DISCLAIMER:
Entry of taxonomy/keywords during proffered abstract submission was optional.
Not all abstracts will appear in search results.
MO-J430-CAMPUS-F3-5 | Improvement On the Sensitivity and Dose Linearity of the 3D Radiochromic Polyurethane by Adding Yellow Pigment J Cho*, J Kim , C Choi , H An , S Kang , M Kim , S Lee , J Park , Seoul National University Hospital, Seoul, SEOUL |
SU-E-DBRA-3 | Investigation of the Thermal Characteristics of a Reusable Radiochromic Gel Dosimeter K Ono1*, K Fujino1 , S Hayashi2 , K Hioki3 , M Miyazawa4 , Y Akagi1 , Y Hirokawa1 , (1) Hiroshima Heiwa Clinic, Hiroshima, JP, (2) Hiroshima International University, Hiroshima, JP, (3) Hiroshima University Hospital, Hiroshima, JP, (4) R-TECH. INC, Tokyo, JP |
SU-H400-GePD-F4-3 | Homogeneous and Heterogeneous 3D Dosimeters for IMRT End-To-End Testing in a Pre-Clinical MR-Linac B McDonald1,2*, H Lee1, Y Roed1,3, Muhammad Akram1,4, G Ibbott1, (1) Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, (2) The University of Texas MD Anderson Cancer Center UTHealth Graduate School of Biomedical Sciences, Houston, TX, (3) Department of Physics, University of Houston, Houston, TX, (4) Department of Physics, The Islamia University of Bahawalpur Pakistan |
SU-I-GPD-T-3 | A Verification of High-Dose-Rate Brachytherapy Dose Distributions for Prostate Cancer with a VIPET Polymer Gel Dosimeter K Eguchi1*, Y Watanabe2 , S Mizukami2 , T Maeyama3 , S Hayashi4 , T Gomi2 , (1) Kitasato University Graduate School of Medical Sciences, Sagamihara, Kanagawa, Japan, (2) School of Allied Health Sciences, Kitasato University, Sagamihara, Kanagawa, Japan, (3) School of Science, Kitasato University, Sagamihara, Kanagawa, Japan, (4) Faculty of Health Sciences, Hiroshima International University, Higashihiroshima, Hiroshima, Japan, |
SU-I-GPD-T-193 | Current Limitations and Emerging Solutions for Quality Assurance (QA) of Single-Isocenter VMAT Treatment of Multiple Brain Metastases (MBM) P Zygmanski1*, M Wagar1 , M Maryanski2 , F Hacker1 , (1) Brigham & Women's Hospital, Boston, MA,(2) MGS Research, Madison, CT |
SU-I-GPD-T-202 | Three-Dimensional Polymer Gel Dosimetry Using An Onboard 0.35 T Magnetic Resonance Imaging Scanner B Maraghechi , H Gach , D Yang , H Li*, Washington University School of Medicine, St Louis, MO |
SU-I-GPD-T-321 | Evaluation of 3D Dosimetry System with Clear View Radiochromic Hydrogel K Jordan1*, K Dekker2 , R Hazarika3 , (1) London Regional Cancer Program, London, ON, (2) University of Western Ontario, London, ON, (3) University of Waterloo, Waterloo, ON |
SU-I-GPD-T-377 | Development of the 4D Phantom Using the 3D Gel Dosimetry for Liver SBRT: A Preliminary Study S Noh1*, M Lee2 , K Yoon3 , J Kwak4 , B Cho5 , S Kim6 , H Kim7 , C Jeong8 , (1) ,,,(2) Asan Medical Center, Seoul, SEOUL, (3) Asan Medical Center, Seoul, SEOUL, (4) Asan Medical Center, Seoul, ,(5) Asan Medical Center, Seoul, ,(6) Asan Medical Center, Seoul, SEOUL, (7) Asan Medical Center, Seoul, Seoul, (8) Asan Medical Center, Seoul, Seoul |
TH-AB-DBRA-4 | Deformable Anthropomorphic Abdominal Phantom for the Validation of Deformable Dose Accumulation Algorithms and Intrafractional Motion Management Systems C Matrosic*, I Marsh , B Palmer , J Hull , B Bednarz , W Culberson , University of Wisconsin, Madison, WI |
TU-I345-GePD-F7-5 | Comparison of Multiple Pulse Sequences for MRI Based Gel Dosimetry B Maraghechi , H Gach , D Yang , H Li*, Washington University School of Medicine, St Louis, MO |
WE-C1000-GePD-F7-5 | The Potential of Polymer Gel for 3D Dosimetry in Magnetic Resonance-Image Guided Radiotherapy Y Roed1,2*, L Pinsky1 , G Ibbott2 , (1) University of Houston, Houston, TX, (2) UT MD Anderson Cancer Center, Houston, TX |
WE-C1030-GePD-F2-3 | Nuclear Overhauser Enhancement (NOE) Magnetic Resonance Imaging for Polymer Gel Dosimetry A Quevedo1,2*, G Luo3 , M Price3 , Z Zu2 , P Nicolucci1 , J Gore2 , (1) University of Sao Paulo, Ribeirao Preto, Sao Paulo, (2) Vanderbilt University Institute of Imaging Science, Nashville, Tennessee, (3) Department of Radiation Oncology, Vanderbilt University Medical Center, Nashville, Tennessee |
WE-FG-KDBRA1-11 | Nanotechnology Based Gel Dosimeter for in Vivo Use in Skin Brachytherapy A Rapchak1*, S Dutta2 , A Sadeghi3 , S Inamdar4 , T Sokolowski5 , C Page6 , S Sapareto7 , K Rege8 , K Subramaniam9 , (1) Banner MD Anderson Cancer Center, Gilbert, AZ, (2) Arizona State University, Tempe, AZ, (3) Banner MD Anderson Cancer Center, Gilbert, AZ, (4) Arizona State University, Tempe, AZ, (5) Banner MD Anderson Cancer Center, Gilbert, AZ, (6) Banner MD Anderson Cancer Center, Gilbert, AZ, (7) Banner - University Medical Center Phoenix, Phoenix, AZ, (8) Arizona State University, Tempe, AZ, (9) Arizona State University, Tempe, AZ |