MENU

Click here to

×

Are you sure ?

Yes, do it No, cancel

DISCLAIMER:
Entry of taxonomy/keywords during proffered abstract submission was optional.
Not all abstracts will appear in search results.

IM | IM/TH | TH | show all

Taxonomy: TH- External beam- photons: cyberknife

MO-C930-GePD-F7-1A Comprehensive Evaluation of the Performance of the CyberKnife M6: A One-Year Study of Daily QA
J Gersh1,2 , R Fulkerson3*, (1) Gibbs Cancer Center & Research Institute - Pelham, Greer , SC, (2) Spectrum Medical Physics, LLC, Greenville , SC,(3) RKF Consultants, Dundee, NY
SU-E-DBRA-6QA of Manipulator-Pointing Accuracy for CyberKnife Using a Cylindrical Diode Array
B Yang*, W Wong , W Lam , H GENG , C Kong , T Lee , K Cheung , S Yu , Hong Kong Sanatorium&Hospital, Hong Kong, Hong Kong
SU-H430-GePD-F4-1A New Methodology of Evaluation of Respiratory Motion Tracking Errors of CyberKnife Using a 2D Detector Array
B Yang*, T Chiu , M Law , K Tang , H GENG , W Lam , K Cheung , S Yu , Hong Kong Sanatorium & Hospital, Hong Kong, Hong Kong
SU-I-GPD-T-260Treatment Planning Comparison of CyberKnife and Linac-Based SBRT
J Yoon*, M Schwer , S Sharma , A Ju , East Carolina University, Greenville, NC
SU-I-GPD-T-380Implementation of the Electronic Portal Imaging Device for Daily CyberKnife Quality Assurance
L Wang*, A Lo , A Ho , Stanford University Cancer Center, Stanford, CA
SU-I-GPD-T-419On Possible Application of a Novel Bioabsorbable Implant for Accelerated Partial Breast Irradiation with CyberKnife
P Kosterin1*, C Ozhasoglu2 , S Jang3 , S Nagda4 , M Huq5 , (1) UPMC university of Pitsburgh Medical Center, Philadelphia, PA, (2) Shadyside Hospital, Pittsburgh, PA, (3) UPMC university of Pitsburgh Medical Center, Pittsburgh, PA, (4) Penn Radiation Oncology Pennsylvania Hospital, Philadelphia, Pennsylvania, (5) University of Pittsburgh Cancer Institute, Pittsburgh, PA
SU-I-GPD-T-432Simultaneously Boosting the Dose to the MpMRI and PSMA-PET Defined Intra-Prostatic Lesion Using Precision CyberKnife: A Feasibility Study
P Mavroidis1*, E Schreiber2 , B Thomann3 , C Zamboglou4 , I Sachpazidis5 , R Chen6 , A Grosu7 , S Das8 , D Baltas9 , (1) university North Carolina, Chapel Hill, NC, (2) university North Carolina, Chapel Hill, NC, (3) University of Freiburg, Freiburg, Breisgau, (4) University of Freiburg, Freiburg, Breisgau, (5) University of Freiburg, Freiburg, Breisgau, (6) UNC Health Care, Chapel Hill, NC, (7) University of Freiburg, Freiburg, Breisgau, (8) University of North Carolina, Chapel Hill, NC, (9) university Freiburg, Freiburg,
TH-AB-DBRA-1A Beam-Level Delivery Accuracy Study of the Robotic Image Guided Radiosurgery System Using a Scintillator/CCD Phantom
L Wang1*, B Nelson2 , (1) Stanford University Cancer Center, Stanford, CA, (2) Logos Systems International, Scotts Valley, CA
WE-C930-GePD-F4-4Evaluation of Out-Of-Field Dose Calculation Accuracy of CyberKnife System in Heterogeneous Phantom
J Yoon*, S Sharma , Y Feng , East Carolina Univ, Greenville, NC