin Required for Patients Treated with MLC Tracking for Lung SABR
V Caillet1,2*, B Swan4,5 , A Briggs2 , N Hardcastle3,7 , D Jayamanne2 , T Eade 2, P Greer5,6 , R O'Brien1 , P Keall1 , J Booth2,(1) ACRF Institute X, University Of Sydney, NSW,(2) Royal North Shore Hospital, St Leonards, NSW, (3) Peter MacCallum Cancer Centre, Melbourne, Victoria, (4) Calvary Mater Newcastle, Newcastle, (5) Central Coast Cancer Centre, Gosford, Australia,(6) Faculty of Science and IT, School of Mathematical and Physical Sciences, The University of Newcastle, Newcastle, Australia, (7) Institute of Medical Physics, University of Sydney, Sydney, NSW
TH-AB-DBRA-12Potential of Jaw Tracking Technique in Flattening Filter-Free Beam for Lung Stereotactic Body Radiation Therapy
Y Murakami*1 2, F Matsubayashi1 , T Magome2 , R Takahashi1 , M Arima1 , T Kamima1 , M Nakano1 , T Sato1 , Y Yoshioka1 , M Oguchi1 , (1) The Cancer Institute Hospital of Japanese Foundation for Cancer Research, Koto-ku, Tokyo, (2) Komazawa University, Setagaya-ku, Tokyo
TH-AB-KDBRA1-14piVMAT for Efficient Delivery of Highly Conformal Non-Coplanar Plans
Q Lyu*, V Yu , D O'Connor , R Neph , D Ruan , K Sheng , UCLA School of Medicine, Los Angeles, CA
TH-AB-KDBRA1-10Simulation and Validation of a Gantry Static Couch Motion Optimization Technique (GsCMOT): A Feasibility Study
R Jakubovic*, G Gill , J Chang , Northwell Health, Lake Success, NY
TH-CD-DBRA-11The Implementation of Real-Time Image-Guided Adaptive Radiotherapy for a Fixed-Beam Radiotherapy Prototype
P Liu1*, D Nguyen1 , R O'Brien1 , P Keall1 , J Booth1,2 , (1) The University of Sydney, Camperdown, NSW, (2) Royal North Shore Hospital, St Leonards,
TU-C1030-GePD-F9-3Velocity-Based Selection of Gating Phases Using 4DCT Respiratory Waveform Analysis
N Manohar*, T Wang , X Yang , S Dresser , P Patel , K Higgins , T Liu , A Dhabaan , Emory University, Atlanta, GA
TU-D-KDBRA1-5Performance of a Dual-Layer Staggered MLC System in Stereotactic Treatment for Multiple Brain Metastases with a Single Isocenter: A Dosimetric Comparison Across Three Delivery Techniques
T Li1*, H Liu2 , W Shi2 , J Zou1 , B Teo1 , L Dong1 , (1) University of Pennsylvania, Philadelphia, PA, (2) Thomas Jefferson University, Philadelphia, PA
TU-E115-GePD-F4-6Trajectory-Based Dynamic Couch Motion Optimization Technique for Intracranial Stereotactic Radiosurgery: A Single π-Based Geometry Approach for Brain SRS Treatment Planning
G Gill*, R Jakubovic , J Chang , Long Island Jewish Medical Center, Northwell Health, NY
TU-E115-GePD-F9-3Electronic Tissue Compensation (eComp) Technique Decreases Acute Skin Toxicity For Whole Breast Irradiation Patients With Early-Stage Breast Cancer After Breast Conserving Surgery
Y Song1* , L Tong2 , L Gan3 , T Zhang4 , J Dang5 , X Chen6 , (1) Chongqing Medical University, Chongqing, China, (2) Chongqing Medical University, Chongqing, China, (3) Chongqing Medical University, Chongqing, China, (4) Chongqing Medical University, Chongqing, China, (5) Chongqing Medical University, Chongqing, China, (6) Chongqing Medical University, Chongqing, China
TU-I345-GePD-F4-2Developing An Automatic Planning System for Total Body Irradiation (TBI)Treatment Using Volumetric Modulated Arc Therapy (VMAT)
J Tan*, T Chiu , Y Yan , M Lin , P Lee , S Jiang , X Gu , UT Southwestern Medical Center, Dallas, TX
TU-I345-GePD-F4-4Flattening Filter Free VMAT Delivery of Total Body Irradiation at An Extended SSD: A Treatment Planning Feasibility Study
R Frederick*1,2, A Hudson1,2, G Pierce1,2, (1) University of Calgary, Calgary, AB, (2) Tom Baker Cancer Centre, Calgary, AB
TU-K-KDBRC-6NYU Approach to CT-Based Planning Total Body Irradiation (TBI)
P Galavis*, N Mistry , J Teruel , N Gerber , K Osterman , S Ayyalasomayajula , C Hitchen , NYU Langone Health, New York, NY
WE-C1030-GePD-F9-6Use of Passive Intensity Modulation for Bolus Electron Conformal Therapy
R Carver1,2*, E Chambers2 ,E Hilliard2 , K Erhart3, K Hogstrom1,2 , (1) Mary Bird Perkins Cancer Center, Baton Rouge, LA, (2) LSU Dept. of Physics & Astronomy, Baton Rouge, LA, (3) .decimal, LLC Sandford, FL 32771
WE-C930-GePD-F4-3Evaluating the Dosimetric Accuracy of Small Gating Windows in Radiotherapy
W Short*, N Sperling , University of Toledo Medical Center, Toledo, OH
WE-C930-GePD-F7-13D Printed Patient-Specific Mould for HDR GYN Treatment
S Wadi-Ramahi1*, N Jastaniyah1 , C Constantinescu1 , A Nobeh1 , F DeBlois2 , (1) King Faisal Specialist Hospital and Research Center, Riyadh, Saudi Arabia, (2) Montreal General Hospital, Montreal, QC
WE-C930-GePD-F7-5Validation of Patient-Specific 3D-Printed Bolus Caps for Clinical Use in Total Scalp Irradiation
G C Baltz*, P Chi, P Wong, C Wang, D Craft, S Kry, S Lin, A S Garden, R M Howell, MD Anderson Cancer Ctr., Houston, TX
WE-C930-GePD-F9-6The Use of Multiple Isocenters to Achieve Non-Coplanar Treatment Geometry
L Hall*, E Johnson , university Kentucky Medical Ctr, Lexington, KY
WE-J-KDBRC-9A Solution to Gantry Angle Dependent Magnetic Field Inhomogeneities for MR-IGRT
HM Gach1*, S Nikolova2 , R Nikolov2 , R Lotey2 , S Mutic1 , O Green1 , (1) Washington University in St. Louis, St. Louis, MO, (2) ViewRay, Mountain View, CA