Taxonomy: TH- Brachytherapy: Calibration
SU-H330-GePD-F7-6 | A Plan Quality Assurance Method for HDR Breast Brachytherapy with Multi-Lumen Balloon Applicator M Napiwocki1 , Y Le2*, (1) Purdue University, West Lafayette, Indiana, (2) Indiana University- School of Medicine, Indianapolis, IN |
SU-I-GPD-P-52 | Calibration of 192Ir High Dose Rate Brachytherapysource Using Water Phantom L Yu , B Yang , x liu , T Pang , N Liu , b Li , t Dong , B Wang , z wang , J Qiu*, Peking Union Medical college Hospital, Beijing, China |
SU-I-GPD-T-2 | Surface Applicator-Based Electronic Brachytherapy Commissioning with a Focus On Individual Source Derived Performance Expectations T Denton1,2, (1) Associates in Medical Physics, LLC, Greenbelt, MD (2) The Norton Cancer Institute Radiation Center, Louisville, KY |
SU-I-GPD-T-4 | Quantitative HDR Afterloader Source Position QA Using Two MicroDiamond Detectors T Harris1*, R Cormack2 , I Buzurovic3 , D O'Farrell4 , J Bredfeldt5 , M Bhagwat6 , (1) Brigham & Women's Hospital, Boston, MA, (2) Brigham and Women's Hospital, Boston, MA, (3) Brigham & Women's Hospital, Harvard Medical School, Boston, MA, (4) Dana Farber Cancer Institute, Boston, MA, (5) Brigham and Women's Hospital, Boston, MA, (6) Dana Farber/Brigham and Women's Hospital, Boston, MA |
SU-I-GPD-T-20 | Filmless Method for HDR Brachytherapy Applicator Commissioning and Quality Assurance (QA) Using Fluoroscopic Images H Kang*, R Patel , M Mysz , J Roeske , Loyola university Medical Center, Maywood, IL |
TH-AB-KDBRB1-9 | Using Machine Learning to Develop a Novel Error Detection Algorithm for HDR Brachytherapy D Sterling*, E Ehler , University of Minnesota, Minneapolis, MN |
WE-AB-DBRA-2 | A Novel Source Tracking Method for Accurate and Comprehensive HDR Brachytherapy Quality Assurance Using Radiochromic Film Dosimetry S Aldelaijan1,2,3,4*, P Papaconstadopoulos2,3 , H Bekerat3 , J Schneider2,3 , J Seuntjens2,5 , I Buzurovic6 , S Devic2,3 , (1) Department of Biomedical Engineering, Montreal Neurological Institute, Montreal, Canada, (2) Medical Physics Unit, McGill University, Montreal, Canada, (3) Department of Radiation Oncology, Jewish General Hospital, Montreal, Canada, (4) Biomedical Physics Department, King Faisal Specialist Hospital & Research Centre, Riyadh, Saudi Arabia, (5) Department of Oncology, McGill University, Montreal, Canada (6) Department of Radiation Oncology, Dana-Farber/Brigham & Women's Cancer Center, Harvard Medical School, Boston, USA |
WE-AB-DBRA-8 | Microresolution Dosimetry System for Patient Specific Quality Assurance of Ocular Melanoma Eye Plaque Based Treatments S Pokhrel1*, A Wiles1 , T Knewtson1 ,Y Feng 1,2, M Ballo1,2 , E W Izaguirre1,2 , (1) university Tennessee Health Science Center,Methodist university Hospital, Memphis, TN., (2)West Cancer Center, Germantown, TN. |
WE-C1000-GePD-F4-4 | Validation of Acuros-Based Dose Distributions for Varian HDR Surface Applicator Set with Leipzig-Style Cones R Hunt*, D Cheek , J Molloy , D Pokhrel , University of Kentucky, Lexington, KY |
WE-C1000-GePD-F4-6 | Determination of Source Positions in HDR Applicators for Commissioning/QA Using An Image Plate Device, Raven QA I Bernstein*, B Yi , university of Maryland School Of Medicine, Baltimore, MD |