MENU

Click here to

×

Are you sure ?

Yes, do it No, cancel

DISCLAIMER:
Entry of taxonomy/keywords during proffered abstract submission was optional.
Not all abstracts will appear in search results.

Education | IM | IM/TH | Leadership | TH | show all

Taxonomy: TH- External beam- photons: Small/nonstandard field experimental dosimetry

MO-AB-SAN1-10Small Field Dosimetry: Detector Dependency On Output Factor and Off-Axis-Ratio Measurements for a Novel Radiosurgery System
D Pinnaduwage1*, S Srivastava1 , X Yan1 , S Jani1 , C Jenkins2 , G Weidlich2 , M Bodduluri2 , S Sorensen1 , (1) Barrow Neurological Institute (BNI) St. Joseph's Hospital & Medical Center, Phoenix, AZ, (2) Zap Surgical Systems, Inc., San Carlos, CA
PO-GePV-P-28Calculation Grid Size Effects On Dose Under GRID "mini" Beam in TPS
M Xu1*, (1) Northwestern Medicine Cancer Center, Geneva, IL
PO-GePV-T-301A Compound Refractive Lens for Radiation Oncology Megavoltage X-Rays
R Rademacher1*, (1) Genesis Healthcare Partners, San Diego, CA
PO-GePV-T-314Dosimetric Performance of Two Novel Microchambers for Relative Measurements During Linac Commissioning
T Tekin*, B Poppe , H Looe
PO-GePV-T-321Evaluation of a New Plastic Scintillation Detector for Stereotactic Radiosurgery Applications
D Jacqmin*, J Miller , Z Labby , A Shepard , B Barraclough , University of Wisconsin, Madison, WI
SU-E-221AB-3Experimental Evaluation of the Dosimetric Impact of Intrafraction Prostate Rotations Using Film Measurement with a 6 DoF Robotic Arm
K Shi1*, A Dipuglia2 , J Booth2 , S Alnaghy3 , A Kyme1 ,P Keall1 , D Nguyen1 , (1) University of Sydney, Sydney, NSW, (2) Royal North Shore Hospital, Marrickville, NSW, (3) University of Wollongong, Wollongong, NSW
SU-K-SAN1-4On the Discrepancy of Experimental and Monte-Carlo Simulated Dose Response of the MicroDiamond Detector: The Role of Charge Imbalance in Structural Components
HK Looe1*, D Poppinga2 , R Kranzer2 , I Buesing1 , T Tekin1 , AB Ulrichs1 , B Delfs1 , D Vogt2 , J Wuerfel2 , B Poppe1 , (1) University Clinic for Medical Radiation Physics, Medical Campus Pius Hospital, Carl von Ossietzky University, Oldenburg, Germany (2) PTW Freiburg, Germany
SU-K-SAN1-7Characterization of Small Field Output Factors for a Medical Linear Accelerator with a Dual-Layer Stacked and Staggered MLC System
P Irmen*, T Li , University of Pennsylvania, Philadelphia, PA
TH-BC-301-5Development and Implementation of a Small Field Calibration Procedure for a Novel Stereotactic Radiosurgery Device Utilizing TG-21 & IAEA TRS 483
S Becker*, E Nichols , B Yi , Univ. of Maryland School Of Medicine, Baltimore, MD