DISCLAIMER:
Entry of taxonomy/keywords during proffered abstract submission was optional.
Not all abstracts will appear in search results.
MO-AB-303-0 | Advances in Ultrasound Guidance and Planning for Brachytherapy J Cunha1*, A Fenster2*, W Bice3*, (1) UC San Francisco, San Francisco, CA, (2) Robarts Research Institute, London, Ontario, (3) John Muir Medical Center, Lafayette, CA |
MO-AB-303-1 | Ultrasound: a modality of choice for real-time guidance and planning in brachytherapy J Cunha1*, A Fenster2*, W Bice3*, (1) UC San Francisco, San Francisco, CA, (2) Robarts Research Institute, London, Ontario, (3) John Muir Medical Center, Lafayette, CA |
MO-AB-303-2 | 3-dimensional ultrasound for prostate, GYN and breast brachytherapy J Cunha1*, A Fenster2*, W Bice3*, (1) UC San Francisco, San Francisco, CA, (2) Robarts Research Institute, London, Ontario, (3) John Muir Medical Center, Lafayette, CA |
MO-AB-303-3 | Practical US guidance of GYN implants with real-time Doppler J Cunha1*, A Fenster2*, W Bice3*, (1) UC San Francisco, San Francisco, CA, (2) Robarts Research Institute, London, Ontario, (3) John Muir Medical Center, Lafayette, CA |
MO-AB-303-5 | Development and Validation of a Power Doppler Ultrasound Method for Improved Intraoperative Needle Tip Visualization During High-Dose-Rate Brachytherapy N Orlando1,2*, J Snir3 , K Barker2 , D Hoover4 , A Fenster1,2 , (1) Department of Medical Biophysics, Western University, London, Ontario, Canada, (2) Robarts Research Institute, Western University, London, Ontario, Canada, (3) Tom Baker Cancer Centre, Calgary, Alberta, Canada, (4) London Regional Cancer Program, London, Ontario, Canada |
MO-C930-GePD-F4-1 | Investigation of the Role of Contour Propagation for Volumetric Planning in Patients Receiving High Dose Rate (HDR) Brachytherapy for the Treatment of Cervical Cancer S Simiele1*, R Kashani1 , D Owen1 , K Vineberg1 , S Jolly1 , C Chapman1,2, L Young1 , A Dougherty1 , J Prisciandaro1 , (1) University of Michigan, Ann Arbor, MI, (2) VA Ann Arbor Healthcare System, Ann Arbor, MI |
MO-C930-GePD-F4-3 | Novel Semi-Automatic Reconstruction Method for Plastic Gynaecological Applicators A Otal1,4*, J Vijande2,4 , F Ballester2,4 , A Forner1 , O Ripol1 , C Monfa1 , S Serrano1 , J Perez-Calatayud3,4 (1) Hospital Universitari Arnau de Vilanova, Lleida (2) University of Valencia, Burjassot (3) Hospital La Fe, Valencia (4) Medical Physics Research Group La Fe-UVEG |
MO-C930-GePD-F4-4 | Post-Operative Radiation Exposure and Patient Release Following Cs-131 Mesh Implant for Recurrent Head and Neck Cancer Z Xu1*, J Muenkel1 , G Warrell2 , M Yao1,3 , C Zender1,3 , T Podder1,3 , (1) University Hospital Case Medical Center, Cleveland, OH, (2) Franciscan Health, Highland, IN, (3) Case Western Reserve Univeristy, School of Medicine ,Cleveland, OH |
MO-C930-GePD-F4-5 | Spatial, Dosimetric, and Radiobiological Robustness of Template-Based Interstitial High-Dose-Rate Gynecologic Brachytherapy M Ostyn1*, A Burke2, E Fields1, D Todor1, (1) Virginia Commonwealth University, Richmond, VA, (2) Georgetown University, Washington, DC |
MO-C930-GePD-F4-6 | Feasibility Study of Focal Salvage High Dose Rate (HDR) Brachytherapy After Neurovascular-Sparing Prostate Stereotactic Ablative Radiation Therapy (SAbR) N Hassan Rezaeian*, B Gannavarapu , R Hannan , M Folkert , A Garant , R Timmerman , B Hrycushko , N Desai , The University of Texas Southwestern Medical Ctr, Indianapolis, IN |
MO-E115-GePD-F6-5 | A Knowledge-Based Organ Dose Prediction Tool for Brachytherapy Treatment of Cervical Cancer Patients T I Yusufaly*, A Simon, S Hild, D Brown, D Scanderbeg, J Mayadev, K L Moore, S M Meyers, University of California, San Diego, La Jolla, CA |
MO-E115-GePD-F6-6 | Development of Volume-Based Second-Check Dose Calculation Software for Image-Guide Adaptive Brachytherapy S Kang1*, J Chung2 , K Kim1 , J Park3 , T Suh1 , J Park4 , (1) Department of Biomedicine & Health Sciences, Research Institute of Biomedical Engineering, College of Medicine, the Catholic University of Korea,(2) Department of Radiation Oncology, Seoul National University Boramae Medical Center,(3) Deapartment of Radiation Oncology, University of Florida, Gainesville, FL,(4) Department of Radiation Oncology, Washington University in St. Louis, St. Louis, MO |
MO-GH-SAN2-3 | Enabling 3D Ultrasound Needle Guidance During Implant Placement Procedures for High-Dose-Rate Interstitial Gynecologic Brachytherapy J Rodgers1*, J Bax1 , K Surry2 , W Hrinivich3 , E Raščevska4 , E Leung5 , V Velker2 , D D'Souza2 , A Fenster1 , (1) Robarts Research Institute, Western University, London, Ontario, (2) London Regional Cancer Program, London, Ontario, (3) Johns Hopkins University School of Medicine, Baltimore, Maryland, (4) University of Twente, Enschede, The Netherlands, (5) Odette Cancer Centre, Toronto, Ontario |
PO-GePV-E-9 | Use of Hands-On Laboratory Sessions to Teach Brachytherapy Treatment Planning Concepts J Huang*, B Thomadsen , J Miller , University of Wisconsin, Madison, WI |
PO-GePV-I-6 | Optimized Rotating Shield Brachytherapy Treatment Plan Under Treatment Time Budget J Yi1*, X Wu2 , Q Adams3 , K Hopfensperger4 , K Patwardhan5 , R Flynn6 , Y Kim7 , W Xu8 , (1) Department of Electrical and Computer Engineering, University of Iowa, Iowa City, IA, (2) Department of Electrical and Computer Engineering, University of Iowa, Iowa City, IA, (3) Department of Radiation Oncology, University of Iowa Hospitals and Clinics, Iowa City, IA, (4) Department of Radiation Oncology, The University of Iowa, Iowa City, IA, (5) Department of Radiation Oncology, University of Iowa, Iowa City, IA, (6) University of Iowa Hospitals and Clinics, Iowa City, IA, (7) College of Medicine, University Of Iowa, Iowa City, IA, (8) Department of Electrical Engineering, The University of Iowa, Iowa City, IA |
PO-GePV-P-70 | Study On the Brachytherapy Applicator of Vaginal Cylinder Based On 3D Printing Technology L Yu1*, B Yang1 , X Liu1 , T Pang1 , N Liu1 , J Qiu1 , (1) Department Of Radiation Oncology,Peking Union Hospital,Chines Academy of Medical Sciences,Peking Union Medical College,Beijing 100730,China |
PO-GePV-T-1 | Investigation of the Directional Dependence of the Detector Response Near a 192Ir Brachytherapy Source K Buesing*, A Schoenfeld , B Poppe , Medical Campus Pius Hospital, Carl von Ossietzky University, Oldenburg, Germany |
PO-GePV-T-3 | A Semi-2D TG-43 Formula for Accurate In-House Verification of High-Dose-Rate Brachytherapy Dose Calculation Q Fan*, D Zheng , S Wang , C Lin , C Enke , S Zhou , University of Nebraska Medical Center, Omaha, NE |
PO-GePV-T-5 | Evaluation of a Deep Neural Network Model for Automatic Seeds Identification in Prostate Implant Dosimetry Y Yuan*, R Sheu , L Fu , Y Lo , The Mount Sinai Medical Center, New York, NY |
PO-GePV-T-6 | Evaluation of a Time-Based Plan Check Method for Rotte 'Y' and Venezia Brachytherapy Treatments J Hansen*, R Das , University of Wisconsin, Madison, WI |
PO-GePV-T-7 | Impact of Beam Quality On Three-Dimensional Dose Distribution Evaluation Using a Normoxic N-Vinylpyrrolidone-Based Polymer Gel for HDR Brachytherapy M Itano1*, Y Watanabe2 , S Mizukami2 , T Maeyama2 , T Terazaki3 , R Uehara4 , H Tachibana4 , (1) Funabashi municipal medical center, Funabashi, 12, (2) Kitasato University, Sagamihara, ,(3) Yokohama City Minato Red Cross Hospital, Yokohama, ,(4) National Cancer Center Hospital East, Kashiwa, |
PO-GePV-T-12 | Demonstration of the Need for An Air-Kerma Rate Standard for the Newest Model of the Xoft Axxent TM Source A Walter*, D Anderson , L DeWerd, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, WI |
PO-GePV-T-13 | Evaluation of the Dose Distributions for HDR Brachytherapy Using Skin Applicator as a Function of Geometry O Elhanafy1*, A Mahmoudieh2 , B Paliwal3 , B Thomadsen4 , (1) El Portal Radiation Oncology Center, Merced, CA, (2) Elportal Cancer Center, Merced, CA, (3) University of Wisconsin, Madison, WI, (4) University of Wisconsin, Madison, WI |
PO-GePV-T-14 | Planning Margins and Inter-Fraction Motion for Inpatient Interstitial HDR Brachytherapy W Campbell*, C Fisher , M Miften , L Schubert , University of Colorado School of Medicine, Aurora, CO |
PO-GePV-T-15 | A Feasibility Study of Using Ir-192 High Dose Rate (HDR) Source for Spatially Fractionated Grid Radiation Therapy H Zhang1*, (1) Northwestern Memorial Hospital, Chicago, IL |
PO-GePV-T-16 | Observation Of Short-Term Efficacy In Image-Guided Adaptive Intraluminal High-Dose-Rate Brachytherapy For The Treatment Of Malignant Obstructive Jaundice L Sun*, W Hu , J Zhao , R Jiang , H Huang , |
PO-GePV-T-17 | Dosimetric Evaluation of Multi-Channel Cylinders for High Dose Rate Vaginal Cuff Brachytherapy Using a Cylindrical Target Volume S Kucuker Dogan*, Z Kang , J Cates , H Zhang , Northwestern Memorial Hospital, Chicago, IL |
PO-GePV-T-23 | Treatment of a Vasoproliferative Retinal Tumor (VPT) Using I-125 Eye Plaque Radiotherapy S Howard1*, V Massey2 , S Howard3 , (1) University of Kansas Hospital, Overland Park, KS, (2) University of Kansas Medical Center, Overland Park, KS |
PO-GePV-T-24 | An Investigation of Image Registration Techniques for Dose Summation of External Beam Radiation Therapy and Prostate Seed Implants S To1,2*, D Guest2 , A Riegel1,2 , (1) Department of Physics and Astronomy, Hofstra University, Hempstead, NY 11549, (2) Department of Radiation Medicine, Northwell Health, Lake Success, NY 11042 |
PO-GePV-T-25 | Dosimetric Evaluation of the Intrabeam and Axxent System for Breast IORT M Shaikh1*, S Tanny2 , (1) Rochester General Hospital, Rochester, NY, (2) SUNY Upstate Medical University, Manlius, NY |
PO-GePV-T-26 | Comparison of Automatic and Manual Catheter Reconstruction Methods for the Lunar Ovoid Channels of the Venezia Applicator J Hansen*, D Dunkerley , J Miller , J Huang , University of Wisconsin, Madison, WI |
PO-GePV-T-30 | Inter-Observer Variabilities in Applicator Reconstruction and the Dosimetric Impact in HDR Gynecological Brachytherapy R Zakariaee1,2*, J Borg3 , A Beiki-Ardakani3 , R Weersink1,3,4 , (1) Department of Radiation Oncology, University of Toronto, Toronto, ON, (2) Radiation Medicine Program, Stronach Regional Cancer Center, Newmarket, ON, (3) Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, ON, (4) Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, ON |
PO-GePV-T-31 | RapidBrachyMCTPS: Addition of Contouring Tools to the Monte Carlo-Based Treatment Planning System for Brachytherapy Applications Harry Glickman*1, Majd Antaki1, Shirin A. Enger1,2,3, (1) Medical Physics Unit, McGill University, Montreal, Quebec, H4A 3J1, Canada (2) Department of Oncology, McGill University, Montreal, Quebec, H4A 3J1, Canada (3) Research Institute of the McGill University Health Centre, Montreal, Quebec, H3H 2L9, Canada |
PO-GePV-T-32 | A Dosimetric Comparative Study of the Dose Coverage of the Tumor in Treatment of Cervical Cancer by Prescribing to Point A (Manchester Method) Versus Prescribing to the Volume Based Treatment According to ICRU 89 Recommendation U Robins1*, S George2 , A Garcia-Serra3 , T Romaguera4 , V Mishra5 , A Gutierrez6 , (1) Miami Cancer Institute, Miami, FL, (2) Miami Cancer Institute, Miami, AA, (3) Miami Cancer Institute, Miami, ,(4) Miami Cancer Institute, Miami, FL, (5) Baptist Hospital, Miami, FL, (6) Miami Cancer Institute, Miami, FL |
PO-GePV-T-91 | Pilot Study On Critical Structure Dosing for Ocular Melanoma Radiation Techniques: An Analysis of I-125 Brachytherapy Plaque and Dedicated Proton Eye Beamline Treatment Planning Dosimetry J Scholey1*, V Weinberg1 , I Daftari1 , K Mishra1 , (1) University of California San Francisco, San Francisco, CA |
SU-E-301-1 | Clinical Experience in Brachytherapy with the Venezia(TM) Advanced Gynecological Applicator E Schnell*, S Thompson , S Ahmad , T Herman , T De La Fuente Herman , University of Oklahoma Health Sciences Center, Oklahoma City, OK |
SU-E-301-2 | Dosimetric Impact of a Curvature On a Directional LDR Brachytherapy Source Array M Aima1*, L DeWerd2 , C Hammer2 , W Culberson2 , (1) University of Texas M.D. Anderson Cancer Center, Houston, TX, (2) University of Wisconsin-Madison, Madison, WI |
SU-E-301-6 | Time-Resolved Gamma Imaging of High Dose Rate (HDR) Brachytherapy Source Positions K Jones*, Y Liao , Z Grelewicz , D Bernard , J Turian , Rush University Medical Center, Chicago, IL |
SU-F-301-2 | Development and Clinical Implementation of An Automated Ionizing Radiation Free Treatment Planning Approach for Complex Skin Brachytherapy C V Guthier*, T C Harris , D A O'Farrell , M S Bhagwat , S Aldelaijan , P M Devlin , R A Cormack , I Buzurovic , Department of Radiation Oncology, Brigham and Women's Hospital and Dana-Farber Cancer Institute, Harvard Medical School, Boston, MA |
SU-F-301-3 | Enabling Rotating Shield Brachytherapy with Efficient Yb-169 High-Dose-Rate Brachytherapy Source Production by Re-Activation R Flynn1*, Q Adams1, K Hopfensperger2, X Wu1,3, W Xu3, Y Kim1, (1) Department of Radiation Oncology, The University of Iowa, Iowa City, IA, (2) Department of Biomedical Engineering, The University of Iowa, (3) Department of Electrical and Computer Engineering, The University of Iowa |
SU-F-301-5 | Monte Carlo Simulation of I-125 Brachytherapy Seed Model IAI-125A H Yan1,2*, W Liu1, (1) Yale Univ. School of Medicine, New Haven, CT, (2) Capital Medical University, Beijing, China |
SU-F-301-7 | Use of a Tandem and Ring Applicator Reference-CT to Improve Digitization in MR-Based Brachytherapy Planning I Malajovich1*, B Teo2 , O Dolney3 , W Arscott4 , N Taunk5 , S Anamalayil6 , (1) University of Pennsylvania, Philadelphia, PA, (2) UNIVERSITY OF PENNSYLVANIA, Philadelphia, PA, (3) University Of Pennsylvia Hospital, Philadelphia, PA, (4) Univ. of Pennsylvania, Philadelphia, ,(5) University of Pennsylvania, Philadelphia, PA, (6) University of Pennsylvania, Philadelphia, PA |
SU-I430-GePD-F4-2 | Characterization of a Gynaecological Titanium Applicator for Direct Reconstruction On MRI A Otal1,4*, J Vijande2,4 , F Ballester2,4 , A Forner1 , O Ripol1 , C Monfa1 , S Serrano1 , J Perez-Calatayud3,4 (1) Hospital Universitari Arnau de Vilanova, Lleida (2) University of Valencia, Burjassot (3) Hospital La Fe, Valencia (4) Medical Physics Research Group La Fe-UVEG |
SU-I430-GePD-F4-5 | Skin Dose Measurements with Optically Stimulated Luminescence Dosimeters for SAVI Breast Brachytherapy Treatment Quality Assurance L Young1*, J Van Schelt2 , D Wang3 , A Kalet4 , N Cao5 , J Meyer6 , R Price7 , C Dempsey8 , J KIm9 , L Young10 , (1) Univ Washington, Seattle, WA, (2) Rush University Medical Center, Chicago, IL, (3) University of Washington Medical Center, Seattle, WA, (4) University of Washington, Seattle, WA, (5) University of Washington, Seattle, WA, (6) University of Washington Medical Center, Seattle, WA, (7) University of Washington, Seattle, WA, (8) The University of Newcastle, Newcastle, ,(9) Seattle Cancer Care Alliance, Seattle, ,(10) Univ Washington, Seattle, WA |
SU-I430-GePD-F4-6 | Dosimetric Effects of Varying Dwell Position Step Size in Mesh HDR Brachytherapy for Skin Lesions J Cates*, Z Kang, S Kucuker Dogan, H Zhang, Northwestern Memorial Hospital, Chicago, IL |
SU-L-301-8 | Simulation-Based Ability of a Real-Time Fiber-Optic Detector to Catch Gross Errors in T&O HDR Brachytherapy Treatments X Shen1*, O Craciunescu3 , M Rokni3 , P Maccarini1 , B Langloss1 , M Therien1 , T Yoshizumi3 , J Chino3 , (1) Duke University, Durham, NC, (2) University of Chicago, Chicago, IL, (3) Duke University Medical Center, Durham, NC, |
SU-L-302-6 | Radiation Dose to Adjacent Tissue and Distant Organs in the Course of Clinical Trials with Diffusing Alpha-Emitters Radiation Therapy L Arazi1*, M Schmidt2 , T Cooks3 , A Roy4 , M Efrati5 , N Barel6 , A Sosnovitch7 , I Barsky8 , R Ben-Hur9 , A Mizrachi10 , E Rosenfeld11 , A Popovtzer12 , Y Keisari13 , I Kelson14 , (1) Ben-Gurion University of the Negev, Beer-Sheva, Israel, (2) Alpha TAU Medical, Tel Aviv, Israel ,(3) Ben-Gurion University of the Negev, Beer-Sheva, Israel ,(4) Ben-Gurion University of the Negev, Beer-Sheva, Israel ,(5) Tel Aviv University, Tel Aviv, Israel ,(6) Alpha TAU Medical, Tel Aviv, Israel ,(7) Alpha TAU Medical, Tel Aviv, Israel ,(8) Alpha TAU Medical, Tel Aviv, Israel ,(9) Rabin Medical Center, Petah Tikva, Israel ,(10) Rabin Medical Center, Petah Tikva, Israel ,(11) Rabin Medical Center, Petah Tikva, Israel ,(12) Rabin Medical Center, Petah Tikva, Israel ,(13) Tel Aviv University, Tel Aviv, Israel ,(14) Tel Aviv University, Tel Aviv, Israel |
TH-A-225BCD-10 | Modeling Complex Deformations of the Sigmoid Between External Beam Radiotherapy and Brachytherapy Images of Cervical Cancer B Rigaud*, A Klopp , S Vedam , A Venkatesan , N Taku , G Cazoulat , K Brock , UT MD Anderson Cancer Center, Houston, TX |
TH-A-225BCD-11 | Multimodal Image Fusion for Prostate Biopsy and Focal Brachytherapy with Convolutional Neural Network Autosegmentation and Anatomical Landmark-Based Registration S Sultana , A Robinson , D Song , J Lee*, Johns Hopkins University, Baltimore, MD |
TH-A-301-1 | BEST IN PHYSICS (THERAPY): Deep-Learning Assisted Automatic Digitization of Interstitial Needles in High Dose-Rate Brachytherapy H Jung*, C Shen , Y Gonzalez , X Jia , University of Texas Southwestern Medical Center, Dallas, TX |
TH-A-301-4 | Delivering Intracavitary/Interstitial Brachytherapy Equivalent Dose Distributions with An Intracavitary-Only Helical Rotating Shield Brachytherapy Approach for Cervical Cancer Treatment K Hopfensperger1*, Q Adams2, Y Kim2, X Wu3, W Xu3, K Patwardhan2, B Thammavong2, R Flynn2, (1) Department of Biomedical Engineering, University of Iowa, Iowa City, IA; (2) Department of Radiation Oncology, University of Iowa Hospitals and Clinics, Iowa City, IA; (3) Department of Electrical and Computer Engineering, University Of Iowa, College of Medicine, Iowa City, IA, |
TH-A-301-5 | High Dose Rate Interstitial Spine Brachytherapy Using An Intraoperative Mobile CT Guided Surgical Navigation System S Park1*, L Macyszyn2 , P Venkat1 , A Lee1 , A Chang1 , (1) Department of Radiation Oncology, University of California Los Angeles, Los Angeles, CA (2) Department of Neurosurgery, University of California Los Angeles, Los Angeles, CA |
TH-A-301-6 | IViST: A Platform for Real-Time In Vivo Source Tracking in HDR Brachytherapy H LINARES ROSALES 1,2*, J JOHANSEN3 , A CANTIN1 , G KERTZSCHER3 , L Archambault1,2 , K Tanderup3 , L Beaulieu1,2 , S Beddar4 , (1) CHU de Quebec-Universite Laval, Quebec, Canada, (2) Physics department and Universite Laval Cancer Research Centre, Quebec, Canada ,(3) Department of Oncology, Aarhus University Hospital, Denmark, (4) The University of Texas MD Anderson Cancer Center, Houston, United States |
TH-A-301-8 | Monte Carlo Simulation and Validation of a Novel Yttrium-90 Source for Use in a Conformal Superficial Brachytherapy Device B Rogers*, P Alaei , J Chmura , E Ehler , J Lawrence , C Wilke , C Ferreira , University of Minnesota, Minneapolis, MN |
TH-A-301-10 | Source Trajectory Generation Algorithm for 3D Printed Surface Brachytherapy Applicators B Basaric1*, (1) Adaptiiv Medical Techologies, Halifax, NS |
TH-A-301-11 | Evaluation of the Intershield Attenuation Effect for a New Intensity Modulated Brachytherapy System for Prostate Cancer G Famulari1*, S A Enger1,2,3, (1) Medical Physics Unit, McGill University,Montreal, QC, (2) Department of Oncology, McGill University, Montreal, QC, (3) Research Institute of the McGill University Health Centre, Montreal, QC |
TH-A-303-10 | Parallel Imaging Compressed Sensing in Fully Balanced SSFP for Prostate Brachytherapy MRI: Pulse Sequence Development and Validation in a Phantom Study J Sanders*, S Frank , J Ma , University of Texas MD Anderson Cancer Center, Houston, TX |
TU-C1030-GePD-F4-3 | Adaptive High-Dose Rate Brachytherapy in the Setting of Recurrent Nasal Carcinoma J Pursley*, A Chan , T Nguyen , T Ruggieri , T Mauceri , Massachusetts General Hospital and Harvard Medical School, Boston, MA |
TU-C1030-GePD-F4-4 | A Geometry-Based Pre-Planning System for Interstitial HDR Brachytherapy Z Tian1,2*, J Tan1 , Y Gonzalez1 , K Albuquerque1 , X Jia1 (1) UT Southwestern Medical Center, Dallas, TX (2) Emory University, Atlanta, GA |
TU-C1030-GePD-F4-5 | Clinical Evaluation of Custom 3D Applicators for High Dose Rate (HDR) Intraoperative Brachytherapy (IORT) G Cohen*, S Wolden , B Imber , A Damato , Memorial Sloan Kettering Cancer Center, New York, NY |
TU-C1030-GePD-F7-3 | Dosimetric Evaluation of Shielding Materials for Critical Organ Protection in 50 KV Intrabeam Intraoperative Radiation Therapy (IORT) S Trichter*, F Kulidzhanov , JK DeWyngaert , New York-Presbyterian Hospital, Weill Cornell Medical Center, New York, NY |
TU-C930-GePD-F2-2 | Evaluation of An MRI-Positive HDR Lumen Markerfor HDR Brachytherapy Treatment Planning N Eclov*, O Craciunescu , J Chino , Z Chang , Duke University Medical Center, Durham, NC |
TU-E-SAN1-6 | The Predictive Value of Tc-99m MAA SPECT/CT for Voxel-Based Tumor Dosimetry of Yttrium-90 Microsphere Therapy P Potrebko*, G Andl , S Bose , T Fox , Varian Medical Systems, Atlanta, GA |
TU-F115-GePD-F1-2 | Initial Experience with MIM SurePlan for Y-90 Treatment Planning M Studenski*, N Patel , B Spieler , R Llorente , H Giap , L Portelance , University of Miami, Miami, FL |
TU-F115-GePD-F1-4 | Evaluating the Necessity of Post-Operative Planning Following Intraoperative Planning and Delivery of Palladium-103 Seeds for Prostate Cancer M Castillo1*, P Taylor2 , AC Riegel3 , (1) Hofstra University, Hopelawn, NJ, (2) Northwell Health, Lake Success, NY, (3) Northwell Health, Lake Success, NY |
TU-F115-GePD-F1-5 | Radiation Safety and Technical Considerations for Implementing 177Lu-Dotatate in a Radiation Oncology-Based Program N Maughan1*, H Kim1 , Y Hao1 , S Unangst2 , M Roach1 , J Garcia-Ramirez1 , M Altman1 , M Amurao1 , J Zoberi1 , (1) Washington University School of Medicine, Saint Louis, MO, (2) University of Missouri, Columbia, MO |
TU-F115-GePD-F4-4 | Report of Radiobiological Doses for the Treatment of Ocular Malignancies with Brachytherapy Z Richards*, B Firestone , C Henson , S Ahmad , T Herman , T De La Fuente Herman , University of Oklahoma Health Sciences Center, Oklahoma City, OK |
WE-AB-301-0 | Cutting-Edge Brachytherapy R Flynn1*, X Yang2*, C Deufel3*, J Zoberi4*, (1) University of Iowa Hospitals and Clinics, Iowa City, IA, (2) Emory University, Atlanta, GA, (3) Mayo Clinic, Rochester, MN, (4) Washington University School of Medicine, St. Louis, MO |
WE-AB-301-1 | Re-inventing High-Dose-Rate Brachytherapy around Ytterbium-169 R Flynn1*, X Yang2*, C Deufel3*, J Zoberi4*, (1) University of Iowa Hospitals and Clinics, Iowa City, IA, (2) Emory University, Atlanta, GA, (3) Mayo Clinic, Rochester, MN, (4) Washington University School of Medicine, St. Louis, MO |
WE-AB-301-2 | Image-Guided Catheter Placement for Prostate HDR Brachytherapy with Focal Tumor Boost using Machine Learning R Flynn1*, X Yang2*, C Deufel3*, J Zoberi4*, (1) University of Iowa Hospitals and Clinics, Iowa City, IA, (2) Emory University, Atlanta, GA, (3) Mayo Clinic, Rochester, MN, (4) Washington University School of Medicine, St. Louis, MO |
WE-AB-301-3 | Real-Time Electromagnetic Tracking in Clinical Brachytherapy Practice R Flynn1*, X Yang2*, C Deufel3*, J Zoberi4*, (1) University of Iowa Hospitals and Clinics, Iowa City, IA, (2) Emory University, Atlanta, GA, (3) Mayo Clinic, Rochester, MN, (4) Washington University School of Medicine, St. Louis, MO |
WE-AB-301-4 | Standardization and Automation of HDR Brachytherapy Plan QA with Application Programming Interface R Flynn1*, X Yang2*, C Deufel3*, J Zoberi4*, (1) University of Iowa Hospitals and Clinics, Iowa City, IA, (2) Emory University, Atlanta, GA, (3) Mayo Clinic, Rochester, MN, (4) Washington University School of Medicine, St. Louis, MO |
WE-C1000-GePD-F1-2 | Dosimetric Comparison of Several Radiotherapy Techniques in the Treatment of Scalp Cancer D Schulze*, H Zhang , Northwestern Memorial Hospital, Chicago, IL |
WE-C1030-GePD-F4-1 | Adaptive Cervix HDR Brachytherapy Using KV-CBCT S Wadi Ramahi*, C Constantinescu , N Jastaniyah , King Faisal Specialist Hospital & Research Center, Riyadh, Saudi Arabia |
WE-C1030-GePD-F4-2 | Dose Accumulation in Image-Guided HDR Brachytherapy Using Rigid Image Registration C Velten1*, R Yaparpalvi1 , S Mao2 , S Kalnicki1 , K Mehta1 , W Tome1,2 , (1) Montefiore Medical Center, Bronx, NY, (2) Albert Einstein College of Medicine, Bronx, NY |
WE-C1030-GePD-F4-3 | Effect and Accuracy of Heterogeneity Corrected Dose Calculation in HDR Brachytherapy E Schnell*, S Thompson , S Ahmad , T Herman , T De La Fuente Herman , University of Oklahoma Health Sciences Center, Oklahoma City, OK |
WE-C1030-GePD-F4-4 | Development and Implementation of a Script-Based Brachytherapy Plan Checker S Simiele*, X Chen , C Lee , B Rosen , J Mikell , J Moran , J Prisciandaro , Univ Michigan Medical Center, Ann Arbor, MI |
WE-C1030-GePD-F4-5 | Commissioning of Advanced Collapsed Cone Engine Algorithm for Brachytherapy J Swamidas*, S Parida , K Joshi , R Phurailatpam , S Panda , S Pradhan , Department of Radiation Oncology, ACTREC, Tata Memorial Center, Navi Mumbai, Maharashtra, India |
WE-C930-GePD-F6-6 | Real-Time Source and Plan Verification for High-Dose Rate (HDR) Brachytherapy Using Flat Panel Detector Y Rong1*, D Hernandez1 , J Zhang2 , S Benedict1 , M Lu2 , (1) University of California Davis Cancer Center, Sacramento, CA, (2) Varex Imaging Corp, Santa Clara, CA |
WE-HI-303-4 | Reliability of Doppler Blood Flow Evaluation of Neurovascular Bundle Vessels in Patients Receiving Prostate Radiotherapy X He*, X Yang , A Jani , J Sohn , P Patel , W Curran , T Liu , Emory University, Atlanta, GA |