DISCLAIMER:
Entry of taxonomy/keywords during proffered abstract submission was optional.
Not all abstracts will appear in search results.
SU-F-202-7 | Cherenkov Imaging for TSE - 3D Imaging H Petroccia1*, Y Xie1 , T Miao1,2 , Y Zhu1 , P Bruza2 , B Pogue2 , T Zhu1 , (1) University of Pennsylvania, Philadelphia, PA, (2) Dartmouth College, Hanover, NH, |
SU-F-DBRA-7 | Novel Tungsten Filled 3D Printed Electron Beam Shaping Devices: Design and Evaluation L Skinner*, B Fahimian , A Yu , Stanford University, Stanford, CA |
SU-H330-GePD-F4-6 | Technique for Commissioning Lying-On-The-Floor Total Skin Electron Therapy for Emergency Palliation E Dziemianowicz*, E Laugeman , N Wen , Henry Ford Health System, Detroit, MI |
SU-I-GPD-P-24 | Monitoring Electron Beam Energy Constancy Using a 2D Ionization Chamber Array with Double-Wedge Phantom S Gao*, M Chetvertkov , P Balter , M.D. Anderson Caner Center, Houston, TX |
SU-I-GPD-P-27 | Correlation of Scalp Dose Coverage as a Function of Patient Height for Total Skin Electron Irradiation Using the Modified Stanford Technique U Robins1*, T Poozhikala2 , M Chuong3 , M Hall4 , H Robins5 , V Mishra6 , A Gutierrez7 , (1) Miami Cancer Institute , Miami, FL, (2) Miami Cancer Institute, Miami, FL, (3) Miami Cancer Institute, Miami, FL, (4) Miami Cancer Institute, Miami, FL, (5) Riviera Middle School, Miami, Florida, (6) Baptist Hospital, Miami, FL, (7) Miami Cancer Institute , Miami, FL |
SU-I-GPD-T-49 | Monte Carlo Simulation of In Vivo Verification for Small Aperture Electron Radiotherapy K Li*, Associates In Medical Physics, Lanham, MD |
SU-I-GPD-T-55 | Electron Monte Carlo Comparison to Hand Calculations and Phantom Measurements K Chu*, V Potari , R Rostock , M DeLuca , Western Connecticut Health Network, Danbury Hospital, Danbury, CT |
SU-I-GPD-T-56 | Modeling of Applicator Free Electron Beams S Crooks*, E Klein , Rhode Island Hospital / Warren Alpert Medical School at Brown University, Providence, RI |
SU-I-GPD-T-57 | Building An Electron Cutout Factor Table M Vossler*, Cleveland Clinic, Cleveland, OH |
SU-I-GPD-T-61 | A Novel Technique for Scleredema Treatment Using Electron Therapy N Neba1*, S Howard2 , J Coster3 , A Brito Delgado4 , H Saleh5 , K Guida6 , (1) ,,,(2) University of Kansas Health System, Overland Park, KS, (3) University of Kansas Health System, Overland Park, KS, (4) University of Kansas Hospital, Shawnee, KS, (5) University of Kansas Medical Center, Kansas City, Kansas, (6) University of Kansas Hospital, Kansas City, MO |
SU-I-GPD-T-62 | Use of Acrylic Electron Templates for Degradation of 9MeV Electron Beams for Boost in Total Skin Electron Treatments U Robins*, M Chuong , M Hall , V Mishra , A Gutierrez , T Poozhikala , Miami Cancer Institute, Miami, FL |
SU-I-GPD-T-453 | Investigation of Small Field Electron Beams for Preclinical Irradiation D Parsons*, X Gu , S Stojadinovic , M Chen , S Jiang , W Lu , UT Southwestern Medical Center, Dallas, TX |
SU-L-DBRA-2 | Developing a Low Cost Plasma Accelerator for Flash Radiotherapy Studies r Alibazi behbahani*, Q Diot , B Kavanagh , N J.Serkova , M Miften , D Westerly , University of Colorado School of Medicine, Aurora, CO |
TU-C930-GePD-F3-1 | A Simple Approach to Perform Fast Electron Beam QA and Pre-Treatment Verification in Absolute Dose Using EPID A Sors1*, P Dudouet1,2 , D Franck2 , M Mace1 , P Boucarut1 , C Boutry1 , (1) Clinique du Pont de Chaume - Groupe Oncorad Garonne, Montauban, France (2) Clinique Pasteur - Groupe Oncorad Garonne, Toulouse, France |
TU-J430-CAMPUS-F3-2 | Custom 3-D Printed Skin Compensating Bolus and Collimation Shielding A Rapchak*, T Bista , C Page , T Sokolowski , A Sadeghi , Banner MD Anderson Cancer Center, Gilbert, AZ |
TU-K-DBRA-2 | Design and Validation of 3D Printed Patient Specific Tissue Compensators for Post Mastectomy Radiation Therapy D Craft1*, S Kry1 , P Balter1 , W Woodward2 , M Salehpour1 , G Baltz1 , M Peters1 , R Howell1 , (1) Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, (2) Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX |
TU-K-KDBRC-5 | Modulated Electron Arc Therapy (MEAT) with 3D Bolus and Photon MLC for Chest Wall Radiotherapy C Ma*, D Parsons , M Chen , X Gu , W Lu , UT Southwestern Medical Center, Dallas, TX |
WE-C1030-GePD-F3-1 | Clinical Impact of Upgrading Electron Calculation From Pencil Beam to Monte Carlo for Accelerated Partial Breast Irradiation (APBI) S Zieminski*, Y Wang , Department of Radiation Oncology, Massachusetts General Hospital, Harvard Medical School, Boston, MA |
WE-C1030-GePD-F9-6 | Use of Passive Intensity Modulation for Bolus Electron Conformal Therapy R Carver1,2*, E Chambers2 ,E Hilliard2 , K Erhart3, K Hogstrom1,2 , (1) Mary Bird Perkins Cancer Center, Baton Rouge, LA, (2) LSU Dept. of Physics & Astronomy, Baton Rouge, LA, (3) .decimal, LLC Sandford, FL 32771 |
WE-FG-KDBRA1-6 | Development of Quality Assurance Method for Dynamic Electron Arc Radiotherapy (DEAR) X Wang1*, D Sawkey2 , Q Wu1 , (1) Duke University Medical Center, Durham, NC, (2) Varian Medical Systems, Palo Alto, CA |