MO-I345-GePD-F2-3Comparison of Beam Characteristics and Organ Doses for a Proton Gantry-Mounted CBCT System Modelled with MCNP6 and GATE
O Ardenfors1*; 2, T Henry1; 2, I Gudowska1; 2, G Poludniowski3 , A Dasu4 , (1) Stockholm University, Stockholm, Sweden, (2) Karolinska Institutet, Stockholm, Sweden, (3) Karolinska University Hospital, Stockholm, Sweden, (4) The Skandion Clinic, Uppsala, Uppsala
MO-I345-GePD-F3-5Validation and Application of a Fast Monte Carlo Algorithm for Assessing the Clinical Impact of Approximations in Analytical Dose Calculations for Proton Therapy
S Huang1*, K Souris2 , S Li1 , M Kang3 , G Janssens4 , A Lin1 , E Garver1 , C Ainsley1 , Y Xiao1 , L Lin1 , (1) University of Pennsylvania, Philadelphia, PA, (2) UCL, Woluwe, Brussels, (3) Georgetown University Hospital, Washington, DC, (4) Ion Beam Applications SA, Louvain-la-neuve, Walloon Brabant,
MO-I345-GePD-F4-1A Virtual Machine Source Model for Monte Carlo Simulations of the Mevion S250 Proton System
J Yuan, Federick Jesseph, Chee-Wai Cheng, Rodney Ellis and Mitchell Machtay University Hospitals Case Medical Center, Cleveland, OH
MO-J430-CAMPUS-F3-4Implementation of Heterogeneous Computing Methods and Development of An EGSnrc-Based External Beam Dose Engine for Validating a GPU-Based Monte Carlo Code, ARCHER
D Adam1*, H Lin2 , T Liu2 , P Caracappa2 , X Xu2 , B Bednarz1 , (1) University of Wisconsin-Madison, Madison, WI, (2) Rensselaer Polytechnic Institute, Troy, NY
SU-E-DBRB-1A Mathematical Deconvolution Formulation for Superficial Dose Distribution Measurement by Cerenkov Light Dosimetry
E Brost*, Y Watanabe , University of Minnesota, Minneapolis, MN
SU-E-KDBRA1-6On Monte Carlo Deliverable Pareto Surface Navigation for Photon IMRT and Mixed Beam Radiotherapy
S Mueller1*, F Mueller1 , M K Fix1 , S Tessarini1 , T Risse1 , O Elicin1 , K Loessl1 , M F M Stampanoni2 , P Manser1 (1) Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern, Switzerland (2) Institute for Biomedical Engineering, ETH Zurich and PSI, Villigen, Switzerland
SU-E-KDBRA2-1A Method for Measuring LET of Hadron Beams
S Bello , S Luan*, M Holzscheiter , University of New Mexico, Alburquerque, NM
SU-F-205-1Organ Dose Heterogeneity in Chest and Abdominopelvic CT Scans for a Population of Adult and Pediatric Phantoms: A Virtual Clinical Trial Study
J Fenoli*, S Sharma , E Abadi , P Segars , E Samei , A Kapadia , Duke University Medical Center, Durham, NC
SU-F-DBRA-1Development of a TEM Image-Based Cellular Geometry Model for Geant4 Monte Carlo Simulations of GNP-Mediated Dose Enhancement/radiosensitization
S Jayarathna*, S Krishnan , S H Cho , The University of Texas MD Anderson Cancer Center, Houston, TX
SU-F-KDBRA1-1Applying a Saturation Correction to the Microdosimetric Kinetic Model Prediction for the Relative Biological Effectiveness of a Carbon Ion Beam
M Newpower*, D Patel , L Bronk , F Guan , D Grosshans , U Titt , R Mohan , UT MD Anderson Cancer Center, Houston, TX
SU-F-KDBRA1-3Biological Dose Enhancement Using Lipiodol in Liver SBRT After TACE
D Kawahara1*, H Nakano2 , S Ozawa3 , A Saito3 , T Kimura3 , M Tsuneda1 , K Hioki4 , H Masuda4 , Y Ochi4 , T Nakashima4 , Y Ohno4 , Y Murakami3 , Y Nagata3 , (1) 1 Radiation Therapy Section, Department of Clinical Support, Hiroshima University Hospital, 1-2-3 Kasumi, Minami-ku, Hiroshima City, Hiroshima, Japan,(2) Hiroshima Heiwa Clinic, State of the Art Treatment Center, 1-31 Kawara-machi, Naka-ku, Hiroshima City, Hiroshima, Japan, (3) Hiroshima University, Hiroshima, Hiroshima, (4) Department of Radiation Oncology, Institute of Biomedical & Health Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima City, Hiroshima, Japan
SU-H300-GePD-F7-1A Comprehensive Robustness Test Based On Fast Monte Carlo Simulations for PBS Proton Therapy
K Souris*, A Barragan Montero , E Sterpin , J Lee , UCL, Belgium
SU-H300-GePD-F7-2A Monte Carlo Based Treatment Planning System for Optical Image Guided Small Animal Irradiation
K Xu1,2, J Shi1 , A Keyvanloo1 , T S Udayakumar1 , W Zhao1,2 , N Dogan1,2 , A Pollack1 , Y Yang1,2 * , (1) University of Miami Miller School of Medicine, Miami, FL, (2) University of Miami, Coral Gables, FL
SU-H300-GePD-F7-3Comparison of Collapsed Cone Convolution Superposition and Monte Carlo Dose Calculations for Spine SBRT Dose
H Parenica*, J Rembish , D Saenz , K Rasmussen , N Kirby , Z Shi , Y Li , M Fakhreddine , R Crownover , C Ha , N Papanikolaou , S Stathakis , UT Health San Antonio, San Antonio, TX
SU-H330-GePD-F5-5Scatter Correction for Conebeam CT Using Deep Residual Convolutional Neural Network
C Yang*, Y Jiang , P Yang , L Zhang , Y Xue , L Xu , T Niu , Zhejiang University, Hangzhou, Zhejiang
SU-H330-GePD-F6-4Scatter Corrected Cone-Beam CT for Radiomics in Stereotactic Body Radiation Therapy: A Feasibility Study
Y Jiang*, L Xu , C Yang , Y Xue , P Yang , T Niu , Zhejiang University, Hangzhou, Zhejiang
SU-H330-GePD-F7-2Dosimetry of Beta-Emitting Brachytherapy Sources for Age-Related Macular Degeneration
Mark J Rivard1*, Kyle T Mohney2 , Toby S Welles2 , Paul T Finger2, (1) Rhode Island Hospital / Warren Alpert Medical, Providence, RI, (2) LV Liberty Vision Corp., Portsmouth, NH
SU-I-GPD-P-48New Conversion Factors Relating Dose -Length Product to Effective Dose for Chest CT Scan with TCM
Y Huang*, H Liu , W Zhuo , Institute of Radiation Medicine, Fudan University, Shanghai, Shanghai
SU-I-GPD-T-31Evaluation of Inter-Seed Attenuation in LDR Brachytherapy Using Artificial Neural Network (ANN)
K Bayati1 , S sina1,2 , R Faghihi1,2*, (1) Nuclear engineering department, Shiraz University, Shiraz, Iran (2) Radiation Research Center, Shiraz University, Shiraz Iran,
SU-I-GPD-T-36Obtaining the Phase Space of An Electronic Brachytherpy Equipment for Surfaces Treatments Through Monte Carlo Simulations
C Valdes*1,2, Yury Niatsetski3, J Perez-Calatayud1,4, J Vijande1, F Ballester1, (1) University of Valencia, Valencia, Spain, (2) Centro Oncologico de Antofagasta, Antofagasta, Chile, (3) Elekta Brachyhtherapy, Veenendal, The Neetherlands, (4) La Fe Hospital, Valencia, Spain
SU-I-GPD-T-42Dosimetric Impact of Different Radionuclides On Eye Plaque Brachytherapy
P Aryal1*, M Rivard2 , (1) University of Maryland School of Medicine, Baltimore, MD, (2) Department of Radiation Oncology, Alpert Medical School of Brown University, Providence, RI
SU-I-GPD-T-49Monte Carlo Simulation of In Vivo Verification for Small Aperture Electron Radiotherapy
K Li*, Associates In Medical Physics, Lanham, MD
SU-I-GPD-T-55Electron Monte Carlo Comparison to Hand Calculations and Phantom Measurements
K Chu*, V Potari , R Rostock , M DeLuca , Western Connecticut Health Network, Danbury Hospital, Danbury, CT
SU-I-GPD-T-79Generating Fetal Doses for Pregnant Survivors of the Atomic Bombs in Hiroshima and Nagasaki
C Paulbeck*, W Bolch , university Florida, Gainesville, FL
SU-I-GPD-T-98Evaluation of Proton Therapy Dose Calculations in a Simple Geometrical Static Lung Phantom
D Branco*, P Taylor , S Kry , D Mirkovic , D Followill , MD Anderson Cancer Ctr., Houston, TX
SU-I-GPD-T-103Comparison of Dose Calculation for Brain, Lung, Pelvis and Abdomen Targets with Monte Carlo Simulation and Eclipse Pencil Beam Algorithm
M Prusator*, L Muller , S Ahmad , Y Chen , Oklahoma university Health Science Ctr., Oklahoma City, OK
SU-I-GPD-T-108TOPAS Monte Carlo Modeling and Calculation for Passive Scattering Proton Therapy Commissioning and TPS Dosimetric Evaluation: A Preliminary Study
H Liu1,2*, X Shen2 , R Slopsema2 , M Ho2 , Z Li2 , X Pei1 , X Xu1,3 , (1) University of Science and Technology of China, Hefei, Anhui, China. (2) The university of Florida Health Proton Therapy Instit., Jacksonville, FL.(3) Rensselaer Polytechnic Inst., Troy, NY.
SU-I-GPD-T-110Preliminary Research On Calibration of 2D Detector of Dose Response with Co-60 Applied to Proton Beams
Y.C. Lin1*, S.Y. Cai2 , M.C. Yuan3 , Y.W. Tsai4 , F.X. Chang5 , T.S. Duh6 , C.C. Chiang Hsieh7 , A.E. Chen8 , (1) Health Physics Division, Institute of Nuclear Energy Research, Taoyuan city, Taiwan(R.O.C.), (2) National Central University, Taoyuan City, Taiwan(R.O.C.), (3) Institute of Nuclear Energy Research, Taoyuan City, Taiwan(R.O.C.), (4) National Central University, Taoyuan City, Taiwan(R.O.C.), (5) Academia Sinica, Taipei, Taiwan(R.O.C.), (6) Institute of Nuclear Energy Research, Taoyuan City, Taiwan(R.O.C.), (7) Taiwan Power Company, Taipei, Taiwan(R.O.C.), (8) National Central University, Taoyuan City, Taiwan(R.O.C.)
SU-I-GPD-T-115Development of the Monte Carlo Simulation Platform Using Geant4 for Designing Particle Therapy Beam Nozzle
J Shin*, J Chun , H Lee , J Kim , Yonsei University College of Medicine, Seoul, Seoul
SU-I-GPD-T-117Optimization of Treatment Plan Verification Calculations for Proton Spot-Scanning System Using TOPAS Monte Carlo Code at Shared High Performance Computing Cluster
P Fakhriddin*, V Moskvin , F Xie , M Kaluarachchi , A Faught , T Merchant , St. Jude Children's Research Hospital, Memphis, TN
SU-I-GPD-T-123Convergent Pencil Beam Modeling with Monte Carlo Transport Codes for Synchrotron Based Intensity Modulated Proton Beam System Model in Eclipse Treatment Planning System
V Moskvin*, L Zhao , J Farr , St. Jude Children's Research Hospital, Memphis, TN
SU-I-GPD-T-143Monte Carlo Simulation of the First Hyperscan Treatment Nozzle
M Kang1*, R Cessac2 , D Pang1 , (1) Georgetown University Hospital, Washington, DC, (2) Mevion Medical Systems, Littleton, MA
SU-I-GPD-T-158A Correction of the Gamma Test for Monte Carlo Dose Distributions Comparison
M Cohilis*, E Sterpin , J Lee , K Souris , Universite Catholique de Louvain, Woluwe, Brussels
SU-I-GPD-T-231Photon Energy Spectral Analysis in the Mucosal Dose with and Without the Flattening Filter: A Monte Carlo Study
J Chow1*, A Owrangi2 , (1) Princess Margaret Cancer Centre, Toronto, ON, (2) UT Southwestern Medical Center, Dallas, TX
SU-I-GPD-T-232Monte Carlo Verification of Jaws-Only IMRT Dose Distributions From Prowess Panther System On Octavius 4D Phantom
T Tai1,3 , N Son2 , T Loan3 , L Oanh4 , J Chow5*, (1) Dongnai General Hospital, Bien Hoa, Vietnam, (2) Chi Anh Medical Technology Co.,Ltd., Ho Chi Minh, Vietnam, (3) University of Science, Ho Chi Minh, Vietnam, (4) Nguyen Tat Thanh University, Ho Chi Minh, Vietnam, (5) Princess Margaret Cancer Centre, Toronto, ON
SU-I-GPD-T-234Evaluation of the RBE Enhancement Owing to Gold by Calculating the DSB Rate - A Monte Carlo Study
Y CHIANG1*, C Tung2 , C Lee3 , C Chu4 , T Chao5 , (1) Chang Gung University, Guishan Dist, Taoyuan City, (2) Chang Gung University, Guishan Dist, Taoyuan City, (3) Chang Gung University, Guishan Dist., Taoyuan City, (4) Institute of Nuclear Energy Research, Longtan District, Taoyuan City, (5) Chang Gung University, Guishan Dist., Taoyuan City
SU-I-GPD-T-235Monte Carlo Modeling of the ELEKTA VersaHD with the Agility Collimator
H Parenica*, N Kirby , K Rasmussen , D Saenz , M Fakhreddine , N Papanikolaou , S Stathakis , UT Health San Antonio, San Antonio, TX
SU-I-GPD-T-236Monte Carlo Calculation of Radiation Yield,
DWO Rogers*, Carleton Univ, Ottawa, ON
SU-I-GPD-T-237Monte Carlo Studies of Quasi-Monochromatic and Monochromatic X-Ray Sources and Heavy Element Nanovehicles for Enhancing Radiation Therapy
M Westphal*, S Nahar , A Pradhan , The Ohio State University, Columbus, OH
SU-I-GPD-T-238Two Beam Modulation Approaches Comparison: A Monte Carlo Study for MLC and Clinical Compensator Used for IMRT
John Zhai1,2*, (1) Simon Cancer Center, Radiation Oncology Department, Indiana University School of Medicine, Indianapolis, IN. (2) Tennessee Medical Physics, LLC, Nashville, TN
SU-I-GPD-T-239Validation of Scientific RT's SciMoCa Monte Carlo Dose Calculation Algorithm
Carl Stanhope1,2*, Douglas G Drake1, Markus Alber3,4 , Matthias Sohn3, Di Yan1, (1) William Beaumont Hospital, Royal Oak, MI, USA (2) Wayne State University, Detroit, MI, USA (3) Scientific RT GmbH, Munich, Germany (4) Heidelberg University Hospital, Heidelberg, Germany
SU-I-GPD-T-240Validating Monaco Beam Models for a Versa HD Linac
J Snyder*, D Hyer , R Flynn , D Wang , University of Iowa Hospitals and Clinics, Iowa City, IA
SU-I-GPD-T-326Response of a NanoDot OSLD System in Megavoltage Photon and Electron Beams
K Hoshida1*, F Araki2 , T Ohno3 , Y Shimohigashi4 , (1) Kumamoto University,Kumamoto, ,(2) Kumamoto University, Kumamoto, ,(3) Kumamota University, Kumamota, ,(4) Kumamoto University Hospital, ,Kumamoto
SU-I-GPD-T-345Monte Carlo Study of a Novel Compensator for IMRT in Low and Middle Income Countries
D Toomeh1*, S Gadoue2 , N Fong1 , G Subrahmanyam3 , M Tamilarasan3 , K Govindarajan4 , E Ford1 , (1) University of Washington, Seattle, WA, (2) Loma Linda University Medical Center, Loma Linda, CA, (3) Panacea Medical Technologies, Bangalore, India, (4) PSG Hospital, Coimbatore, India
SU-I-GPD-T-404Is Monte Carlo Necessary for IntraCranial Stereotactic Radiosurgery?
J Rembish1*, D Saenz1 , P Mavroidis2 , R Crownover1 , P Myers3 , N Papanikolaou1 , S Stathakis1 , (1) Ut Health San Antonio, San Antonio, Texas,(2) university North Carolina, Chapel Hill, NC, (3) Baylor College of Medicine, Houston, TX
SU-I-GPD-T-440High Energy Neutron Shielding for High Yield Proton PCB Exposure: A Monte Carlo Study
S Zimmerman*, D Moyer , E Wolf , D Ionascu , M Lamba , University of Cincinnati, Cincinnati, OH
SU-I-GPD-T-446Dependence of DNA Energy Deposition Enhancement On the Irradiation Geometry for a Gold Nanoparticle
K Kujanpaa1 , J Chow2*, (1) University of Toronto, Toronto, ON, (2) Princess Margaret Cancer Centre, Toronto, ON
SU-I-GPD-T-447Imaging Contrast Enhancement On Nanoparticle Addition: A Monte Carlo Evaluation
F Albayedh1 , J Chow2*, (1) Ryerson University, Toronto, ON, (2) Princess Margaret Cancer Centre, Toronto, ON
SU-I-GPD-T-453Investigation of Small Field Electron Beams for Preclinical Irradiation
D Parsons*, X Gu , S Stojadinovic , M Chen , S Jiang , W Lu , UT Southwestern Medical Center, Dallas, TX
SU-J400-CAMPUS-F2-2Lineal Energy Distributions for Secondary Radiations From Gold Nanoparticles Irradiated by Different Energy Photon Beams
H Kim1*, W Sung1, 2 , S Ye1, 2 , (1) Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, Korea (2) Biomedical Research Institute, Seoul National University Hospital, Seoul, Korea
SU-J400-CAMPUS-F3-2Monte Carlo Track Structure Simulations of Radiation Induced Damage in a Fractal Globule Full Nuclear DNA Model
A McNamara1*, J Ramos-Mendez2 , J Perl3 , B Faddegon2 , H Paganetti1 , J Schuemann1 , (1) Massachusetts General Hospital & Harvard Med. Sch., Boston, MA, (2) University of California San Francisco, UCSF Helen Diller Family Comprehensive Cancer Center, San Francisco, CA, (3) SLAC National Accelerator Laboratory, Menlo Park, CA.
SU-K-209-7Simulated Performance of a Multi-Source Conformal Superficial Brachytherapy Device
B Rogers1*, C Ferreira2 , J Lawrence3 , E Ehler4 , A Erdman5 , (1) University of Minnesota - Twin Cities, Minneapolis, MN, (2) University of Minnesota, Minneapolis, MN, (3) University of Minnesota - College of Veterinary Medicine, St. Paul, Minnesota, (4) University of Minnesota, Minneapolis, MN, (5) University of Minnesota - Twin Cities, Minneapolis, Minnesota
SU-K-DBRA-7Research On the Radiosensitization Ability of FePt Nanopaticles Cluster with Monte Carlo Simulation
P Qi*, z Dai , H Peng , wuhan university, Wuhan, Hubei
SU-KL-DBRB-1BEST IN PHYSICS (IMAGING): Optimization of a Table-Top X-Ray Fluorescence Computed Tomography (XFCT) System
C Dunning*, M Bazalova-Carter , university of Victoria, VCH040, Victoria, BC
SU-KL-DBRB-2An Image-Based Mouse Model for Geant4 Monte Carlo Simulations of Multimodal Imaging with Benchtop X-Ray Fluorescence CT (XFCT) and Micro-CT
S Jayarathna*, M F Ahmed , S H Cho , The University of Texas MD Anderson Cancer Center, Houston, TX
SU-L-207-1Estimation of Effective Imaging Dose and Excess Absolute Risk of Secondary Cancer Incidence for 4D-CBCT Using Monte Carlo Simulation
Y Yuasa1*, T Shiinoki1 , R Onizuka2 , K Fujimoto1 , H Hanazawa1 , (1) Yamaguchi University, Ube, Yamaguchi, (2) Yamaguchi University Hospital, Ube, Yamaguchi,
SU-L-KDBRA2-1Assessment of Proton Pencil Beam Scanning (PBS) Treatment Quality Using 4D Monte Carlo Simulation in Lung Cancer
S Li1*, S Huang1 , K Souris3 , L Lin1 , (1) University of Pennsylvania, Philadelphia, PA (2) UCL, Woluwe, Brussels
TH-CD-202-2CT Dose Calculation Via a Fast, Deterministic Boltzmann Transport Equation Solver: Validation Against AAPM Task Group 195 Monte Carlo Reference Data
A Wang1*, A Maslowski1 , T Wareing1 , T Schmidt2 , J Star-Lack1 , (1) Varian Medical Systems, Palo Alto, CA, (2) Marquette University, Milwaukee, WI
TH-CD-202-4Comprehensive Implementation of Patient-Informed Organ Dose Estimation for Adult, Pediatric and Pregnant Patients in Clinical Computed Tomography
W Fu*, P Segars , K Choudhury , A Kapadia , J Wilson , F Ria , E Samei , Duke University Medical Center, Durham, NC
TH-CD-202-7NCICTX: An Organ Dose Calculator for CT Patients with Different Body Sizes
C Lee1*, J Liu2 , J Yao3 , R Summers4 , L Folio5 , (1) National Cancer Institute, Rockville, MD, (2) National Institutes of Health, Bethesda, Maryland, (3) National Institutes of Health, Bethesda, Maryland, (4) National Institutes of Health, Bethesda, Maryland, (5) National Institutes of Health, Bethesda, Maryland
TH-CD-202-8Organ and Effective Dose Conversion Factors for Body CT Scans of Arbitrary AnatomicalCoverage Based On a Realistic Patient Model
J Bell1*, X Li2 , F Dong2 , A Primak3 , P Segars4 , B Herts2 , (1) ,Lakewood, OH, (2) The Cleveland Clinic, Beachwood, OH, (3) Siemens Medical Solutions USA, Inc., Cleveland, Ohio, (4) Department of Radiology, Duke University Medical Center, Durham, North Carolina
TH-CD-202-10Examining the Effects Tube Current Modulation On Fetal Dose From Abdomen/Pelvis CT Scans
A Hardy1*, M Bostani1 , E Angel2 , C Cagnon1 , M McNitt-Gray1 , (1) UCLA, Los Angeles, CA, (2) Canon Medical Systems, Tustin, CA
TH-CD-207-12Patient Brain-Dose Estimation for Fluoroscopically-Guided Neuro-Interventional Procedures
Z Xiong*, C Guo, J Troville, S Rudin, D R Bednarek, The State University of New York at Buffalo, Buffalo, NY
TH-CD-DBRA-6Dosimetric Impact of Next-Generation ICRP Reference Computational Phantoms Based On Mesh Geometry
Y Yeom1*, C Lee1 , T Nguyen2 , C Choi2 , H Lee2 , H Han2 , B Shin2 , C Kim2 , (1) National Cancer Institute, Rockville, MD, USA (2) Hanyang University, Seoul, South Korea
TH-EF-202-1A Metropolis Monte Carlo Simulation Scheme for Ultra-Fast X-Ray Scattering Photon Calculation in Cone-Beam CT
Y Chen1*, Y Zhang1 ,Z Tian2 , S Jiang2 , L Zhou1 , X Jia2 , Y Xu1 , (1) Southern Medical University, Guangzhou, Guangdong, (2) UT Southwestern Medical Ctr at Dallas, Dallas, TX
TH-EF-KDBRA1-7Experimental Verification of 4D Monte Carlo Simulations in a Deforming Anatomy
S Gholampourkashi1*, J Cygler1,2 , B Lavigne2 , E Heath1 , (1) Carleton Univ, Ottawa, ON , (2) The Ottawa Hospital Cancer Centre, Ottawa, ON
TH-EF-KDBRA1-10Monte Carlo Simulation of the Dose From Radiosynoviorthesis Using Sn-117m, Er-169, and Re-186 Including Stochastic Macrophage Motion
A Gupta1*, N Stevenson2 , R Wendt3 , (1) Texas Tech University, Lubbock, TX, (2) Serene, LLC, The Woodlands, TX, (3) UT MD Anderson Cancer Center, Houston, TX
TU-AB-202-3Mammography and Breast Tomosynthesis Simulations for in Silico Clinical Trials and Deep Learning Classifier Training: Upgraded Models in the MC-GPU Code and Sensitivity Analysis of Input Parameters
A Badal*, D Sharma , C Graff , R Zeng , A Badano , Food & Drug Administration, Silver Spring, MD
TU-C1000-GePD-F7-2Development of Proton Minibeams as New Form of GRID Radiotherapy
S Charyyev*, C Wang , G Szalkowski , Georgia Institute of Technology, Atlanta, GA
TU-C1000-GePD-F7-5Clinical Impact of Approximations in Analytical Dose Computations in Lung Patients Receiving Proton Therapy
D Mirkovic1*, P Yepes2 , U Titt1 , C Peeler1 , Z Liao1 , R Mohan1 , (1) U.T M.D. Anderson Cancer Center, Houston, TX, (2) Rice University, Houston, TX
TU-C1030-GePD-F1-2Beam Quality of Flat Panel X-Ray Source Using Monte Carlo Simulation
Z Ding1*, S Yang2 , J huang1 , L Zhou1 , Y Xu1 , (1) Southern Medical University, Guangzhou, Guangdong, (2) The Fifth Affiliated Hospital, Sun Yat-sen University, Zhuhai, GuangDong
TU-C1030-GePD-F1-5Variations in Effective Doses Caused by Position of Cone Beam CT (CBCT) Scans
A Abuhaimed1*, C Martin2 , O Demirkaya3 , (1) King Abdulaziz City for Science and Technology, Riyadh, Saudi Arabia, (2) University of Glasgow, Glasgow, UK, (3) King Faisal Specialist Hospital and Research Center, Riyadh, Saudi Arabia.
TU-C1030-GePD-F3-1A Comparison Between Dosimetric Reporting Quantities for APBI Brachytherapy: MBDCA and Monte Carlo
G Fonseca1 , F Verhaegen1 , S Thrower2 , K Gifford2*, (1) Maastro Clinic, Maastricht, ,(2) UT MD Anderson Cancer Center, Houston, TX
TU-C1030-GePD-F3-4Influence of Convex Curvature for Improved Post-Surgical Dosimetry of a Directional Pd-103 Brachytherapy Implant
Reshma Munbodh1* and Mark J Rivard1, (1) Alpert Medical School of Brown University, Providence, RI
TU-C1030-GePD-F4-5Monte Carlo Based Secondary MU Checks
S Bhagroo1*, S French2 , J Mathews3 , D Nazareth4 , (1) ,Buffalo, NY, (2) Piedmont Healthcare, Fayetteville, GA, (3) Roswell Park Comprehensive Cancer Center, Buffalo, New York, (4) Roswell Park Cancer Institute, Buffalo, NY
TU-C1030-GePD-F6-4Simulated Calculations of the Biological Radiation Effects, TCP and NTCP Using Monte Carlo Simulation, and An Estimated Equivalent Uniform Dose
T Frometa-Castillo1*, (1) ,Oncology Hospital of Santiago de Cuba
TU-C930-GePD-F3-2Improving Calculation Accuracy of Dosimetric Quantities for KV and MV Photon Beams with EGSnrc
E Mainegra-Hing*, B Muir , National Research Council, Ottawa, ON
TU-C930-GePD-F9-1A Monte Carlo Study of the Impact of Electronic Noise On Low-Dose EPID Image Simulation
M Shi1 2*, M Myronakis2, Y Hu2, J Rottmann2, R Berbeco2, (1) University of Massachusetts Lowell, Lowell, MA, (2) Department of Radiation Oncology, Brigham and Women's Hospital, Dana Farber Cancer Institute, Harvard Medical School, Boston, MA
TU-C930-GePD-F9-2A Novel Method for Fast Image Simulation of Electronic Portal Imaging Device (EPID)
M Shi1 2*, M Myronakis2, Y Hu2, R Berbeco2, (1) University of Massachusetts Lowell, Lowell, MA, (2) Department of Radiation Oncology, Brigham and Women's Hospital, Dana Farber Cancer Institute, Harvard Medical School, Boston, MA
TU-D-202-4Dose Kernels in Water for More Than 700 Radioisotopes
S Graves1*, D Hyer1 , R Flynn1 , B Bednarz2 , (1) University Of Iowa, Iowa City, IA (2) University of Wisconsin, Madison, WI
TU-E115-GePD-F3-3SDD: A Standardized Data Format to Record DNA Damage
J Schuemann1*, A McNamara1 , J Warmenhoven2 , N Henthorn2 , M Merchent2 , K Kirkby2 , H Paganetti1 , S McMahon3 , (1) Massachusetts General Hospital & Harvard Medical School, Boston, MA, (2) The University of Manchester, Manchester, UK, (3) TQueen's University, Belfast, Bellfast,
TU-E115-GePD-F8-5Monte Carlo Based Reconstruction of Organ Dose in Patients Undergoing PICC and TIPS Fluoroscopically Guided Interventions
J Brown1*, D Kwak2 , J Duncan3 , W Bolch4 , (1) ,Gainesville, FL, (2) University of Central Florida College of Medicine, Orlando, Fl, (3) Mallinckrodt Institute of Radiology, Washington University School of Medici, Saint Louis, MO, (4) university Florida, Gainesville, FL
TU-GH-KDBRA1-4Optimization of a Microbeam Collimator for Use On the Small Animal Radiation Research Platform
N Esplen*, C Johnstone, L Chergui, M Bazalova-Carter, University of Victoria, Victoria, BC
TU-J430-CAMPUS-F3-1Analytical and Monte-Carlo Modeling of a Unique Beta-Source in Relation to Skin Surface Dosimetry
O Pen1*, J Bourland2 , P Antinozzi3 , (1) Wake Forest University, Virginia Tech-Wake Forest University School of Biomedical Engineering and Sciences, Winston-Salem, NC, (2) Wake Forest University, Wake Forest School of Medicine, Department of Radiation Oncology, Winston-Salem, NC, (3) Wake Forest University, Wake Forest School of Medicine, Department of Biochemistry, Winston-Salem, NC
TU-J430-CAMPUS-F3-4Monte Carlo Simulation Based Dose Calculation in Magnetic Field
M Qi1*, L Zhou1 , Y Li2 , T Song1 , (1) Southern Medical University, Guangzhou, Guangdong, (2) SUN YAT-SEN UNIVERSITY CANCER CENTER, Guangzhou, Guangdong,
TU-K-202-6Creation of a Set of Reference Data for Organ Doses Derived From Monte Carlo Simulations of CT Exams
A Hardy1*, M Bostani1 , E Angel2 , C Cagnon1 , M McNitt-Gray1 , (1) UCLA, Los Angeles, CA, (2) Canon Medical Systems, Tustin, CA
TU-K-DBRA-1Are Gold-Palladium Nanoparticles Vesicles Equivalent to Proton and 4He Ion in Cellular Dosimetry: A Monte-Carlo Study Based On Ex Vivo Imaging
Y Ma1,2*, M Laprise-Peletier2 , J Lagueux1,2 , M Cote1,2 , M Fortin2 , L Beaulieu1,2 , (1) CHU de Quebec, Quebec, QC, (2) Universite Laval, Ville De Quebec, QC
WE-AB-DBRA-4Dose Measurements and Monte Carlo Simulations of a Directional LDR Brachytherapy Source Array
M Aima*, L DeWerd, J Micka, C Hammer, J Hull, W Culberson, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, WI
WE-AB-DBRA-12Application of Civa-Sheet On Curved Surfaces
I Veltchev*, R Price , X Chen , K Howell , J Meyer , C Ma , Fox Chase Cancer Center, Philadelphia, Pennsylvania
WE-C1000-GePD-F8-5Monte Carlo Study of NanoDot OSLD for Surface Dose Measurements in Kilovoltage X-Ray Beams
F Araki1*, (1) Kumamoto University, Kumamoto,
WE-C1030-GePD-F1-1Comparing Lung and Breast Doses of Chest CT Exams From Organ-Based Tube Current Modulation (TCM) to Conventional Attenuation-Based TCM
A Hardy1*, R Layman2 , D Cody2 , M Bostani1 , C Cagnon1 , M McNitt-Gray1 , (1) UCLA, Los Angeles, CA, (2) UT MD Anderson Cancer Center, Houston, TX
WE-C1030-GePD-F1-5A Fast Monte Carlo Simulation Model for Wide-Beam CT Scanner
E Somasundaram1*, N Artz2 , S Brady1 , (1) Cincinnati Children's Hospital Medical Center, Cincinnati, Oh, (2) St Jude Children's Research Hospital, Memphis, Tn
WE-C1030-GePD-F3-1Clinical Impact of Upgrading Electron Calculation From Pencil Beam to Monte Carlo for Accelerated Partial Breast Irradiation (APBI)
S Zieminski*, Y Wang , Department of Radiation Oncology, Massachusetts General Hospital, Harvard Medical School, Boston, MA
WE-C1030-GePD-F3-2Dosimetric Differences Between Ray-Tracing and Monte Carlo Algorithms in Early Stage Lung Cancer Patients with Marginal Failures After SBRT
E Pryser*, KA Pearlstein, L Rankine, K Wang, B Mullins, J Holmes, LB Marks , AA Weiner, University of North Carolina, Chapel Hill, NC
WE-C1030-GePD-F3-4RECORDS: Improved Reporting of MontE CarlO RaDiation Transport Studies
I Sechopoulos1*, D Rogers2 , M Bazalova-Carter3 , W Bolch4 , E Heath5 , M McNitt-Gray6 , J Sempau7 , J Williamson8 , (1) Radboud University Medical Centre, Nijmegen, ,(2) Carleton Univ, Ottawa, ON, (3) university of Victoria, VCH040, Victoria, BC, (4) university Florida, Gainesville, FL, (5) Carleton Univ, Ottawa, ON, (6) David Geffen School of Medicine at UCLA, Los Angeles, CA, (7) Universitat Politecnica de Catalunya, Barcelona, ,(8) Washington University, Richmond, VA
WE-C1030-GePD-F9-3Development of Four-Dimensional Dose Calculation Method for Respiratory-Gated Radiotherapy by Using Real-Time Tumor Tracking System in Lung
R Onizuka1*, T Shiinoki2 , Y Yuasa1 , K Fujimoto1 , (1) Yamaguchi University Hospital, Ube, Yamaguchi, (2) Yamaguchi University, Ube, Yamaguchi,
WE-C930-GePD-F1-3Utilization of Voxel Phantom to Evaluate the Bone Marrow Dose in Pelvis CT Imaging of Children Using GATE Monte Carlo Code
S MehdizadehNaderi1,2*, R Safari1 , A Mehdizadeh1 , Z Moradi1 , S sina1,2 , (1) Nuclear engineering department, Shiraz University, Shiraz, Iran (2) Radiation Research Center, Shiraz University, Shiraz, Iran
WE-C930-GePD-F4-4Evaluation of Out-Of-Field Dose Calculation Accuracy of CyberKnife System in Heterogeneous Phantom
J Yoon*, S Sharma , Y Feng , East Carolina Univ, Greenville, NC
WE-C930-GePD-F8-3Entrance Skin Dose by DAP Meter Calibrated Based On 60Co Absorbed Dose to Water for Diagnostic X-Ray Beams
S Umeno*, F Araki , Kumamoto university, Kumamoto
WE-FG-KDBRA1-6Development of Quality Assurance Method for Dynamic Electron Arc Radiotherapy (DEAR)