MENU

Click here to

×

Are you sure ?

Yes, do it No, cancel

DISCLAIMER:
Entry of taxonomy/keywords during proffered abstract submission was optional.
Not all abstracts will appear in search results.

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # | show all

Keywords: Immobilization
MO-E115-GePD-F4-1Development of a Rotational Set-Up Correction Device for Head Stereotactic Radiation Therapy
K Usui1*, N Hara2 , A Isobe2 , T Muroi2 , O Sajiki3 , K Ogawa4 , N Shikama1 , K Sasai1 , (1) Juntendo University, Bunkyo-ku, Tokyo, (2) Juntendo University Hospital, Bunkyo-ku, Tokyo, (3) Engineering System Co., Ltd., Matsumoto-shi, Nagano, (4) Hosei University, Koganei-shi, Tokyo
SU-H300-GePD-F4-6Improving Patient Positioning Reproducibility During Head and Neck Re-Simulation for Re-Treatment Using a Surface Mapping System
S Liu1*, P Dubrowski2 , Y Fu3 , D Yang4 , Y Yang5 , A Yu6 , (1) Stanford university Scool of Medicine, Stanford, CA, (2) Stanford University, Palo Alto, CA, (3) Washington University in Saint Louis, St. Louis, MO, (4) Washington University in St Louis, St Louis, MO, (5) Stanford University Cancer Center, Stanford, CA, (6) Stanford University Cancer Center, Stanford, CA
SU-I-GPD-E-4A Comparison of Two Kinds of Patient Marking Methods Used With Vacuum Cushion Immobilization in the Radiotherapy for Various Treatment Sites
J Pan*, D Yu , G Han , Q Song , C Ruan , J Fu , B Wu , G Ma , L Wang , Renmin Hospital of Wuhan University, Wuhan, Hubei
SU-I-GPD-J-15Patient Set Up Errors That OSMS and Small Field of View CBCT Cannot Catch with Varian Exact Couch Top
K Chu*, V Potari , M DeLuca , R Rostock , M Bailey , Western Connecticut Health Network, Danbury Hospital, Danbury, CT
SU-I-GPD-P-43Pre-Treatment Positional Shift Differences Between CBCT and Leksell Frame G MRI Fiducial Coordinates
J Stanford , J Treas*, A Youssef , J Sheehan , Holy Spirit Cancer Center - A Geisinger Affiliate, Mechanicsburg, PA
SU-I-GPD-T-63Multi Pillow Device for Automated Patient Setup in Radiotherapy
P Haering*, M Splinter , C Lang , W Johnen , A Runz , DKFZ, Heidelberg, BW
SU-I-GPD-T-66Evaluation of Head and Neck Immobilization Device with and Without Shoulder Suppressor
P Rassiah-Szegedi*, M Szegedi , V Sarkar , S Lloyd , C Haacke , F Su , Y Huang , L Huang , Y Hitchcock , B Salter , University Utah, Salt Lake City, UT
SU-I-GPD-T-157Pre-Treatment Table Coordinate Prediction for Improving Patient Safety in Radiation Therapy
N Astorga*, D Saenz , N Kirby , K Rasmussen , S Stathakis , N Papanikolaou , Ut Health San Antonio, San Antonio, TX
SU-I-GPD-T-406Dosimetric Impact of BodyFix Immobilization System for Stereotactic Body Radiation Therapy
S Srivastava1,2*, S Jani1,2 , D Pinnaduwage1,2 , X Yan1,2 , P Metuge1,2 , D Castaneda2 , S Patel2 , N Thawani2 , S Mutyala2 , I Das3 , S Sorensen1,2 , (1) Barrow Neurological Institute, Phoenix, AZ, (2) University of Arizona Cancer Center \ Dignity Health, St. Joseph's Hospital, Phoenix, AZ, (3) NYU Langone Medical Center, New York, NY,
TU-C1000-GePD-F2-5Development of 3D Printed Immobilization for the MR-Linac: Toward High Precision Brain Treatments
C Glide-Hurst*, E Myers , D Du , J Kim , N Wen , B Movsas , S Siddiqui , T Walbert , S Kalkanis , I Chetty , Henry Ford Cancer Institute, Detroit, MI