Keywords: Flattening Filters
MO-C930-GePD-F7-4Flattened Photon Beams, An Obsolete Feature in Modern LINACS
J Wan*, J Bogue , D Shvydka , S Tanny , E Parsai , University of Toledo Medical Center, Toledo, OH
SU-H400-GePD-F7-13D In-Vivo Portal Dosimetry for Hypo-Fractionated Radiotherapy with Flattening-Filter-Free Beams: First Results
A Taborda1 , J Stroom1*, S Nijsten2 , C Greco1 , (1) Champalimaud Foundation, Department of Radiotherapy, Lisbon, Portugal (2) University Hospital of Maastricht, Department of Radiation Oncology (MAASTRO), Maastricht, The Netherlands
SU-I-GPD-T-231Photon Energy Spectral Analysis in the Mucosal Dose with and Without the Flattening Filter: A Monte Carlo Study
J Chow1*, A Owrangi2 , (1) Princess Margaret Cancer Centre, Toronto, ON, (2) UT Southwestern Medical Center, Dallas, TX
SU-I-GPD-T-233Skin Dose Enhancement for Patients Using Skin-Care Cream During Radiotherapy: A Monte Carlo Study Using the Flattened and Unflattened Photon Beam
M Sharma1 , K Tse2 , L Morley2 , A Cashell2 , A Sperduti2 , M McQuestion2 , J Chow2*, (1) Ryerson University, Toronto, ON, (2) Princess Margaret Cancer Centre, Toronto, ON
SU-I-GPD-T-300Study Of Dosimetric Properties Of Flattened And Un-Flattened Mega Voltage X-Ray Beam On High Z Implant Materials
Tamilarasan Rajamanickam1*, Sivakumar Muthu.1 , Perumal Murugan1 , Muddappa Pathikonda1 , Senthilnathan K.2 , Arunai Nambi Raj N.2 , Ramesh Babu P.2 , (1) Sri Shankara Cancer Hospital & Research Centre, Bangalore, Karnataka, (2) Vellore Institute of Technology, Vellore, Tamilnadu
SU-I-GPD-T-305Comparisonof Head Scatter Factor by Different Ion-Chambers in Flattened and Unflattened Beams
T Miwa1,2*, M Oita2 , H Aoyama3 , (1) Department of Radiological Technology, Seitetsu Hirohata Hospital,Japan, (2) Graduate school of Health Sciences, Okayama University, Japan, (3) Department of Radiological Technology,Okayama University Hospital, Japan
SU-I-GPD-T-314Dose Delivery Accuracy of Flattening Filter Free Beams at Low Monitor Unit Settings
H GODSON1*, R MANICKAM2 , S Kumar1 , R PONMALAR1 , S GEORGE1 , P Ravindran1 , R SINGH1 , (1) CHRISTIAN MEDICAL COLLEGE, Vellore, TAMIL NADU, (2) KIDWAI CANCER CENTER, Bangalore, KARNATAKA
SU-I-GPD-T-386A RayStation Experience On Implementing Flattening Filter-Free (FFF) IMRT and VMAT with Multicriteria Optimization (MCO) for Lung SBRT
H Prichard*, C Cotter , F K Keane , Y Wang , Department of Radiation Oncology, Massachusetts General Hospital, Harvard Medical School, Boston, MA
SU-I-GPD-T-403Dose Rate Dosimetric Effects During the 6 MV Flattening Filter Free RapidArc-Based Stereotactic Body Radiation Therapy On Lung
N Dumitru1*, M Pudasaini1 , S Pella1,2 , T Leventouri1 , (1) Florida Atlantic University, Boca Raton, Florida, (2) 21st Century Oncology, Boca Raton, FL