MENU

Click here to

×

Are you sure ?

Yes, do it No, cancel

DISCLAIMER:
Entry of taxonomy/keywords during proffered abstract submission was optional.
Not all abstracts will appear in search results.

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # | show all

Keywords: Eye Plaques
SU-I-GPD-T-5Use of Conventional Ionization Chambers with Ru-106 Plaques to Transfer Convex Extrapolation Chamber Result for Surface Dose Rate to Clinics
J Hansen*, W Culberson , L DeWerd , university of Wisconsin-Madison, Madison, WI
SU-I-GPD-T-25Optic Disc and Macula Dose Estimation Without Dose Calculations in Ocular Brachytherapy Using 125I Standard COMS Plaques
S Lin*, Y Lee, Y Kim, The University of Arizona, Tucson, AZ
SU-I-GPD-T-26Optic Disc Dose Reduction in Ocular Brachytherapy Using 125I Notched COMS Plaques
Y Lee1*, S Lin1 , Y Xu1 , Y Kim1 , (1) University of Arizona, Tucson, AZ
SU-I-GPD-T-27Comparison of Optic Disc Dose Reduction Between 125I and 103Pd Notched COMS Plaques in Ocular Brachytherapy
Y Lee1*, S Lin1 , Y Kim1 , (1) University of Arizona, Tucson, AZ
SU-I-GPD-T-39The Impact of Point and Line Source Models On Dose Calculation for I-125 Brachytherapy Using Eye Physics Eye Plaques
D Olek1*, K Homann2 , S Scarboro3 , (1) ,,,(2) Methodist Hospital, Houston, TX, (3) University of Virginia, Charlottesville, VA
SU-I-GPD-T-42Dosimetric Impact of Different Radionuclides On Eye Plaque Brachytherapy
P Aryal1*, M Rivard2 , (1) University of Maryland School of Medicine, Baltimore, MD, (2) Department of Radiation Oncology, Alpert Medical School of Brown University, Providence, RI
SU-L-KDBRA2-3Inter-Laboratory Comparison for Surface Dose Rate From a Ru-106 Episcleral Plaque Measured with a Convex Windowless Extrapolation Chamber, EBT3 Film, a Scintillation Detector, and Alanine Pellets
J Hansen*, W Culberson , L DeWerd , university of Wisconsin-Madison, Madison, WI
TU-C1030-GePD-F3-2A Retrospective Comparison of TG-43 Calculated and Heterogeneity-Corrected Dose Distributions for 125I COMS Eye Plaques
S Simiele*, A Choi , H Cho , C Lee , University of Michigan, Ann Arbor, MI
TU-E115-GePD-F6-3Development and Application of a High Precision Optical Guidance System for Customizable I-125 Eye Plaque Production
K Nealon*, A Ayan , N Gupta , J Woollard , Ohio State Univ, Columbus, OH
WE-AB-DBRA-8Microresolution Dosimetry System for Patient Specific Quality Assurance of Ocular Melanoma Eye Plaque Based Treatments
S Pokhrel1*, A Wiles1 , T Knewtson1 ,Y Feng 1,2, M Ballo1,2 , E W Izaguirre1,2 , (1) university Tennessee Health Science Center,Methodist university Hospital, Memphis, TN., (2)West Cancer Center, Germantown, TN.