DISCLAIMER:
Entry of taxonomy/keywords during proffered abstract submission was optional.
Not all abstracts will appear in search results.
MO-C930-GePD-F4-1 | An Image Processing Technique for Identification of Interstitial Catheters in High- and Low-Field MR-Guided HDR Brachytherapy K Singhrao*, S Park , T Wong , Y Gao , M Guo , J Fu , P Hu , Y Yang , A Chang , J Lewis , UCLA School of Medicine, Los Angeles, CA |
MO-C930-GePD-F4-4 | Prediction of Development of Rectovaginal Fistula Following Interstitial Brachytherapy for Advanced Cervix Cancer Using Machine Learning Z Tian*, A Yen , Z Zhou , C Shen , K Albuquerque , B Hrycushko , UT Southwestern Medical Center, Dallas, TX |
MO-C930-GePD-F4-6 | Validation of a Commercial Oncentra Brachy TPS Using the Advanced Collapse Cone Engine (ACE) Algorithm for Direction Modulated Brachytherapy (DMBT) Tandem Applicator H Safigholi1*, Y Niatsetski2, W Song3, (1) Department of Electrical Engineering, Islamic Azad University, Shiraz Branch, Iran, (2) Virginia Commonwealth University, Richmond, VA,USA (3) Elekta Brachytherapy, Veenendaal,Netherlands |
MO-I345-GePD-F8-6 | The Design And Development Of A Novel Contrast Detail Phantom For The Objective Assessment Of Ultrasound Systems Used In Image Guided Prostate Brachytherapy A Doyle1*, J Browne2 , D King3 , F Sullivan4 , D Cody5 , (1) ,,,(2) Dublin Institute of Technology, Dublin 8, Dublin, (3) Blackrock Clinic, County Dublin, Dublin, (4) Prostate Cancer Institute, National University of Ireland, Galway, Ireland, Galway, ,(5) Dublin Institute of Technology, Dublin, Dublin 8 |
MO-K-DBRA-5 | Incorporating a Novel Radiomics Framework for Biologically Optimised Prostate RadioTherapy (BiRT) A Haworth1*, Y Sun2 , M Ebert3 , H Reynolds4 , J Betts5 , D Wraith6 , C Mitchell7 , D Murphy8 , S Williams9 , (1) University of Sydney, Sydney, New South Wales, (2) University of Sydney, Sydney, New South Wales, (3) The University of Western Australia, Nedlands, ,(4) Peter MacCallum Cancer Centre, Melbourne, Victoria, (5) Monash University, Clayton, Vic, (6) Queensland University of Technology, Kelvin Grove, Qld, (7) Peter MacCallum Cancer Centre, Parkville, Vic, (8) Peter MacCallum Cancer Centre, Parkville, Vic, (9) Peter MacCallum Cancer Centre, Melbourne, Victoria |
SU-F-DBRA-2 | Automatic Tandem and Ring Digitization for MRI-Guided Cervical Cancer Brachytherapy WT Hrinivich*, M Morcos, J Lee, A Viswanathan, T McNutt, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, MD |
SU-F-KDBRB1-1 | An Imaging-Informed Model for Convection Enhanced Radio-Liposome Delivery R Woodall1*, D Hormuth1 , X Feng1 , W Phillips2 , A Bao3 , A Brenner2 , T Yankeelov1 , (1) The University of Texas at Austin, Austin, TX, (2) The University Of Texas San Antonio, San Antonio, Texas, (3) University Hospitals Cleveland Medical Center, Cleveland, OH |
SU-H300-GePD-F4-3 | Keyway Selection Optimization for Multi-Helix Rotating Shield Brachytherapy (H-RSBT) A D Le12*, J Yi2 , Y Kim1 , R Flynn1 , W Xu2 , X Wu12 , (1) Department of Radiation Oncology, University of Iowa, Iowa City, IA - Iowa, (2)Department of Electrical and Computer Engineering, University of Iowa, Iowa City, IA - Iowa, |
SU-H300-GePD-F4-4 | Movement of Cs-131 Seeds in Absorbable Mesh in the Treatment of Head and Neck Cancer Recurrence G Warrell1*, M Yao1 , C Zender1 , Z Xu1 , J Muenkel1 , D Albani1 , T Podder1,2 , (1) University Hospitals Cleveland Medical Center, Cleveland, Ohio, (2) Case Western Reserve University, Cleveland, Ohio |
SU-H330-GePD-F7-1 | A Novel Electromagnetic-Tracked Scintillation Dosimeter for Accurate in Vivo Dosimetry in HDR Brachytherapy D Tho*, L Beaulieu , Centre Hospitalier university de Quebec, Quebec, QC |
SU-H330-GePD-F7-2 | Dosimetry of Beta-Emitting Brachytherapy Sources for Age-Related Macular Degeneration Mark J Rivard1*, Kyle T Mohney2 , Toby S Welles2 , Paul T Finger2, (1) Rhode Island Hospital / Warren Alpert Medical, Providence, RI, (2) LV Liberty Vision Corp., Portsmouth, NH |
SU-H330-GePD-F7-3 | Dynamic-Direction Modulated Brachytherapy (d-Dmbt) For Cervical Cancer Using HDR Yb-169 Source H Safigholi1*, W Song2, (1) Department of Electrical Engineering, Islamic Azad University, Shiraz Branch, Iran (2) Virginia Commonwealth University, Richmond, VA, USA |
SU-H330-GePD-F7-4 | How Normalization Method Affects Target Coverage for Leipzig-Style Applicators in HDR Skin Brachytherapy D Christ*, K Noa , M Carlson , N Gupta , Ohio State Univ, Columbus, OH |
SU-H330-GePD-F7-6 | A Plan Quality Assurance Method for HDR Breast Brachytherapy with Multi-Lumen Balloon Applicator M Napiwocki1 , Y Le2*, (1) Purdue University, West Lafayette, Indiana, (2) Indiana University- School of Medicine, Indianapolis, IN |
SU-I-GPD-J-37 | Biomechanical Modeling of Compressed Breast Tissue F Liu*, E Klein , Warren Alpert School of Medicine at Brown University, Providence, RI |
SU-I-GPD-P-23 | Patient Specific 3D Template Printing for Temporary Brachytherapy Treatments D Bragilovski1 , I Tzadok2 , R Ben-Hur1 , S Alani2 , J Kindler1 , A Popovtzer1 , G Cohen3 , S Koren2*, (1) Davidoff Cancer Center - Rabin Medical Center, Petah Tikva, ISRAEL ,(2) Ziv Medical Center, Safed, ISRAEL, (3) Memorial Sloan-Kettering Cancer Center, NY, NY |
SU-I-GPD-P-26 | Is It Better to Treat Lip Cancer From Inside-Out Or Outside-in for High-Dose-Rate Skin Brachytherapy? S Park1*, P Venkat1 , A Chang1 , J Jayanetti2 , D Demanes1 , (1) UCLA Department of Radiation Oncology, Los Angeles, CA, (2) UCLA , School of Dentistry, Los Angeles, CA |
SU-I-GPD-T-2 | Surface Applicator-Based Electronic Brachytherapy Commissioning with a Focus On Individual Source Derived Performance Expectations T Denton1,2, (1) Associates in Medical Physics, LLC, Greenbelt, MD (2) The Norton Cancer Institute Radiation Center, Louisville, KY |
SU-I-GPD-T-3 | A Verification of High-Dose-Rate Brachytherapy Dose Distributions for Prostate Cancer with a VIPET Polymer Gel Dosimeter K Eguchi1*, Y Watanabe2 , S Mizukami2 , T Maeyama3 , S Hayashi4 , T Gomi2 , (1) Kitasato University Graduate School of Medical Sciences, Sagamihara, Kanagawa, Japan, (2) School of Allied Health Sciences, Kitasato University, Sagamihara, Kanagawa, Japan, (3) School of Science, Kitasato University, Sagamihara, Kanagawa, Japan, (4) Faculty of Health Sciences, Hiroshima International University, Higashihiroshima, Hiroshima, Japan, |
SU-I-GPD-T-4 | Quantitative HDR Afterloader Source Position QA Using Two MicroDiamond Detectors T Harris1*, R Cormack2 , I Buzurovic3 , D O'Farrell4 , J Bredfeldt5 , M Bhagwat6 , (1) Brigham & Women's Hospital, Boston, MA, (2) Brigham and Women's Hospital, Boston, MA, (3) Brigham & Women's Hospital, Harvard Medical School, Boston, MA, (4) Dana Farber Cancer Institute, Boston, MA, (5) Brigham and Women's Hospital, Boston, MA, (6) Dana Farber/Brigham and Women's Hospital, Boston, MA |
SU-I-GPD-T-7 | Clinical HDR Brachytherapy Plan Dose Verification for Multiple Channel Cylinders J Muenkel*, T Podder, University Hospitals, Cleveland Medical Center, Cleveland, OH |
SU-I-GPD-T-8 | Design of a Real Time Online Tracking Solution for HDR Inventory N Astorga*, K Rasmussen , N Kirby , J Roring , S Stathakis , D Saenz , R Crownover , N Papanikolaou , R George , Ut Health San Antonio, San Antonio, TX |
SU-I-GPD-T-12 | Inverse Planning the Geometry of Intracavitary Applicators Used in GYN Brachytherapy M Platt*, M Lamba , W Kassing, D Ionascu, University of Cincinnati, Cincinnati, OH |
SU-I-GPD-T-13 | Benefits of MR Imaging On Volume Segmentation for HDR Brachytherapy E Schnell*, S Thompson , S Ahmad , T De La Fuente Herman , University of Oklahoma Health Science Center, Oklahoma City, OK |
SU-I-GPD-T-14 | Assessing the Improvement in Brachytherapy with the Usage of Multichannel Applicators E Schnell*, S Thompson , S Ahmad , T De La Fuente Herman , University of Oklahoma Health Science Center, Oklahoma City, OK |
SU-I-GPD-T-19 | Dosimetric Comparison of Venezia Advanced Gynecologic Applicator and Split-Ring and Tandem Applicator in HDR Intracavitary/interstitial Brachytherapy Z Xu1*, B Traughber1,2 , G Warrell1 , J Muenkel1 , V Colussi1,2 , R Ellis1,2 , T Podder1,2 , (1) University Hospitals Cleveland Medical Center, Cleveland, Ohio, (2) Case Western Reserve University, School of Medicine, Cleveland, Ohio |
SU-I-GPD-T-22 | Comparison of Vertical and Horizontal Oriented Source Leipzig-Style Skin Brachytherapy Applicators M Carlson , N Gupta , K Noa , D Christ*, Ohio State Univ, Columbus, OH |
SU-I-GPD-T-25 | Optic Disc and Macula Dose Estimation Without Dose Calculations in Ocular Brachytherapy Using 125I Standard COMS Plaques S Lin*, Y Lee, Y Kim, The University of Arizona, Tucson, AZ |
SU-I-GPD-T-26 | Optic Disc Dose Reduction in Ocular Brachytherapy Using 125I Notched COMS Plaques Y Lee1*, S Lin1 , Y Xu1 , Y Kim1 , (1) University of Arizona, Tucson, AZ |
SU-I-GPD-T-27 | Comparison of Optic Disc Dose Reduction Between 125I and 103Pd Notched COMS Plaques in Ocular Brachytherapy Y Lee1*, S Lin1 , Y Kim1 , (1) University of Arizona, Tucson, AZ |
SU-I-GPD-T-28 | Dose Error in Using Point Source Approximation for Permanent Brain Seed Implants S Sorensen*, D Pinnaduwage , E Youssef , S Srivastava , X Yan , S Jani , D Brachman , Barrow Neurological Institute, Phoenix, AZ |
SU-I-GPD-T-29 | Dosimetric Impact of Source Migration and Decay Based On Radioisotope Type in Collagen Carrier Brain Brachytherapy Implants D Pinnaduwage*, S Sorensen , E Youssef , S Srivastava , X Yan , S Jani , D Brachman , Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, AZ |
SU-I-GPD-T-31 | Evaluation of Inter-Seed Attenuation in LDR Brachytherapy Using Artificial Neural Network (ANN) K Bayati1 , S sina1,2 , R Faghihi1,2*, (1) Nuclear engineering department, Shiraz University, Shiraz, Iran (2) Radiation Research Center, Shiraz University, Shiraz Iran, |
SU-I-GPD-T-32 | Assessment of the Anatomical Position of Point B and the Relationship Between Point B Dose and the Dose Delivered to Pelvic Lymph Nodes in CT-Based HDR Brachytherapy for Uterine Cervical Cancer H Matsukawa1*, T Sasaki1 , R Hirayama2 , T Hirose2 , J Fukunaga2 , (1) Kyushu University, Fukuoka-shi, Fukuoka-ken, Japan, (2) Kyushu University Hospital, Fukuoka-shi, Fukuoka-ken, Japan |
SU-I-GPD-T-33 | A Nomogram to Determine Required Seed Activity in Planar Cesium-131 Permanent Seed Implants E Hubley*, M Trager , L Doyle , Thomas Jefferson University Hospital, Philadelphia, PA |
SU-I-GPD-T-34 | Evaluation of the Applicator Library Modelling Based Planning for Tandem and Ring HDR Treatment of Cervical Cancer A Smith*, S Zhou , A Wahl , D Zheng , S Wang , Y Lei , Q Fan , University of Nebraska Medical Center, Omaha, NE |
SU-I-GPD-T-35 | Correlation of Tc-99m MAA and Y-90 SPECT/CT Activity Distributions Using SUV Thresholding M Studenski*, R Llorente , L Portelance , University of Miami, Miami, FL |
SU-I-GPD-T-36 | Obtaining the Phase Space of An Electronic Brachytherpy Equipment for Surfaces Treatments Through Monte Carlo Simulations C Valdes*1,2, Yury Niatsetski3, J Perez-Calatayud1,4, J Vijande1, F Ballester1, (1) University of Valencia, Valencia, Spain, (2) Centro Oncologico de Antofagasta, Antofagasta, Chile, (3) Elekta Brachyhtherapy, Veenendal, The Neetherlands, (4) La Fe Hospital, Valencia, Spain |
SU-I-GPD-T-37 | Urethral Dosimetry in Image Guided Tandem and Ovoid High-Dose-Rate Brachytherapy J Hanna*, R Yaparpalvi , K Mehta MD , W Tome PhD, Montefiore Medical Center, Bronx, NY |
SU-I-GPD-T-38 | Dosimetric Evaluations of the Bladder and Rectum in Brachytherapy Treatments Using Multi-Lumen Cylinders N Dumitru1*, M Shojaei1 , S Pella1,2 , T Leventouri1 , (1) Florida Atlantic University, Boca Raton, Florida, (2) 21st Century Oncology, Boca Raton, FL |
SU-I-GPD-T-39 | The Impact of Point and Line Source Models On Dose Calculation for I-125 Brachytherapy Using Eye Physics Eye Plaques D Olek1*, K Homann2 , S Scarboro3 , (1) ,,,(2) Methodist Hospital, Houston, TX, (3) University of Virginia, Charlottesville, VA |
SU-I-GPD-T-40 | Experimental Investigation of TG-43 and ACE On the Effects of High-Z Materials in HDR Freiburg Flap Treatments C Page*, M Baca , T Sokolowski , S Heitman , A Sadeghi , Banner MD Anderson Cancer Center, Gilbert, AZ |
SU-I-GPD-T-42 | Dosimetric Impact of Different Radionuclides On Eye Plaque Brachytherapy P Aryal1*, M Rivard2 , (1) University of Maryland School of Medicine, Baltimore, MD, (2) Department of Radiation Oncology, Alpert Medical School of Brown University, Providence, RI |
SU-I-GPD-T-43 | Comparing Cervical Cancer Treatment Planning with Yb169, Ir192, and Co60 HDR Brachytherapy Sources H Safigholi1*, W Song2 , (1) Department of Electrical Engineering, Islamic Azad University, Shiraz Branch, Iran (2) Department of Radiation and Oncology, Virginia Commonwealth University, Richmond, VA, USA |
SU-I-GPD-T-44 | Prostate LDR Edema Effects On D90 for Cs-131 Implants W Zimmerman*, W St.Clair , D Pokhrel , W Luo , J Molloy , D Cheek , University of Kentucky, Lexington, KY |
SU-I-GPD-T-45 | A Detailed Theoretical Gold Nanoparticle Dose Enhancement Study for Low Gold Concentrations in Tumors Treated with External Beam Radiotherapy and HDR Ir-192 Brachytherapy Using MCNP6 T Gray1*, N Bassiri2 , N Kirby3 , K Mayer4 , (1)University of Texas at San Antonio, San Antonio, TX (2) UT Health San Antonio, San Antonio, TX, (3) UT Health San Antonio, San Antonio, TX, (4) University of Texas at San Antonio, San Antonio, Texas |
SU-I-GPD-T-46 | Evaluation of the First Clinical System Fully Integrating EM Tracking Technology for Intra-Op US Guided Prostate HDR Procedure M Lavallee1*, L Beaulieu2 , (1) CHU de Quebec, Quebec, Quebec, (2) Centre Hospitalier university de Quebec, Quebec, QC |
SU-I-GPD-T-70 | Study of the TraceIT as a Hydrogel Spacer for Rectal Sparing in Recurrent Endometrial Cancer Y Liao*, A Templeton , A Osmanuddin , Z Grelewicz , J Turian , C Hogue , P Barry , Rush University Medical Center, Chicago, IL |
SU-I-GPD-T-159 | A System Theoretic Process Analysis for High-Dose Rate Tandem and Ovoid Brachytherapy A Pegram*, A Yock, Vanderbilt University Medical Center, Nashville, TN. |
SU-K-209-1 | A High-Performance 3 Points Plastic Scintillator Dosimeter for HDR Brachytherapy: Conception, Development and Characterization H Linares Rosales1,2*, L Archambault1,2 , S Beddar3 , L Beaulieu1,2 , (1) CHU de Quebec-Universite Laval, Quebec, Quebec, (2) Departement de physique and University Laval Cancer Research Centre, Quebec, Canada, (3) UT MD Anderson Cancer Center, Houston, TX |
SU-K-209-2 | Brachytherapy Plan Quality Evaluation of Three-Dimensional Imaging Based Inverse Planning as Compared to Two-Dimensional Imaging Standard Load Planning T De La Fuente Herman*, E Schnell , S Thompson , S Ahmad , University of Oklahoma Health Science Center, Oklahoma City, OK |
SU-K-209-3 | Characterization and Validation of 3D Printed High Dose Rate Brachytherapy Applicators A Wiles1*, S Pokhrel1 , T Knewtson1 , Y Jia1 , D Goldbaum1 , M Ballo1,2 , E W Izaguirre1,2 , (1) university Tennessee Health Science Center, Methodist university Hospital, Memphis, TN, (2) West Cancer Center, Germantown, TN |
SU-K-209-5 | Dosimetric Evaluation of the First Ever Clinical Use of Venezia Advanced Gynecological Applicator for Combined Syed and Intracavitary HDR Brachytherapy Z Xu1*, B Traughber1,2 , J Muenkel1 , G Warrell1 , V Colussi1,2 , R Ellis1,2 , T Podder1,2 , (1) University Hospitals Cleveland Medical Center, Cleveland, Ohio, (2) Case Western Reserve University, School of Medicine, Cleveland, Ohio |
SU-K-209-7 | Simulated Performance of a Multi-Source Conformal Superficial Brachytherapy Device B Rogers1*, C Ferreira2 , J Lawrence3 , E Ehler4 , A Erdman5 , (1) University of Minnesota - Twin Cities, Minneapolis, MN, (2) University of Minnesota, Minneapolis, MN, (3) University of Minnesota - College of Veterinary Medicine, St. Paul, Minnesota, (4) University of Minnesota, Minneapolis, MN, (5) University of Minnesota - Twin Cities, Minneapolis, Minnesota |
SU-K-DBRA-1 | Can Cannabinoids Be Used to Enhance Therapeutic Efficacy During Radiotherapy? S Yasmin-Karim*, M Moreau , R Mueller , W Ngwa , Harvard Medical School, Boston, MA |
TH-AB-KDBRB1-9 | Using Machine Learning to Develop a Novel Error Detection Algorithm for HDR Brachytherapy D Sterling*, E Ehler , University of Minnesota, Minneapolis, MN |
TH-CD-KDBRC-5 | PET/CT-Ultrasound Registration for PET-Determined Prostate Brachytherapy S Sultana*, D Song , J Lee , Johns Hopkins University, Department of Radiation Oncology and Molecular Radiation Sciences, Baltimore, MD |
TH-CD-KDBRC-10 | An Iterative Deep-Learning Approach to Segment Sigmoid Colon H Jung*, C Shen , Y Gonzalez , N Qin , X Jia , The University of Texas Southwestern Medical Ctr, Dallas, TX |
TU-C1000-GePD-F3-1 | Dosimetric Evaluation of 3D Printed Materials for Ir-192 Brachytherapy E Ehler*, C Ferreira , D Mathew , D Sterling , C Wilke , University of Minnesota, Minneapolis, MN |
TU-C1000-GePD-F3-2 | Novel Nitinol Needle for Interstitial Rotating Shield Brachytherapy: Reconstruction Accuracy On CT and Ultrasound and Sterilization Effects K Patwardhan1*, Y Kim1 , J Koonce2 , S Mubeen2 , R Flynn1 ,(1) University of Iowa Hospitals and Clinics, Iowa City, IA, (2) University of Iowa, Iowa City, IA |
TU-C1000-GePD-F3-4 | Quantifying the Dosimetric Differences of AcurosBV with AAPM TG-43 Dose Calculation Algorithm in the Treatment of Intracavitary 192Ir HDR Brachytherapy Patients A Marsh*, J Feddock , D Cheek , J Molloy , D Pokhrel , University of Kentucky, Lexington, KY |
TU-C1000-GePD-F3-5 | Methodology for EBRT and HDR Brachytherapy Dose Composite for Clinical Plans of Gynecological Patients Z Xu1*, B Traughber1,2 , R Ellis1,2 , T Podder1,2 , (1) University Hospitals Cleveland Medical Center, Radiation Oncology, Cleveland, Ohio, (2) Case Western Reserve University, School of Medicine, Cleveland, Ohio |
TU-C1030-GePD-F3-1 | A Comparison Between Dosimetric Reporting Quantities for APBI Brachytherapy: MBDCA and Monte Carlo G Fonseca1 , F Verhaegen1 , S Thrower2 , K Gifford2*, (1) Maastro Clinic, Maastricht, ,(2) UT MD Anderson Cancer Center, Houston, TX |
TU-C1030-GePD-F3-2 | A Retrospective Comparison of TG-43 Calculated and Heterogeneity-Corrected Dose Distributions for 125I COMS Eye Plaques S Simiele*, A Choi , H Cho , C Lee , University of Michigan, Ann Arbor, MI |
TU-C930-GePD-F2-1 | Clinical Implementation of MRI-Based Planning Without Dedicated MRI Simulator for Cervical Cancer HDR Brachytherapy K Yang*, L de Souza Lawrence , D Jacob , F Mourtada , Christiana Care Hospital, Newark, DE |
TU-C930-GePD-F7-3 | Failure Modes and Effects Analysis (FMEA) of Intra OperativeRadiation Therapy (IORT) Treatments With Xoft EBx D Hoffman*, D Rash , J Urbanic , R Manger , I Dragojevic , UC San Diego, La Jolla, CA |
TU-E115-GePD-F6-3 | Development and Application of a High Precision Optical Guidance System for Customizable I-125 Eye Plaque Production K Nealon*, A Ayan , N Gupta , J Woollard , Ohio State Univ, Columbus, OH |
TU-K-DBRA-1 | Are Gold-Palladium Nanoparticles Vesicles Equivalent to Proton and 4He Ion in Cellular Dosimetry: A Monte-Carlo Study Based On Ex Vivo Imaging Y Ma1,2*, M Laprise-Peletier2 , J Lagueux1,2 , M Cote1,2 , M Fortin2 , L Beaulieu1,2 , (1) CHU de Quebec, Quebec, QC, (2) Universite Laval, Ville De Quebec, QC |
WE-AB-DBRA-1 | A Deep-Learning Approach Toward Automated Digitization of High Dose-Rate Brachytherapy Applicators H Jung1*, P Klages2 , C Shen3 , Y Gonzalez4 , K Albuquerque5 , X Jia6 , (1) University of Texas Southwestern Medical Center, Dallas, TX, (2) Memorial Sloan-Kettering Cancer Center, New York, NY, (3) University of Texas Southwestern Medical Center, Dallas, TX, (4) University of Texas Southwestern Medical Center, Dallas, TX, (5) University of Texas Southwestren Medical Center, Dallas, Tx, (6) University of Texas Southwestern Medical Center, Dallas, TX |
WE-AB-DBRA-3 | Deformable Registration to Align Prostate Brachytherapy Seeds Identified Using X-Ray Projections to MRI for Accurate Post-Implant Dosimetry WT Hrinivich1*, S Park2, D Song1, J Lee1, (1) Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, MD (2) Department of Diagnostic Radiology, Johns Hopkins University, Baltimore, MD |
WE-AB-DBRA-4 | Dose Measurements and Monte Carlo Simulations of a Directional LDR Brachytherapy Source Array M Aima*, L DeWerd, J Micka, C Hammer, J Hull, W Culberson, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, WI |
WE-AB-DBRA-5 | Effectiveness of Rotating Shield Brachytherapy for Prostate Cancer Dose Escalation and Urethral Sparing Q Adams1*, K Hopfensperger2 , Y Kim3 , X Wu4 , W Xu5 , H Shukla6 , J McGee7 , J Caster8 , R Flynn9 , (1) ,,,(2) University of Iowa, Iowa City, IA, (3) University Of Iowa, College of Medicine, Iowa City, IA, (4) University of Iowa, Iowa City, IA, (5) University of Iowa, Iowa City, IA, (6) OSF Saint Francis Medical Center, Peoria, IL, (7) OSF Saint Francis Medical Center, Peoria, IL, (8) University of Iowa, Iowa City, IA, (9) University of Iowa Hospitals and Clinics, Iowa City, IA |
WE-AB-DBRA-6 | Interactive Treatment Plan Optimization of High-Dose-Rate Brachytherapy for Gynecological Cancer Huan Liu1,3*, Chenyang Shen1 , Peter Klages2 , Ming Yang1 , Kevin Albuquerque1 , Zhen Wu3 , Junli Li3 , Xun Jia1 , (1) University of Texas Southwestern Medical Center, Dallas, TX, (2) Memorial Sloan-Kettering Cancer Center, New York, NY, (3) Tsinghua University, Beijing, China |
WE-AB-DBRA-8 | Microresolution Dosimetry System for Patient Specific Quality Assurance of Ocular Melanoma Eye Plaque Based Treatments S Pokhrel1*, A Wiles1 , T Knewtson1 ,Y Feng 1,2, M Ballo1,2 , E W Izaguirre1,2 , (1) university Tennessee Health Science Center,Methodist university Hospital, Memphis, TN., (2)West Cancer Center, Germantown, TN. |
WE-AB-DBRA-12 | Application of Civa-Sheet On Curved Surfaces I Veltchev*, R Price , X Chen , K Howell , J Meyer , C Ma , Fox Chase Cancer Center, Philadelphia, Pennsylvania |
WE-C1000-GePD-F4-2 | Assessment of Hypofractionated High Dose-Rate Brachytherapy for Cervical Cancerusing Radiobiology-Based Treatment Planning K Seeley1,2, I Hsu1 , T Hong2 , J A Cunha1*,(1) UC San Francisco, San Francisco, CA, (2) University of Pittsburgh, Pittsburgh, Pennsylvania |
WE-C1000-GePD-F4-4 | Validation of Acuros-Based Dose Distributions for Varian HDR Surface Applicator Set with Leipzig-Style Cones R Hunt*, D Cheek , J Molloy , D Pokhrel , University of Kentucky, Lexington, KY |
WE-C930-GePD-F7-1 | 3D Printed Patient-Specific Mould for HDR GYN Treatment S Wadi-Ramahi1*, N Jastaniyah1 , C Constantinescu1 , A Nobeh1 , F DeBlois2 , (1) King Faisal Specialist Hospital and Research Center, Riyadh, Saudi Arabia, (2) Montreal General Hospital, Montreal, QC |
WE-C930-GePD-F7-4 | Dose Calibration of Gafchromic EBT3 Film for Ir-192 Brachytherapy Source Using 3D-Printed ABS Plastic C Oare*, E Ehler , D Sterling , D Mathew , C Wilke , C Ferreira , University of Minnesota, Minneapolis, MN |
WE-FG-KDBRA1-11 | Nanotechnology Based Gel Dosimeter for in Vivo Use in Skin Brachytherapy A Rapchak1*, S Dutta2 , A Sadeghi3 , S Inamdar4 , T Sokolowski5 , C Page6 , S Sapareto7 , K Rege8 , K Subramaniam9 , (1) Banner MD Anderson Cancer Center, Gilbert, AZ, (2) Arizona State University, Tempe, AZ, (3) Banner MD Anderson Cancer Center, Gilbert, AZ, (4) Arizona State University, Tempe, AZ, (5) Banner MD Anderson Cancer Center, Gilbert, AZ, (6) Banner MD Anderson Cancer Center, Gilbert, AZ, (7) Banner - University Medical Center Phoenix, Phoenix, AZ, (8) Arizona State University, Tempe, AZ, (9) Arizona State University, Tempe, AZ |
WE-J-207-2 | A Knowledge-Based Multi-Criteria Optimization (kMCO) Algorithm for High Dose Rate (HDR) Brachytherapy S Cui1,2*, P Despres1,2 , L Beaulieu1,2 , (1) Universite Laval, Quebec, QC, (2) Centre Hospitalier Universitaire de Quebec, Quebec, QC |
WE-J-207-3 | AutoBrachy: A Streamlined Automated Treatment Planning, Quality Assurance, and Documentation System for Tandem-And-Ovoid High Dose-Rate Brachytherapy J Tan*, P Klages , C Shen , M Yang , K Albuquerque , X Jia , The University of Texas Southwestern Medical Ctr, Dallas, TX |