DISCLAIMER:
Entry of taxonomy/keywords during proffered abstract submission was optional.
Not all abstracts will appear in search results.
MO-E115-GePD-F6-1 | A Simple Tool to Assess the Gamma Knife Icon IFMM System J Napoli1*, L Napoli2 , j barbiere3 , A Ndlovu4 , (1) Hackensack university Medical Center, Hackensack, NJ, (2) RCA Research Laboratory (Ret.), Long Beach Township, NJ, (3) ,,,(4) Hackensack university Medical Center, Hackensack, NJ |
SU-E-209-5 | Efficacy and Utilization Rate of Shot Within Shot Optimization for Gamma Knife Radiosurgery Planning P Johnson*, M Monterroso , F Yang , University of Miami, Miami, FL |
SU-H400-GePD-F4-2 | Failure Modes and Effects Analysis (FMEA) for Mask-Based Radiosurgery On Gamma Knife Icon Andy Y. Xu*, Tony J.C. Wang, Mike Sisti, C.S. Wuu , Columbia University Medical Center, New York, New York |
SU-I-GPD-J-56 | A Radiomic Assessment of the Progression of Acoustic Neuroma After Gamma Knife Stereotactic Radiosurgery G Narayanasamy1*, G Zhang2 , E Siegel3 , G Campbell 4 , E Moros2 , E Galhardo1 , X Zhang1 , S Morrill1 , J Penagaricano1 , (1) Department of Radiation Oncology, University of Arkansas for Medical Sciences, Little Rock, AR, (2) H. Lee Moffitt Cancer Center, Tampa, FL, (3) Department of Biostatistics, University of Arkansas for Medical Sciences, Little Rock, AR, (4) College of Medicine, University of Arkansas for Medical Sciences, Little Rock, AR |
SU-I-GPD-P-2 | Evaluation of the Leksell Gamma Knife Perfexion Clinical Workload at M.D. Anderson Cancer Center M Chetvertkov*, D Luo , T Briere , M.D. Anderson Caner Center, Houston, TX |
SU-I-GPD-P-43 | Pre-Treatment Positional Shift Differences Between CBCT and Leksell Frame G MRI Fiducial Coordinates J Stanford , J Treas*, A Youssef , J Sheehan , Holy Spirit Cancer Center - A Geisinger Affiliate, Mechanicsburg, PA |
SU-I-GPD-T-389 | Optimized Dose Delivery for a New Generation Rotating Gamma System J Xu*, A Eldib , L Jin , C Ma , Fox Chase Cancer Center, Philadelphia, Pennsylvania |
SU-I-GPD-T-402 | Normal Brain Dose Sparing with Gamma Knife and Linac-Based Stereotactic Radiotherapy for Multiple Brain Metastases J Carter*, I Vergalasova , X Wang , K Grantham , M Reviello , Y Zhang , J Weiner , N Yue , K Nie , Rutgers University, New Brunswick, NJ |
SU-I-GPD-T-410 | Simple Prediction of Gamma Knife Treatment Time for Single and Multiple Brain Metastases J Vergara1,2, A Riegel1,2 , (1) Northwell Health, Lake Success, NY, (2) Hofstra University, Hempstead, NY |
SU-I-GPD-T-417 | Variations in Gamma Knife Dose Calculations Based On Skull Measurement Variability James M Brindle1* and Mark J Rivard1, (1) Warren Alpert School of Medicine at Brown University, Providence, RI |
SU-I-GPD-T-420 | Radiochromic Film-Based Validation of the Leksell GammaPlan Convolution Algorithm with Heterogeneity J Rakowski1 , A Santiago2*, (1) Karmanos Cancer Institute, Detroit, MI, (2) Wayne State University, Detroit, MI |
SU-I-GPD-T-428 | Comparison of the Traditional Indicator Box Markers and New CBCT Localization for the Frame Treatments On the Gamma Knife Icon G Neyman1*, (1) The Cleveland Clinic Foundation, Beachwood, OH |
SU-I-GPD-T-429 | Impact of Head Pin Torque On Gamma Knife Frame Distortion D Wieczorek*, V Mishra , R Kotecha , M Hall , T Poozhikala , A Gutierrez , Miami Cancer Institute, Miami, FL |
TU-I345-GePD-F5-4 | Localization Methods of the Gamma Knife Icon and Effects of Image Scan Parameters W Duggar*, C Yang , University of Mississippi Med. Center, Jackson, MS |
TU-I345-GePD-F5-5 | Quantitative Assessment of a New Onboard Imaging System for Leksell Gamma Knife Icon J Stanford*, J Treas , A Youssef , J Sheehan , Holy Spirit Cancer Center- A Geisinger Affiliate, Mechanicsburg, PA |
WE-FG-KDBRA1-3 | Adapting 3D Printer Technology for QA of Gammaknife Icon High Definition Motion Management System K Grantham*, N Yue , K Nie , Rutgers University, New Brunswick, NJ |