MO-AB-KDBRA1-5 | Guiding Novel Flat Panel Detector Designs with Direct Measurements of Depth-Dependent Scintillator Gain and Blur A Howansky*, A.R. Lubinsky , W Zhao , Stony Brook University, Stony Brook, NY |
MO-AB-KDBRA1-8 | Scintillator Target Imaging Provides Accurate Remote Multi-Site Surface Dosimetry I Tendler1*, P Bruza1 , J Andreozzi1 , B Williams2,3 , L Jarvis2,3 , B Pogue1,2 , D Gladstone1,2,3 , (1)Thayer School of Engineering, Dartmouth College, Hanover, NH (2) Department of Medicine, Geisel School of Medicine, Dartmouth College, Hanover, NH (3)Norris Cotton Cancer Center, Dartmouth-Hitchcock Medical Center, Lebanon, NH |
MO-I345-GePD-F9-1 | Characterizing a High-Density Glass Scintillator for Proton Imaging A Zieser1*, U Akgun2 , Y Onel3 , D Wang4 , (1) University of Iowa, Iowa City, IA, (2) Coe College, Cedar Rapids, IA, (3) University of Iowa, Iowa City, IA, (4) University of Iowa, Iowa City, IA |
SU-E-DBRA-1 | Development of a Compact Time-Resolved 2-Dimensional Dosimetry System W Cheon1*, H Jung2, M Lee1 , J Lee1 , S Kim3 , S Cho3 , Y Han4 , (1) SAIHST, Sungkyunkwan University, Seoul, (2) University of Texas Southwestern Medical Center, Texas (3) Samsung medical center, Seoul, (4) Sungkyunkwan University School of Med, Seoul |
SU-H330-GePD-F8-2 | Non-Invasive Positron Detector to Monitor the Input Function in PET V Turgeon1*, G Kertzscher2 , S Abbasi Nejad Enger1 , (1) McGill University , Montreal, QC, (2) Aarhus University Hospital, Aarhus, Denmark |
SU-I-GPD-T-211 | Two-Dimensional Scintillation Dosimetry Using a Low-Cost Liquid Scintillator and a CMOS Detector of a Commercial Digital Camera F Biagioni, J Pavoni*, Faculty of Philosophy, Sciences and Letters at Ribeirao Preto - University of Sao Paulo |
SU-I-GPD-T-366 | Validation of Linac Small-Field Commissioning with a Commercial Plastic Scintillator Detector J Van Schelt*, A Templeton, D Bernard, G Cifter, J Turian, Rush University Medical Center, Chicago, IL |
SU-K-209-1 | A High-Performance 3 Points Plastic Scintillator Dosimeter for HDR Brachytherapy: Conception, Development and Characterization H Linares Rosales1,2*, L Archambault1,2 , S Beddar3 , L Beaulieu1,2 , (1) CHU de Quebec-Universite Laval, Quebec, Quebec, (2) Departement de physique and University Laval Cancer Research Centre, Quebec, Canada, (3) UT MD Anderson Cancer Center, Houston, TX |
TH-CD-DBRA-9 | Fiber Optic Dosimeters Based On Silver-Only Coated Hollow Waveguides for Radiation Therapy Dosimetry A Darafsheh*, Washington University School of Medicine, St. Louis, MO |
TH-EF-202-2 | A Novel High Quantum Efficiency MV X-Ray Detector for Image-Guided Radiotherapy J Liu1*, A Teymurazyan2 , Y Xu3 , G Pang4 , (1) Ryerson University, Toronto, Ontario, (2) University of Regina, Regina, Saskatchewan, (3) Ryerson University, Toronto, Ontario, (4) TSRCC, Toronto, ON |
TU-C1030-GePD-F4-3 | Characterization of Plastic Scintillator W2 Detector in Small Field Dosimetry P Galavis*, L Hu , I Das , NYU Langone Health, New York, NY |
TU-C930-GePD-F3-3 | In Vivo, Time Resolved, Dose Monitoring for Pre-Clinical Research Applications L Archambault1*, F Therriault-Proulx1 , J Langevin2 , J Galarneau2 , J Fradette1 , (1) CHU de Quebec - Universite Laval, Quebec city, QC, (2) Cegep de Ste-Foy, Quebec City, QC |
TU-C930-GePD-F4-3 | Quantifying Nanoparticle Radioluminescence and "rational Design" of Nanotherapeutics for X-PDT D Cooper1*, J Capobianco2, J Seuntjens1, (1) Medical Physics Unit, McGill University, Montreal, QC, (2) Concordia University, Montreal, QC |
TU-K-207-8 | Towards Time Resolved 3D Dosimetry in MRI-Linacs: Scintillation Images Surrogate Dose Distribution with High Accuracy P Bruza1*, J Andreozzi1 , O Green2 , J Cammin2 , D Gladstone1,3 , B Pogue1 , (1) Dartmouth College, Hanover, NH, (2) Washington University, School of Medicine, St. Louis, MO, (3) Dartmouth-Hitchcock Medical Center, Lebanon, NH |
TU-K-KDBRC-7 | Using Dual Step Wedge and 2D Scintillator to Achieve Highly Precise and Robust Proton Range Quality Assurance W Deng*, W Liu , D Robertson , M Bues , T Sio , S Keole , J Shen , Mayo Clinic Arizona, Phoenix, AZ |
WE-C1000-GePD-F3-3 | Quantifying the Impact of High-Z Doping On Plastic Scintillator Response H Nusrat1*, G Pang1,2 , A Sarfehnia1,2 , (1) Ryerson University, Toronto, ON, (2) Sunnybrook Health Science Center, Toronto, ON |
WE-C1000-GePD-F3-5 | Volumetric Scintillation Signals Separation Using the Multispectral Formalism E Cloutier* , L Archambault, L Beaulieu, Centre Hospitalier university de Quebec, Quebec, QC |
WE-C930-GePD-F3-5 | Validation of Inhomogeneity Correction in Small Field L Hu*, P Galavis , I Das , NYU Langone Medical Center, New York, NY |
WE-J-KDBRA1-5 | Plastic Scintillators as In-Vivo Dosimeters for Photons and Electrons in External Beam Radiation Therapy: Angular Dependence of Response E Avila Ruiz1*, T Monajemi2 , (1) Dalhousie University, Halifax, NS, (2) Nova Scotia Cancer Centre, Halifax, NS |