MO-E115-GePD-F8-2 | Experience with the Set-Up of a 7T Clinical MRI Scanner A Fagan1*, R Watson1 , S Carlson1 , K Amrami1 , K Welker1 , J Felmlee1 , (1) Mayo Clinic, Rochester, MN |
MO-I345-GePD-F8-2 | Comparison of B1 Field-Calibrated Specific Absorption Rate Estimation Between a Whole-Body and a Compact 3T MR Scanner Y Shu , N Huber , S Tao , M In , J Trzasko , J Huston , M Bernstein*, Mayo Clinic, Rochester, MN |
SU-H400-GePD-F7-3 | Portal Dosimetry Based Patient-Specific QA of a New Ring-Gantry Linac Yielded Similar Passing Rate Compared to a Portable Ion Chamber Array Based QA P Teo*, F Li , K Fallon , P Kosterin , Z Shen , S Jang , R Lalonde , G Bednarz , M Huq , University of Pittsburgh Cancer Institute, Pittsburgh, PA |
SU-I-GPD-P-51 | Development of Measurement Technique to Determine Beam Quality Conversion Factor for High-Energy Electron Beams K Hirayama1,2*, T Saitou1,2, M Shimizu2, Y Morishita2, S Seno3, N Kinoshita4, H Oguchi3, M Hoshina1 (1) Komazawa Univ., Setagaya-ku, Tokyo (2) National Metrology INstitute of Japan, AIST, Tsukuba-shi, Ibaraki (3) Nagoya Univ., Nagoya-shi, Aichi (4) University of Fukui hospital, Yoshida-gun, Fukui |
SU-I-GPD-T-110 | Preliminary Research On Calibration of 2D Detector of Dose Response with Co-60 Applied to Proton Beams Y.C. Lin1*, S.Y. Cai2 , M.C. Yuan3 , Y.W. Tsai4 , F.X. Chang5 , T.S. Duh6 , C.C. Chiang Hsieh7 , A.E. Chen8 , (1) Health Physics Division, Institute of Nuclear Energy Research, Taoyuan city, Taiwan(R.O.C.), (2) National Central University, Taoyuan City, Taiwan(R.O.C.), (3) Institute of Nuclear Energy Research, Taoyuan City, Taiwan(R.O.C.), (4) National Central University, Taoyuan City, Taiwan(R.O.C.), (5) Academia Sinica, Taipei, Taiwan(R.O.C.), (6) Institute of Nuclear Energy Research, Taoyuan City, Taiwan(R.O.C.), (7) Taiwan Power Company, Taipei, Taiwan(R.O.C.), (8) National Central University, Taoyuan City, Taiwan(R.O.C.) |
SU-I-GPD-T-330 | A Simplified Commissioning Procedure for the Halcyon Linear Accelerator S AM Lloyd*, T Lim , X Fave , E Flores-Martinez , V Moiseenko , K L Moore , T F Atwood , UC San Diego, La Jolla, CA |
SU-L-KDBRA1-7 | Risk Assessment for the Acceptance and Commissioning Process of a New Ring-Gantry Linear Accelerator P Teo*, P Kosterin , M Hwang , S Jang , W Shields , R Lalonde , M Huq , University of Pittsburgh Cancer Institute, Pittsburgh, PA |
SU-L-KDBRA2-5 | Robust Individual TLD Tracking Using Optical Finger Printing Technology D Shang*, W Gu , A Landers , K Woods , R Neph , S Tenn , K Sheng , UCLA School of Medicine, Los Angeles, CA |
TU-K-202-8 | The Quantification and Comparison of the Inherent Radiopacity of Glass Microspheres Used in Transarterial Radioembolization C Henry1*, G Mawko1,2,3,6, E Tonkopi1,2,3, J Frampton4, R Abraham2,7, D Boyd5,7, S Kehoe5,7, A Syme6 (1) Department of Physics and Atmospheric Science, Dalhousie University, Halifax, Nova Scotia, Canada (2) Department of Diagnostic Imaging, Dalhousie University, Halifax, Nova Scotia, Canada (3) Department of Medical Physics, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada (4) Department of Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada (5) Department of Applied Oral Sciences, Dalhousie University, Halifax, Nova Scotia, Canada (6) Department of Radiation Oncology, Dalhousie University, Halifax, Nova Scotia, Canada (7) ABK Biomedical Inc., Halifax, Nova Scotia, Canada |
WE-C930-GePD-F8-3 | Entrance Skin Dose by DAP Meter Calibrated Based On 60Co Absorbed Dose to Water for Diagnostic X-Ray Beams S Umeno*, F Araki , Kumamoto university, Kumamoto |