MENU

Click here to

×

Are you sure ?

Yes, do it No, cancel

DISCLAIMER:
Entry of taxonomy/keywords during proffered abstract submission was optional.
Not all abstracts will appear in search results.

Education | IM | IM/TH | Leadership | TH | show all

Taxonomy: TH- Brachytherapy: Calibration

MO-E115-GePD-F6-3Error Detection in End-To-End Test for CT-Based HDR Brachytherapy Using a Normoxic N-Vinylpyrrolidone Polymer Gel Dosimeter
H Tachibana1*, Y Watanabe2 , S Mizukami2 , T Maeyama2 , T Terazaki3 , R Uehara1 , T Akimoto1 , (1) National Cancer Center Hospital East, Kashiwa, ,(2) Kitasato University, Sagamihara, ,(3) Yokohama City Minato Red Cross Hospital, Yokohama,
MO-E115-GePD-F6-6Development of Volume-Based Second-Check Dose Calculation Software for Image-Guide Adaptive Brachytherapy
S Kang1*, J Chung2 , K Kim1 , J Park3 , T Suh1 , J Park4 , (1) Department of Biomedicine & Health Sciences, Research Institute of Biomedical Engineering, College of Medicine, the Catholic University of Korea,(2) Department of Radiation Oncology, Seoul National University Boramae Medical Center,(3) Deapartment of Radiation Oncology, University of Florida, Gainesville, FL,(4) Department of Radiation Oncology, Washington University in St. Louis, St. Louis, MO
PO-GePV-T-1Investigation of the Directional Dependence of the Detector Response Near a 192Ir Brachytherapy Source
K Buesing*, A Schoenfeld , B Poppe , Medical Campus Pius Hospital, Carl von Ossietzky University, Oldenburg, Germany
PO-GePV-T-2Improvements in Efficiency and Accuracy for HDR Source Positioning Through the Use of a High Resolution Camera Localization System
D Nicewonger*, S Stathakis , N Papanikolaou , N Kirby , D Saenz , P Myers , M Fakhreddine , K Rasmussen , University of Texas HSC SA, San Antonio, TX
PO-GePV-T-3A Semi-2D TG-43 Formula for Accurate In-House Verification of High-Dose-Rate Brachytherapy Dose Calculation
Q Fan*, D Zheng , S Wang , C Lin , C Enke , S Zhou , University of Nebraska Medical Center, Omaha, NE
PO-GePV-T-6Evaluation of a Time-Based Plan Check Method for Rotte 'Y' and Venezia Brachytherapy Treatments
J Hansen*, R Das , University of Wisconsin, Madison, WI
SU-E-301-3Dosimetric Impact of Silastic Insert Thickness in COMS Eye Plaque for I-125 Brachytherapy
C Oare*, D Sterling , K Dusenbery , D Koozekanani , C Ferreira , University of Minnesota, Minneapolis, MN
SU-E-301-6Time-Resolved Gamma Imaging of High Dose Rate (HDR) Brachytherapy Source Positions
K Jones*, Y Liao , Z Grelewicz , D Bernard , J Turian , Rush University Medical Center, Chicago, IL
WE-C1030-GePD-F4-5Commissioning of Advanced Collapsed Cone Engine Algorithm for Brachytherapy
J Swamidas*, S Parida , K Joshi , R Phurailatpam , S Panda , S Pradhan , Department of Radiation Oncology, ACTREC, Tata Memorial Center, Navi Mumbai, Maharashtra, India