MENU

Click here to

×

Are you sure ?

Yes, do it No, cancel

DISCLAIMER:
Entry of taxonomy/keywords during proffered abstract submission was optional.
Not all abstracts will appear in search results.

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # | show all

Keywords: Small Fields
MO-E115-GePD-F3-5Unsettled Issues, Distance and Depth of Measurements of Output Factor(fclin, Fmsr) in Small Field Dosimetry
I Das1*, P Galavis1 , L Hu1 , P Francescon2 , (1) NYU Langone Medical Center, New York, NY, (2)Ospedale Di Vicenza, Vicenza, Italy
SU-H300-GePD-F7-3Comparison of Collapsed Cone Convolution Superposition and Monte Carlo Dose Calculations for Spine SBRT Dose
H Parenica*, J Rembish , D Saenz , K Rasmussen , N Kirby , Z Shi , Y Li , M Fakhreddine , R Crownover , C Ha , N Papanikolaou , S Stathakis , UT Health San Antonio, San Antonio, TX
SU-I-GPD-T-96Accuracy of Eclipse Proton Pencil-Beam Algorithm for Small Brain Targets Using Mevion S250 Proton Therapy System
K Depew*, S Ahmad , H Jin , Oklahoma university Health Science Ctr., Oklahoma City, OK
SU-I-GPD-T-361Commissioning of Brainlab IPlan- and Elements-Based Stereotactic Radiosurgery Utilizing Both MLC and Aktina Cone Solutions On An Elekta Agility Platform
N Marsh*, M Maynard , J Dugas , G Schimke , H Wu , Willis-Knighton Medical Center, Shreveport, LA
SU-I-GPD-T-366Validation of Linac Small-Field Commissioning with a Commercial Plastic Scintillator Detector
J Van Schelt*, A Templeton, D Bernard, G Cifter, J Turian, Rush University Medical Center, Chicago, IL
SU-I-GPD-T-418A Phantom-Based Analysis of Small Field Monitor Unit Calculation Agreement Between the Eclipse Treatment Planning System and RadCalc Software
S Ellefson*, E Clouser, Mayo Clinic Arizona, Phoenix, AZ
SU-J400-CAMPUS-F3-3Reversing the Bias Against Diodes: Instantaneous Dose Rate Corrections to Improve Scanning Performance
S Graves*, D Hyer , University Of Iowa, Iowa City, IA
TH-EF-KDBRA1-2An Investigation of Patient Plan-Specific Correction Factors for Three Ion Chambers in Collapsed Composite IMRT Treatments Using a PTW MicroDiamond and Monte Carlo Simulations
V Desai*, Z Labby , W Culberson , university of Wisc Madison, Madison, WI
TU-C1030-GePD-F4-3Characterization of Plastic Scintillator W2 Detector in Small Field Dosimetry
P Galavis*, L Hu , I Das , NYU Langone Health, New York, NY
TU-GH-KDBRA1-4Optimization of a Microbeam Collimator for Use On the Small Animal Radiation Research Platform
N Esplen*, C Johnstone, L Chergui, M Bazalova-Carter, University of Victoria, Victoria, BC
WE-C1030-GePD-F7-4Small Static Fields: Real-Time Assessment of the Accuracy of a Treatment Planning System (TPS) Calculated Dose with a Step-And-Shoot Method
G Biasi1*, N Hardcastle12 , M Petasecca1 , S Guatelli1 , A Rozenfeld1 , T Kron123 , (1) University of Wollongong, Wollongong, NSW, Australia, (2) Peter MacCallum Cancer Centre, Melbourne, Victoria, Australia, (3) Sir Peter MacCallum Cancer Institute, University of Melbourne, Victoria, Australia
WE-C1030-GePD-F7-6Variation of Detector Specific Output Correction Factorsfor Small Fields From Different Linacs/collimation Systems
E Gershkevitsh1*, N Mendez2 , B Casar3 , (1) North Estonia Regional Hospital, Tallinn, ,(2) Oncology Institute of Ljubljana, Ljubljana, (3) Oncology Institute of Ljubljana, Ljubljana,
WE-C930-GePD-F3-5Validation of Inhomogeneity Correction in Small Field
L Hu*, P Galavis , I Das , NYU Langone Medical Center, New York, NY
WE-FG-KDBRA1-2Accuracy of Real-Time Large and Small Beam Measurements From An MR-Linac Using Cherenkov Imaging Technique in a Water Tank
J Andreozzi1*, P Bruza1 , J Cammin2 , D Gladstone3,1 , B Pogue1 , O Green2 , (1) Dartmouth College, Hanover, NH, (2) Washington University, School of Medicine, St. Louis, MO, (3) Dartmouth-Hitchcock Medical Center, Lebanon, NH
WE-FG-KDBRA1-5Cherenkov Emission-Based Photon and Electron Beam Dosimetry
Y Zlateva1*, I El Naqa2 , J Seuntjens3 , (1) McGill University, Montreal, QC, (2) University of Michigan, Ann Arbor, MI, (3) McGill University, Montreal, QC