SU-H400-GePD-F9-6 | Using the Maxwell Stress Tensor to Move Towards Predictive Magnetic Field Shaping in 3D A Shutler*, I Rutel , University of Oklahoma Health Science Center, Oklahoma City, OK |
SU-H430-GePD-F6-6 | Quantitative Comparison Between 3T and 7T MRI for Detection of Head and Neck Cancer for MRI-Based Treatment Planning M Lee1*, K Song1 , B Choe1 , T Suh1 , (1) Research Institute of Biomedical Engineering, The Catholic University of Korea, Seoul, Republic of Korea |
SU-H430-GePD-F8-6 | Use of Dielectric Pads to Improve Clinical 7T MRI Knee Image Uniformity A Fagan1*, K Amrami1 , M Frick1 , P Kollasch2 , J Felmlee1 , (1) Mayo Clinic, Rochester, MN, (2) Siemens Healthineers, Rochester, MN |
SU-K-KDBRA1-4 | Effect of a 1.4 T Magnetic Field On TLDs with a 6MV Medical Linear Accelerator W Culberson1*, W Culberson2 , C Hammer3 , R Kapsch4 , U Ankerhold5 , (1) university of Wisc Madison, Department of Medical Physics, School of Medicine and Public Health, Madison, WI, (2) university of Wisc Madison, Department of Medical Physics, School of Medicine and Public Health, Madison, WI, (3) University of Wisconsin Madison, Madison, Wisconsin, (4) Physikalisch Technische Bundesanstalt, Braunschweig, Germany (5) Physikalisch Technische Bundesanstalt, Braunschweig, Germany |
TU-K-KDBRC-2 | An Energy-Adaptive Finite Element Angular Discretization Towards a Fast Deterministic Dose Calculation in Magnetic Fields R Yang1,2, B Fallone1,2 , J St-Aubin3* , (1) Cross Cancer Institute, Edmonton, AB, (2) University of Alberta, Edmonton, AB, (3) University of Iowa, Iowa City, IA |
WE-AB-KDBRB1-2 | Application of Strong Magnetic Field to Manipulate Blood Rheology and to Lower Blood Pressure K Tawhid-Al-Islam1*, R Tao1 , M Autieri2 , X Xu1 , (1) Temple University, Philadelphia, PA, (2) Temple University - Lewis Katz School of Medicine, Philadelphia, PA |
WE-C1030-GePD-F7-2 | Effect of Magnetic Fields for the Response of Parallel-Plate Ionization Chambers in the Build-Up Region T Matsuoka*, F Araki , T Ohno , Kumamota UniversityKumamota |
WE-FG-KDBRB1-6 | BEST IN PHYSICS (JOINT IMAGING-THERAPY): On Axis and X-Band Linac Designs Enable Improved Passive Magnetic Shielding in MRI-Linac Systems B Whelan*, P Keall , University of Sydney, Camperdown, NSW |
WE-FG-KDBRB1-9 | Electron Return Effect Predictions From Treatment Planning System of An MR-Linac Underestimate the Observations Seen Using Scintillation and Cherenkov Optical Imaging J Andreozzi1*, P Bruza1 , J Cammin2 , D Gladstone3,1 , B Pogue1 , O Green2 , (1) Dartmouth College, Hanover, NH, (2) Washington University, School of Medicine, St. Louis, MO, (3) Dartmouth-Hitchcock Medical Center, Lebanon, NH, |