MENU

Click here to

×

Are you sure ?

Yes, do it No, cancel

DISCLAIMER:
Entry of taxonomy/keywords during proffered abstract submission was optional.
Not all abstracts will appear in search results.

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # | show all

Keywords: setup verification
MO-C930-GePD-F6-4Study On Interfractional Range Reduction by Range-Based Registration Using Daily CBCT for Pelvic and Abdominal Sarcoma Patients Treated by Intensity-Modulated Proton Therapy
W Yao*, R Windmueller , V Harikumar , O Ates , M Krasin , St. Jude Children's Research Hospital, Memphis, TN
MO-I345-GePD-F2-1A Novel Approach to Verify Air Gap and SSD for Proton Radiotherapy Using Surface Imaging
X Wang*, C Ma , K Nie , R Davis , N Yue , Y Zhang , Department of Radiation Oncology, Rutgers-Cancer Institute of New Jersey, Rutgers-Robert Wood Johnson Medical School, New Brunswick, NJ
SU-I-GPD-J-53Surface Guided Radiotherapy Decreases the Uncertainty in Breast Cancer Patient Setup
S Ceberg1*, A Mannerberg2 , L Berg3 , A Edvardsson4 , C Thornberg5 , S Alkner6 , M Kugele7 , (1) Medical Radiation Physics, Department of clinical sciences, Lund University, and Department of Hematology, Oncology and Radiation Physics, Skane University Hospital, Lund, Sweden (2) Department of Hematology, Oncology and Radiation Physics, Skane University Hospital, Lund, Sweden (3) Department of Hematology, Oncology and Radiation Physics, Skane University Hospital, Lund, Sweden (4) Medical Radiation Physics, Department of clinical sciences, Lund University, Sweden (5) Department of Hematology, Oncology and Radiation Physics, Skane University Hospital, Lund, Sweden (6) Department of Hematology, Oncology and Radiation Physics, Skane University Hospital, Lund, Sweden (7) Medical Radiation Physics, Department of clinical sciences, Lund University, and Department of Hematology, Oncology and Radiation Physics, Skane University Hospital, Lund, Sweden
SU-I-GPD-T-154VMAT Commissioning and Patient-Specific QA Using MatriXX Phantom
A Bao*, P Geis , Y Zheng , G Pereira , N Kuc Petchler , J Elconin , M Machtay , University Hospitals Cleveland Medical Center, Cleveland, OH
SU-I-GPD-T-249A Method for Setup Margin Calculation Including Translational and Rotational Uncertainties in External Radiotherapy
A Perez-Rozos*, L de la Pena , A Diez de los Rios , Radiologia y Medicina Fisica, Oftalmologia y Otorrinolaringologia, Universidad de Malaga, Malaga, Spain
TU-I345-GePD-F6-1A Direct Comparison of Commercial Surface Imaging and Radiographic Imaging for SRS Alignment in Phantom
D Wiant*, H Liu , Q Shang , T Hayes , J Maurer , B Sintay , Cone Health Cancer Center, Greensboro, NC
TU-I345-GePD-F6-3Do We Still Need Tattoos?
M Roof*, J Chavez , H Liu , B Sintay , D Wiant , Cone Health Cancer Center, Greensboro, NC
WE-C930-GePD-F9-2Low-Resource Vendor-Independent Coplanar Patient Clearance Verification Tool
M Trager*, P Charpentier , Thomas Jefferson University Hospital, Philadelphia, PA