DISCLAIMER:
Entry of taxonomy/keywords during proffered abstract submission was optional.
Not all abstracts will appear in search results.
Taxonomy: TH- External beam- photons: Quality Assurance - IMRT
MO-K-DBRA-4 | Feasibility of Using Machine Learning Techniques to Predict the Results of VMAT Patient-Specific QC Measurements DA Granville1*, JG Sutherland1,2,3 , DJ La Russa1,2,3 , (1) The Ottawa Hospital, Ottawa, ON, (2) The University of Ottawa, Ottawa, ON, (3) The Ottawa Hospital Research Institute, Ottawa, ON |
SU-F-209-5 | Use of Small 3D Radiochromic Dosimeters and a Motion Phantom for Dose Verification of Dynamic MLC Tracking Radiotherapy F Costa1*, M Menten1 , S Doran2 , J Adamovics3 , I Hanson1 , S Nill1 , U Oelfke1 , (1) The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London, (2) CRUK Cancer Imaging Centre, The Institute of Cancer Research, London, (3) Rider University, Lawrenceville, NJ |
SU-F-KDBRA2-7 | Secondary 3D Dose Verification for Online Adaptive Radiotherapy with MR-Linac G Chen*, J Zhang , X Li , Medical College of Wisconsin, Milwaukee, WI |
SU-H400-GePD-F4-6 | A Generalization of Gamma-Index-Analysis Methods to Evaluate the Agreement of Radiation Dose Distributions Varying by Three Or More Orders of Magnitude L Wilson*, W Newhauser , Louisiana State University, Baton Rouge, LA |
SU-H430-GePD-F4-2 | A Novel Mutual Information-Based Algorithm for IMRT/VMAT Quality Assurance B Ebrahimi*, R Rahimi Darabad , K Padgett , N Dogan , University of Miami, Miami, FL |
SU-H430-GePD-F4-6 | Multi-Institutional Analysis of Elekta Linear Accelerators Performance Using High-Resolution Log Files C Kabat1*, D Defoor2 , P Myers3 , N Papanikolaou1 , S Stathakis1 , (1) UT Health San Antonio, Texas, (2) Texas Oncology - Longview, Texas, (3) Baylor College of Medicine, Houston, TX |
SU-I-GPD-T-154 | VMAT Commissioning and Patient-Specific QA Using MatriXX Phantom A Bao*, P Geis , Y Zheng , G Pereira , N Kuc Petchler , J Elconin , M Machtay , University Hospitals Cleveland Medical Center, Cleveland, OH |
SU-I-GPD-T-178 | Effect of Detector Offset and Automatic Offset Correction On Portal Dosimetry for IMRT QA S Ferguson*, H Jin , S Ahmad , Oklahoma university Health Science Ctr., Oklahoma City, OK |
SU-I-GPD-T-179 | Development of An In-House Gamma Analysis Software for TomoTherapy Patient-Specific Quality Assurance (QA) J Kim1*, K Park2 , J Kim2 , H Lee2 , (1) Yonsei Caner Center, Seoul,(2) Yonsei University College of Medicine |
SU-I-GPD-T-182 | Modifying Portal Dosimetry Models to Match Portal Imager Response Improves Results for IMRT QA R Lalonde1*, M Huq1,2 , D Heron1,2 , (1) UPMC Hillman Cancer Center, Pittsburgh, PA, (2) University of Pittsburgh Cancer Institute, Pittsburgh, PA |
SU-I-GPD-T-184 | Prediction of IMRT/VMAT Quality Assurance Gamma Analysis Passing Rates Using Convolutional Neural Networks B Ziemer1*, Y Iterian2 , T Solberg1 , G Valdes1 , (1) University of California San Francisco, San Francisco, CA, (2) University of San Francisco, San Francisco, CA |
SU-I-GPD-T-188 | Predictive Gamma Passing Rate Based On Dose Uncertainty for Head-And-Neck and Prostate IMRT E Shiba1,2*, A Saito1 , M Tsuneda1,3 , M Furumi2 , K Yahara2 , T Ohguri2 , Y Murakami1 , T Nishio3 , Y Korogi2 , Y Nagata1 , (1) Hiroshima University, Hiroshima, Japan, (2) Hospital of the University of Occupational and Environmental Health, Fukuoka, Japan, (3) Tokyo Women's Medical University, Tokyo, Japan |
SU-I-GPD-T-194 | Impact of Different Treatment Planning Systems On Modulation Complexity for Prostate Volumetric Modulated Arc Therapy M Itano1*, K Motegi2 , S Kanai3 , S Shirasaki4 , H Tachibana5 , (1) ,,,(2) National Cancer Center, Kashiwa, Chiba, (3) Funabashi Municipal Medical Center, Funabashi, Chiba, (4) Funabashi Municipal Medical Center, Funabashi, Chiba, (5) National Cancer Center Hospital East, Kashiwa, |
SU-I-GPD-T-196 | Photon Beam Energy Dependence On IMRT QA for Brain Treatment Plan in Radiotherapy I Khan1 , B Tahir1 , M Rafique1 , T Iqbal1 , A Zahoor1,2 , J Rehman3 , K Iqbal2 , J Chow4*, (1) University of Gujarat, Gujrat, Pakistan, (2) SKMH&RC, Lahore, Pakistan, (3) BUITEMS, Quetta, Pakistan, (4) Princess Margaret Cancer Centre, Toronto, ON |
SU-I-GPD-T-200 | Investigating Causes to Unexplained Failures in IMRT QA A Uejo*, J Gagneur , E Clouser , Mayo Clinic Arizona, Phoenix, AZ |
SU-I-GPD-T-256 | Standardization of Sampling Radius Size for Treatment Planning Secondary Dose Calculation T Cui*, Z Ouyang , S Kost , L Qiu , M Sands , K Verdecchia , J Donaghue , P Xia , The Cleveland Clinic Foundation, Cleveland, OH |
SU-I-GPD-T-307 | RadCalc for Independent Dosimetric Validation of Plans Generated in Accuray Precision Treatment Planning System T Romaguera*, D Alvarez , S George , V Mishra , A Gutierrez , Miami Cancer Institute, Miami, FL |
SU-K-KDBRA1-1 | A Novel Learning Approach for Predicting MLC Positioning During Dynamic IMRT Delivery A Osman1*, N Maalej2 , K Jayesh3 , (1) American University of Beirut Medical Center, Beirut, Lebanon,(2) King Fahd University of Petroleum and Minerals, Dhahran, Saudi Arabia,(3) American Hospital Dubai, Dubai, UAE |
SU-L-KDBRA1-1 | A Machine Learning-Based Approach to Specify the Cause of Error in IMRT Patient Specific QA S Utsunomiya1*, M Sakai1 , H Koarai1 , T Takizawa2 , N Kushima2 , S Tanabe2 , H Aoyama3 , (1) Graduate School of Health Sciences, Niigata University, Niigata, Japan, (2) Niigata University Medical and Dental Hospital, Niigata, Japan, (3) Graduate School of Medical and Dental Sciences, Niigata University, Niigata, Japan |
TH-AB-KDBRA1-2 | A Method for Failure Prediction and Preventative Maintenance of Multi-Leaf Collimators Via Log Files D Moyer*, E Wolf , N Kumar , B McGill , M Lamba , D Ionascu , University of Cincinnati, Cincinnati, OH |
TU-C930-GePD-F3-4 | Using a QA Test System to Determine Mechanical Tolerance Limits of Linacs for Highly Complex Treatment Plans J Stroom*, A Taborda , S Vieira , C Greco , Champalimaud Centre for the Unknown, Lisbon, Lisbon |
TU-C930-GePD-F3-5 | A Deep Learning-Based Prediction Model for Gamma Evaluation in Patient-Specific Quality Assurance S Tomori1,2*, N Kadoya2 , Y Takayama2 , T Kajikawa2 , K Shima1 , K Narazaki1 , K Jingu2 , (1) National Hospital Organization Sendai Medical Center, Sendai, Japan(2) Tohoku University, Sendal, Japan |
WE-C930-GePD-F7-3 | Development of Novel Heterogeneous Anthropomorphic Head and Neck Phantom Using 3D Printer for IMRT Patient Specific Quality Assurance N Kadoya1*, K Abe1 , H Nemoto1 , K Sato2 , Y Ieko1 , K Ito1 , Y Takayama1 , T chiba1 , S Dobashi1 , K Takeda1 , K Jingu1 , (2) Tohoku University Graduate School of Medicine, Sendai, Japan,(2) Tohoku University Hospital, Sendai, Japan |
WE-FG-KDBRA1-8 | Independent Recalculation Outperforms Traditional Measurement-Based IMRT QA Methods in Detecting Unacceptable Plans S Kry*, M Glenn , D Branco , H Mehrens , A Steinmann , C Peterson , D Followill , MD Anderson Cancer Ctr., Houston, TX |