MENU

Click here to

×

Are you sure ?

Yes, do it No, cancel

DISCLAIMER:
Entry of taxonomy/keywords during proffered abstract submission was optional.
Not all abstracts will appear in search results.

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # | show all

Keywords: TLDs
MO-I345-GePD-F1-2Calibration of a Thermoluminescent Dosimeter Worn Over Leadaprons in Fluoroscopy Guided Procedures
A Quintero1,2 , G Patino2 , A Soriano3 , J Palma3 , J Vilar3 , M Pujades3 , N Llorca3 , F Ballester4 , J Vijande4*, C Candela3 , (1) Grupo de Fisica Nuclear Aplicada y Simulacion, Universidad Pedagogica y Tecnologica de Colombia (UPTC), Tunja (Boyaca), 150003, Colombia (2) Department of Atomic, Molecular and Nuclear Physics, Universitat de Valencia (UV),Burjassot (Valencia) 46100, Spain (3) Centro Nacional de Dosimetria (CND), Instituto Nacional de Gestion Sanitaria, Valencia 46009, Spain (4) Unidad Mixta de Investigacion en Radiofisica e Instrumentacion Nuclear en Medicina (IRIMED), Instituto de Investigacion Sanitaria La Fe (IIS-La Fe)-Universitat de Valencia (UV) and IFIC (CSIC UV), Burjassot 46100, Spain
SU-I-GPD-T-118Linear Energy Transfer Measurement System Development with TLD-100
CH Sung1*, HH Chen2,3 , YC Lin4 , SW Wu2 , HC Huang2,3 , SL Chang5 , HY Tsai5,6 , (1) Department of Medical Imaging and Radiological Science, College of Medicine, Taoyuan City, Taiwan, (2) Department of Radiation Oncology, Chang Gung Memorial Hospital, Linkou, Taoyuan City, Taiwan, (3) Graduate Institute of Clinical Medical Sciences, College of Medicine, Chang Gung University, Taoyuan City, Taiwan, (4) Health Physics Division, Institute of Nuclear Energy Research, Taoyuan City, Taiwan, (5) Institute of Nuclear Engineering and Science, National Tsing Hua University, Hsinchu City, (6) Department of Engineering and System Science, National Tsing Hua University, Hsinchu City, Taiwan
SU-I-GPD-T-163Estimate Eye Lens Dose by Using Personal Dose Equivalent (HP (10)) and Dose-Area Product (DAP) in Interventional Procedures
P Hu1*, j wang1 , W Hu1 , H Liu2 , 1 Fudan University Shanghai Cancer Center 2 Institute of Radiation Medicine, Fudan University, Shanghai
SU-I-GPD-T-208Surface Dose Measurements in Head and Neck Helical Tomotherapy Using Ultrathin Thermoluminesences Dosimeter
S Srisuwan*, P Tangboonduangjit , R Worawongsakul , S Sakulsingharoj , S Piasanthia , Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Rajathevi, Bangkok
SU-I-GPD-T-214Clinical Evaluation of the Feasibility of in Vivo Measurements with MOSFET
B Hu1*, B King2 , M Huq3 , (1) UPMC Cancer Centers, Erie, PA, (2) The Regional Cancer Cemter, Erie, PA, (3) University of Pittsburgh Cancer Institute, Pittsburgh, PA
SU-K-KDBRA1-4Effect of a 1.4 T Magnetic Field On TLDs with a 6MV Medical Linear Accelerator
W Culberson1*, W Culberson2 , C Hammer3 , R Kapsch4 , U Ankerhold5 , (1) university of Wisc Madison, Department of Medical Physics, School of Medicine and Public Health, Madison, WI, (2) university of Wisc Madison, Department of Medical Physics, School of Medicine and Public Health, Madison, WI, (3) University of Wisconsin Madison, Madison, Wisconsin, (4) Physikalisch Technische Bundesanstalt, Braunschweig, Germany (5) Physikalisch Technische Bundesanstalt, Braunschweig, Germany
WE-C930-GePD-F1-5Effective Energy in a CT Phantom Obtained From the Thermoluminescent Glow Curve of TLD-300
JA Rojas-Lopez1 , E Lopez-Pineda1 , CA Reynoso-Mejia2 , ME Brandan1*, (1) Universidad Nacional Autonoma de Mexico, Inst de Fisica, Mexico City, Mexico,(2) Inst Nac de Neurologia y Neurocirugia, Mexico City, Mexico
WE-C930-GePD-F7-6Energy Response of Thermoluminescent Dosimeters in 3D-Printed Mouse Phantoms for Kilovoltage X-Ray Beams
N Viscariello*, C Hammer , K Kunugi , L DeWerd , University of Wisconsin-Madison, Madison, WI
WE-C930-GePD-F9-1Evaluation of Dose Reduction by Using Superflab Boluses at Out-Of-Field Region
J Yoon1*, Y Xie2 , R Zhang2,3 , (1) East Carolina University, Greenville, NC, (2) Louisiana State University, Baton Rouge, LA, (3) Mary Bird Perkins Cancer Center, Baton Rouge, Louisiana