MENU

Click here to

×

Are you sure ?

Yes, do it No, cancel

DISCLAIMER:
Entry of taxonomy/keywords during proffered abstract submission was optional.
Not all abstracts will appear in search results.

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # | show all

Keywords: dose response
MO-C930-GePD-F8-6Tumour Signal Enhancement Volume Increase in DCE-MRI After Single Fraction SBRT of Early Stage Breast Cancer
M Mouawad1,2,3*, H Biernaski2 , M Brackstone3 , M Lock3 , A Kornecki4 , O Shmuilovich4 , I Nachum4 , F Prato1,2 , R Thompson1,2 , S Gaede1,2,3 , N Gelman1,2,3 , (1) Western University, London, Ontario, Canada (2) Lawson Health Research Institute, London, Ontario, Canada, (3) London Regional Cancer Program, London, Ontario, Canada, (4) St. Joseph's Health Center, London, Ontario, Canada
MO-E115-GePD-F2-3Effect of Lung SBRT Fractionation On Feature Variability of Longitudinal Cone-Beam CT Radiomics
R Geng1*, K Lafata2 , F Yin3 , (1) Duke University, Durham, NC, (2) Duke University, Durham, NC, (3) Duke University Medical Center, Durham, NC
MO-E115-GePD-F5-1Convolutional Neural Networks for Identifying Correlation Between Dose Patterns Associated with Poor Survival and Early Local Recurrence After Metastatic Liver SBRT
B Ibragimov1*, Y Yuan3, D Toesca2 , D Chang4 , A Koong5 , L Xing6 , (1) ,,,(2) Stanford University, Stanford, California, (3) Stanford University, Stanford, CA, (4) Stanford University, Stanford, CA, (5) The University of Texas MD Anderson Cancer Center, Houston, TX, (6) Stanford Univ, School of Medicine, Stanford, CA
SU-I-GPD-T-77Dosimetric and Radiobiological Fitting of Xerostomia Outcome Data 12 Months After Radiation Therapy for Head and Neck Tumors
A Kubli1*, D Fried2 , W Mendenhall3 , N Sheets4 , R Green5 , S Das6 , L Marks7 , B Chera8 , P Mavroidis9 , (1) ,Durham, NC, (2) UNC Health Care, Chapel Hill, NC, (3) University of Florida, Gainesville, FL, (4) UNC Health Care, Chapel Hill, NC, (5) University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, (6) University of North Carolina, Chapel Hill, NC, (7) UNC School of Medicine, Chapel Hill, NC, (8) University of North Carolina, Chapel Hil, NC, (9) university North Carolina, Chapel Hill, NC
SU-I-GPD-T-80Updates to Radiotherapy Outcomes Estimator (ROE) for Protocol Comparison and Display of Clinical Constraints
A Iyer*, A Jackson , A Apte , M Thor , A Fontanella , J Oh , J Deasy , Memorial Sloan-Kettering Cancer Center, New York, NY
SU-I-GPD-T-83Tumor Size Can Have An Impact On TheOutcomes of Epidemiological Studies On Second Cancers After Radiotherapy
U Schneider1,2*, L Walsh2 , W Newhauser3 , (1) Klinik Hirslanden, Zurich, Zurich, (2) University Zurich, Zurich, ZH, (3) Louisiana State University, Baton Rouge, LA
SU-I-GPD-T-110Preliminary Research On Calibration of 2D Detector of Dose Response with Co-60 Applied to Proton Beams
Y.C. Lin1*, S.Y. Cai2 , M.C. Yuan3 , Y.W. Tsai4 , F.X. Chang5 , T.S. Duh6 , C.C. Chiang Hsieh7 , A.E. Chen8 , (1) Health Physics Division, Institute of Nuclear Energy Research, Taoyuan city, Taiwan(R.O.C.), (2) National Central University, Taoyuan City, Taiwan(R.O.C.), (3) Institute of Nuclear Energy Research, Taoyuan City, Taiwan(R.O.C.), (4) National Central University, Taoyuan City, Taiwan(R.O.C.), (5) Academia Sinica, Taipei, Taiwan(R.O.C.), (6) Institute of Nuclear Energy Research, Taoyuan City, Taiwan(R.O.C.), (7) Taiwan Power Company, Taipei, Taiwan(R.O.C.), (8) National Central University, Taoyuan City, Taiwan(R.O.C.)
SU-I-GPD-T-313Predicting Photon Dosimetry of EBT3 Gafchromic Films to Improve Accurate Dosimetry Using Machine Learning Method
YU-SHEN Lin*, E-DA hospital, Kaohsiung, Taiwan (R.O.C.)
SU-I-GPD-T-326Response of a NanoDot OSLD System in Megavoltage Photon and Electron Beams
K Hoshida1*, F Araki2 , T Ohno3 , Y Shimohigashi4 , (1) Kumamoto University,Kumamoto, ,(2) Kumamoto University, Kumamoto, ,(3) Kumamota University, Kumamota, ,(4) Kumamoto University Hospital, ,Kumamoto
SU-K-DBRA-2Dosimetric and Radiobiological Fitting of Dysphagia Outcome Data 12 Months After Radiation Therapy for Head and Neck Tumors
A Kubli1*, D Fried2 , W Mendenhall3 , N Sheets4 , R Green5 , S Das6 , L Marks7 , B Chera8 , P Mavroidis9 , (1) ,Durham, NC, (2) UNC Health Care, Chapel Hill, NC, (3) University of Florida, Gainesville, FL, (4) UNC Health Care, Chapel Hill, NC, (5) University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, (6) University of North Carolina, Chapel Hill, NC, (7) UNC School of Medicine, Chapel Hill, NC, (8) University of North Carolina, Chapel Hil, NC, (9) university North Carolina, Chapel Hill, NC
TH-AB-DBRB-1Optimal Energy of Virtual Monoenergetic Imaging From Dual-Energy CT for Target Delineation and Radiation Response Assessment
G Noid1*, D Schott1 , T Schmidt2 , A Tai1 , X Li1 , (1) Medical College of Wisconsin, Milwaukee, WI, (2) Marquette University, Milwaukee, WI,
TH-AB-KDBRC-11Adaptive Dose Painting by Number Planning Using a Novel Object of Dose Prescription Function Derived From Multiple 18F-FDG PET/CT Images
S Chen*, D Zhou , J Liang , D Krauss , D Yan , William Beaumont Hospital, Royal Oak, MI
TU-D-KDBRA1-2Fitting NTCP Models to SBRT Dose and Carotid Blowout Syndrome Data
P Mavroidis1*, J Grimm2 , M Cengiz3 , S Das4 , G Yazici5 , G Ozyigit6 , (1) university North Carolina, Chapel Hill, NC, (2) Johns Hopkins University, Baltimore, MD, (3) Hacettepe University, Faculty of Medicine, Ankara, Ankara, (4) University of North Carolina, Chapel Hill, NC, (5) Hacettepe University, Faculty of Medicine, Ankara, Ankara, (6) Hacettepe University, Faculty of Medicine, Ankara, Ankara
TU-K-KDBRC-3Analysis of Radiation-Induced Visual Toxicity in Meningioma Treatment: Protons Vs. Photons
C Peeler*, D Grosshans , R Mohan , K Tran , S McGovern , A Bishop , D Mirkovic , UT MD Anderson Cancer Center, Houston, TX
WE-C1030-GePD-F4-5Using Multivariate Dose-Response Models to Help Select Radiotherapy Prescriptions
E Bendau1 , A Iyer2 , M Thor2 , A Apte2 , A Hotca3 , E Yorke2 , A Rimner2 , J Deasy2 , A Jackson2* , (1) The City College of New York, New York, NY (2) Memorial Sloan Kettering Cancer Center, New York, NY (3) Drexel University, Philadelphia, PA
WE-C1030-GePD-F9-5Lung Dose Threshold for Interstitial Pneumonitis for Patients Undergoing Total Body Irradiation
A Nalichowski1*, M Snyder2 , J Rakowski3 , D Ionascu4 , I Chetty5 , R Fisher6 , J Burmeister3 , (1) Karmanos Cancer Institute, Detroit, MI, (2) Beaumont Hospital, Royal Oak, MI, (3) Wayne State university School of Medicine, Detroit, MI, (4) University of Cincinnati, Cincinnati, OH, (5) Henry Ford Health System, Detroit, MI, (6) Fisher Statistics, Lincoln, NE,