Taxonomy: IM- Optical : Registration
MO-C930-GePD-F1-1 | A New Registration Method Based On Surface Image Guided Radiation Therapy Jianfeng Zhao1,Pu Huang1,Lei Xing2, Steven Yi4, Bao Zhang3,Frank Meng4, Dengwang Li*1,(1) Shandong Normal University, Jinan, Shandong(2) Stanford University, School of Medicine, Stanford, California(3) Nanjing Hummingbird Hechnology co. Ltd, Nanjing, Jiangsu(4) Xyken LLC, Vienna, Virginia |
MO-C930-GePD-F5-1 | Assessment of the Quality and Accuracy of a Commercial Deformable Image Registration (DIR) Software I Jurkovic1*, N Papanikolaou2 , S Stathakis3 , N Kirby4 , P Mavroidis5 , (1) ,New Braunfels, TX, (2) University of Texas HSC SA, San Antonio, TX, (3) University Of Texas Health, San Antonio, TX, (4) University of Texas HSC SA, San Antonio, TX, (5) university North Carolina, Chapel Hill, NC |
MO-C930-GePD-F5-3 | Effect of Deformation Parameters On Deformable Image Registration Mapping of Simulated Pulmonary Ventilation Using a New Non-Rigid Ventilating Phantom S Miyakawa1*, H Tachibana2 , S Moriya3 , T Nishio1 , (1) Tokyo Women's medical University, Sinjuku, Tokyo, (2) National Cancer Center Hospital East, Kashiwa, ,(3) University of Tsukuba, Tsukuba, Ibaraki |
MO-C930-GePD-F5-5 | Evaluation of the Dose Delivery Accuracy and Its Dependence On Imaging Modality and Deformable Image Registration Algorithm in Prostate Cancer Patients J Hammers1*, S Pirozzi2 , D Lindsay3 , O Kaidar-Person4 , N Papanikolaou5 , S Stathakis6 , R Chen7 , S Das8 , P Mavroidis9 , (1) ,Chapel Hill, NC, (2) MIM Software Inc., Cleveland, OH, (3) University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, (4) Rambam Health Care Campus, Haifa, ,(5) Ut Health San Antonio, San Antonio, TX, (6) University Of Texas Health, San Antonio, TX, (7) UNC Health Care, Chapel Hill, NC, (8) University of North Carolina, Chapel Hill, NC, (9) university North Carolina, Chapel Hill, NC |
MO-C930-GePD-F5-6 | MR to CBCT Registration Accuracy for IGRT On the Gamma Knife ICON B Morris*, W Duggar , A Fatemi , C Yang , University of Mississippi Med. Center, Jackson, MS |
SU-E-KDBRB1-3 | Comparison of the Localization Accuracy in Conventional and Ultra-Low Dose CT Fluoroscopy - A Simulation Study M Wagner*, F Lee , L Hinshaw , P Laeseke , T Szczykutowicz , M Speidel , C Mistretta , University of Wisconsin, Madison, WI |
SU-E-KDBRC-4 | Use of Vasculature Information in Biomechanical Model-Based Registration of Longitudinal Liver Cancer CT Scans G Cazoulat*, B Chaudhury , B Anderson , M Zaid , D Elganainy , EJ Koay , K Brock , The University of Texas MD Anderson Cancer Center, Houston, TX |
SU-F-202-6 | A Method to Improve Landmark Pair Positional Accuracy for Image Registration Verification D Yang*, Y Fu , X Chang , H Li , Washington University School of Medicine, St. Louis, MO |
SU-F-209-1 | Hydrogel Spacer Or Gas Release Rectal Balloon, a Comparative Study of Prostate Intra-Fraction Motion in Proton Therapy Z Su*, J Wu , K Mund , N Mendenhall , R Nichols , B Hoppe , C Bryant , R Henderson , Z Li , University of Florida, Jacksonville, FL |
SU-F-KDBRC-1 | Dose Volume Histogram Comparisons as a Quality Assurance Metric for Deformable Image Registration K Kainz*, S Lim , G Chen , X Li , Medical College of Wisconsin, Milwaukee, WI |
SU-H300-GePD-F4-6 | Improving Patient Positioning Reproducibility During Head and Neck Re-Simulation for Re-Treatment Using a Surface Mapping System S Liu1*, P Dubrowski2 , Y Fu3 , D Yang4 , Y Yang5 , A Yu6 , (1) Stanford university Scool of Medicine, Stanford, CA, (2) Stanford University, Palo Alto, CA, (3) Washington University in Saint Louis, St. Louis, MO, (4) Washington University in St Louis, St Louis, MO, (5) Stanford University Cancer Center, Stanford, CA, (6) Stanford University Cancer Center, Stanford, CA |
SU-H330-GePD-F5-2 | Intra-Fraction Motion Monitoring for Spine SBRT Patients Using KV Cone-Beam Projections D Markel*, D Letourneau , H Keller , N Becker , D Shultz , Princess Margaret Hospital, Toronto, ON |
SU-I-GPD-J-1 | Influence of Varying Degrees of CBCT Image Artifacts On 3D-3D Image Registration Accuracy for Cranial Target Localization in Proton Therapy Using a Commercial Auto Registration Algorithm J George*, J Bennouna , W Hsi , M Hall , R Kotecha , M Fagundes , M Mehta , A Gutierrez , Miami Cancer Institute, Miami, FL |
SU-I-GPD-J-16 | Coping with Obese Patient: Cone Beam CT for Image Guided Radiotherapy F.Q. Guo1, 2*, H Chen1, 2 , Z Chen1, 2, R Nath1, 2, (1) Yale University School of Medicine, New Haven, CT, (2) Yale New Haven Hospital, New Haven, CT |
SU-I-GPD-J-22 | Feasibility of Virtual CT for Adaptive Radiotherapy Using CT-To-CBCT Deformable Image Registration for Treatment of Head and Neck Malignancies Y Nakaguchi*, |
SU-I-GPD-J-33 | Assessment of Deformable Image Registration for Stomach Dose Accumulation in Pancreatic Cancer Radiotherapy: A Simplified Phantom Based QA and Clinical Performance Evaluation F Zhu*, G Ren , W Wu , Q Qin , F Zhu , Y Wang , T Xia , Department of Radiation Oncology, PLA General Airforce Hospital., Beijing, Beijing |
SU-I-GPD-J-34 | Validation of Accuracy in Deformable Image Registration by Use of Three-Dimensional Phantom M Kobayashi1*, N Hayashi2 , K Egami3 , K Yasui2 , (1) Graduate School of Health Sciences, Fujita Health University, (2) School of Health Sciences, Fujita Health University, (3) Daido Hospital, Department of Radiology, |
SU-I-GPD-J-35 | Evaluation of Diffeomorphic Demons Algorithm for Deformable Image Registration Using Virtual Phantom R Reiazi*, R Mohammadi , SR Mahdavi , Iran University of Medical Sciences, Tehran, Tehran |
SU-I-GPD-J-36 | Evaluation of the Deformable Registration of Two Commercial Software Regarding the Estimation of Inter-Fractional Dose Delivery Accuracy of Prostate VMAT Plans N Papanikolaou1*, J Hammers2 , S Stathakis3 , D Baltas4 , R Chen5 , S Das6 , P Mavroidis7 , (1) Ut Health San Antonio, San Antonio, TX, (2) ,Chapel Hill, NC, (3) University Of Texas Health, San Antonio, TX, (4) university Freiburg, Freiburg, ,(5) UNC Health Care, Chapel Hill, NC, (6) University of North Carolina, Chapel Hill, NC, (7) university North Carolina, Chapel Hill, NC |
SU-I-GPD-J-37 | Biomechanical Modeling of Compressed Breast Tissue F Liu*, E Klein , Warren Alpert School of Medicine at Brown University, Providence, RI |
SU-I-GPD-J-39 | Evaluation of Uncertainty and PTV Margins in Image-Guided Target-Based Patient Positioning for Prostate Cancer T Hirose1,2*, H Arimura2 , J Fukunaga1 , Y Umezu1 , S Ooga2 , T Sasaki2 , (1) Kyushu University Hospital, Fukuoka, Fukuoka, (2) Kyushu University, Fukuoka, Fukuoka |
SU-I-GPD-J-40 | Quantitative Assessment of 6D Image Registration Software Using CBCT Provided by Two Manufacturers Y Shibayama*, S Takarabe , J Fukunaga , T Hirose , Kyushu University Hospital, Fukuoka, Fukuoka |
SU-I-GPD-T-82 | Comparison Study of the Spatial Deviation of Different Bladder Volumes in Prostate Radiotherapy with Pelvic Lymph Node (PLN) X Yang*, Z Lu , F Zhao , L Bu , S Yan , Department of Radiation Oncology, the First Affiliated Hospital, College of, Hangzhou, Zhejiang |
SU-I-GPD-T-454 | Deformable Image Registration Performances On Registering Sequential 18F-FDG PET/CT Images Obtained From a Growing Tumor: An Animal Study S Chen*, A Qin , D Zhou , T John , K Buelow , D Yan , William Beaumont Hospital, Royal Oak, MI |
TH-CD-KDBRC-2 | Use of a Rigidity Penalty to Improve CT to MRI Image Registration E Boehnke*, A Santhanam , C Gao , K Sheng , UCLA School of Medicine, Los Angeles, CA |
TH-CD-KDBRC-5 | PET/CT-Ultrasound Registration for PET-Determined Prostate Brachytherapy S Sultana*, D Song , J Lee , Johns Hopkins University, Department of Radiation Oncology and Molecular Radiation Sciences, Baltimore, MD |
TH-CD-KDBRC-7 | Automatic Registration of 2D MR Cine Images for Swallowing Motion Estimation J Yang*, H Bahig , A Mohamed , S Frank , K Hutcheson , C Fuller , MD Anderson Cancer Center, Houston, TX |
TU-AB-205-6 | Auto-Contour Based Treatment Alignment of Prostate Patients Y Shen1*, L Qiu2 , K Stephans2 , C Shah2 , A Godley2 , (1) Cleveland State University, Cleveland, OH, (2) Cleveland Clinic, Cleveland, OH |
TU-C1030-GePD-F9-4 | Innovative Cumulative Dose Calculation for Deformable Organs at Risk in Abdominal Stereotactic Body Radiation Therapy J Barbiere*, R Teboh Forbang , G Beninati , A Ndlovu , Hackensack University Medical Center, Hackensack, New Jersey |
TU-C1030-GePD-F9-6 | Evaluation of a Commercial DIR Platform for Contour Propagation in Prostate Cancer Patients Treated with IMRT/VMAT J Hammers1*, S Pirozzi2 , D Lindsay3 , O Kaidar-Person4 , N Papanikolaou5 , S Stathakis6 , R Chen7 , S Das8 , P Mavroidis9 , (1) ,Chapel Hill, NC, (2) MIM Software Inc., Cleveland, OH, (3) University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, (4) Rambam Health Care Campus, Haifa, ,(5) Ut Health San Antonio, San Antonio, TX, (6) University Of Texas Health, San Antonio, TX, (7) UNC Health Care, Chapel Hill, NC, (8) University of North Carolina, Chapel Hill, NC, (9) university North Carolina, Chapel Hill, NC |
TU-I345-GePD-F2-2 | Development of Digital Thoracic Phantoms Based On Physiological Modeling of Respiratory Motion From Hyperpolarized Gas Tagging MRI Technique I Duarte1*, T Cui2 , W Miller3 , F Yin1 , J Cai1,4 , (1) Duke University Medical Center, Durham, NC, (2) Cleveland Clinic, Cleveland, OH, (3) University of Virginia, Charlottesville, Virginia, (4) The Hong Kong Polytechnic University, Kowloon, Yau Tsim Mong |
TU-I345-GePD-F5-2 | Development of Vertebral Body Phantom Mimicking Spinal Fixation for Stereotactic Body Radiotherapy M Kanda1*, R Suganami1 , S Kito1 , Y Nakajima1 , M Yamasaki1 , T Furuya1 , T Okano2 , A Yamashita1 , K Karasawa1 , (1) Tokyo Metropolitan Komagome Hospital, Tokyo, Japan, (2) Tokyo Metropolitan Tama Medical Center, Tokyo, Japan |
TU-I345-GePD-F5-4 | Localization Methods of the Gamma Knife Icon and Effects of Image Scan Parameters W Duggar*, C Yang , University of Mississippi Med. Center, Jackson, MS |
TU-I345-GePD-F6-6 | Clinical Knowledge-Based Estimation of Target Position Displacements Using Machine Learning Architectures in Prostate Intensity Modulated Radiotherapy Y Kai1,2*, H Arimura2 , K Ninomiya2 , M Maruyama1 , Y Nakaguchi1 , Y Shimohigashi1 , (1) Kumamoto University Hospital, Honjou, Chuo-ku, Kumamoto, Japan (2) Kyushu University, Maidashi, Higashi-ku, Fukuoka, Japan |
WE-AB-KDBRC-2 | Longitudinal Assessment of 4DCT-Derived Ventilation Change Following Radiation Therapy TJ Patton1*, SE Gerard2 , W Shao2 , GE Christensen2 , JM Reinhardt2 , AM Baschnagel1 , JE Bayouth1 , (1) University of Wisconsin - Madison, Madison, WI, (2) The University of Iowa, Iowa City, IA |
WE-C1000-GePD-F2-4 | Multi-Vendor Evaluation of Inter-CBCT Protocol Registration Variations M Trager*, K Mooney , Thomas Jefferson University Hospital, Philadelphia, PA |
WE-C1000-GePD-F2-5 | Online Assessment of Dose Changes in Head and Neck Radiotherapy Without Dose Re-Computation Using Deformable Image Registration J Vickress1*, J Battista1,2 , R Barnett1,2 , S Yartsev1,2, (1) University of Western Ontario Department of Medical Biophysics, London, ON, (2) London Regional Cancer Program, London, Ontario, |
WE-C1000-GePD-F8-2 | Accuracy of Template Matching in the Localization of a Vertebral Body During SBRT Dose Delivery D Lovelock1*, S Lim1 , A Fontanella1 , H Mostafavi2 , J Mechalakos1 , A Wild1 , J Yamada1 , (1) Mem Sloan-Kettering Cancer Ctr, New York, NY, (2) Varian Medical Systems, Palo Alto, CA |
WE-C1030-GePD-F8-1 | A Comparison of Deformable Registration Techniques for Pre and Post-Treatment Cholangiocarcinoma CT Images A Sen*, B Anderson , G Cazoulat , M Zaid , B Chaudhury , D Elganainy , E Koay , K Brock , UT MD Anderson Cancer Center, Houston, TX |
WE-C930-GePD-F5-5 | Performance Evaluation of 3D Model-Based Global-To-Local Deformable Surface Registration of Multi Organs in Prostate Cancer M Nakamura1*, M Nakao2 , H Hirashima1 , H Iramina1 , T Mizowaki1 , (1) Kyoto University, Graduate School of Medicine, Kyoto , (2) Kyoto University, Graduate School of Informatics, Kyoto |
WE-J-KDBRC-4 | Developing a Physical Motion Modeling Technique to Account for Deformation in the Head and Neck Region Caused by Patient Posture Changes B Guo*, P Xia , The Cleveland Clinic Foundation, Cleveland, OH |