MO-AB-221AB-7 | Real-Time Direct Diaphragm Tracking During Lung Cancer Radiotherapy N Hindley1*, P Keall2 , J Booth3 , C Shieh4 , (1) ACRF Image X Institute, Sydney, ,(2) University of Sydney, Sydney, NSW, (3) Royal North Shore Hospital, Marrickville, NSW, (4) The University of Sydney, Eveleigh, |
MO-E115-GePD-F8-1 | A Method to Measure the Alignment of the X-Ray Field, Image Receptor, and Displayed Image On Fluoroscopic Systems J Steiner*, M Vanderhoek , M Vaya , Henry Ford Health System, Detroit, MI |
MO-E115-GePD-F8-2 | Comparison of Patient Fluoroscopic Water-Equivalent Thicknesses to a Common Patient-Equivalent Phantom G Fong*, K Wunderle , Cleveland Clinic Foundation, Cleveland, OH |
MO-I345-GePD-F8-5 | Ten Years of Interventional Cardiology Catheterization Therapy Procedures in a Large Territory Hospital. A Retrospective Analysis of High Maximum Patient Skin Doses to Evaluate Trends V Chatonidis1, V Tsapaki2*, P Karaiskos1, E Pantelis1, S Patsilinakos2, S Kottou1, (1) National and Kapodistrian University of Athens, Faculty of Medicine, Medical Physics Laboratory, Athens, Greece, (2) Konstantopoulio General Hospital, Nea Ionia, Athens, Greece |
PO-GePV-P-16 | Intervention-Training for Pediatric General Fluoroscopy: Can It Make a Difference? E Somasundaram , S Brady , S Kraus , K Strauss*, Cincinnati Childrens Hospital Med Ctr, Cincinnati, OH |
PO-GePV-P-53 | Effect of Angulation and Table Position On Patient Peak Skin Dose (PSD) Evaluations From Fluoroscopy-Guided Intervention Procedures (FGIPs) M Hoerner*, A Mustafa , D Vergara , Department of Radiology and Biomedical Imaging Yale School of Medicine and Yale New Haven Hospital, New Haven, CT |
SU-F-225BCD-2 | Evaluation of Tracking Accuracy Using Synthetic Color Fluoroscopic Images Based On the Deep Learning for Real-Time Tumor-Tracking Radiotherapy T Shiinoki*, Y Yuasa , K Fujimoto , Yamaguchi University, Ube |
SU-F-225BCD-6 | Using Neural Net Object Detection for Fiducial Tracking D Sawkey1*, H Mostafavi1, L Cervino2, (1) Varian Medical Systems, Palo Alto, CA (2) UC San Diego, La Jolla, CA |
SU-I430-GePD-F5-5 | Motion Tracking Using Implanted Fiducials and Template Matching and Triangulation in Fluoroscopic Images for Pancreatic Cancer Stereotactic Body Radiation Therapy O Oderinde1*, H Mostafavi2 , D Simpson1 , J Murphy1 , L Cervino1 , (1) University of California San Diego, San Diego, CA, (2) ,Palo Alto, CA, |
SU-L-303-2 | Convolution Neural Network Based X-Ray Dose Reduction Technique for Fluoroscopy and Angiography S Setlur Nagesh , D Bednarek , S Rudin*, Canon Stroke and Vascular Research Center, Univ. at Buffalo (SUNY) , Buffalo, NY |
SU-L-303-3 | Evaluation of the Accuracy of Interpolation of Room Scatter Distributions for Display During Fluoroscopic Procedures C Guo*, S Sun , J Troville , S Rudin , D Bednarek , Univ. at Buffalo (SUNY) School of Med., Buffalo, NY |
TH-BC-304-9 | Staff Member Tracking in a Virtual-Reality Scattered-Radiation Display of a Fluoroscopic Interventional Room J Troville*, C Guo , S Rudin , D Bednarek , (1) Univ. at Buffalo (SUNY) School of Med., Buffalo, NY, (2) Canon Stroke and Vascular Research Center, Buffalo, NY |
TH-D-302-7 | Skin Dose Variation with Incident X-Ray Beam Angle S.H. Sun*, C Guo , S Rudin , D Bednarek , Univ. at Buffalo (SUNY) School of Med., Buffalo, NY |
TU-C-PinS-4 | Three-Dimensional Tumor Position Estimation Using Image Features On Orthogonal KV X-Ray Projections: Comparison of Two Feature Extraction Algorithms S Anbo1*, M Nakamura1 , N Mukumoto1 , T Ono1 , T Mizowaki1 , (1) Kyoto University |
TU-C930-GePD-F8-2 | Description and Validation of An Acquisition-Specific Parameterized Approach to Peak Skin Dose Calculation for Fluoroscopy Guided Interventional Procedures D Vergara*, M Hoerner, A Mustafa, Department of Radiology and Biomedical Imaging, Yale School of Medicine and Yale New Haven Hospital, New Haven, CT |
TU-C930-GePD-F8-3 | Initial Experience in Measuring Input Detector Exposure Rates for Siemens Artis Pheno System Configured with a New Automatic Dose Regulation Feature J Dave1*, (1) Thomas Jefferson University, Philadelphia, PA |
TU-C930-GePD-F8-4 | On Efforts to Correct Discrepancy Between System-Reported Air Kerma Rates and Measured Air Kerma Rates for Ziehm Vision RFD 3D C-Arm System J Dave1*, (1) Thomas Jefferson University, Philadelphia, PA |
TU-E-221CD-0 | Radiation Protection for Fluoroscopically-Guided Interventional Procedures: Patient Dose and Radiobiology K Wunderle1*, R Stewart2*, K Wunderle3*, (1) Cleveland Clinic Foundation, Broadview Hts, OH, (2) University of Washington, Seattle, WA, (3) Cleveland Clinic Foundation, Broadview Hts, OH |
TU-F115-GePD-F2-3 | Preventing Patient Skin Erythema in CT Fluoroscopy-Guided Biopsies Y Gao1*, U Mahmood1 , X Xu2 , L Dauer1 , (1) Memorial Sloan Kettering Cancer Center, New York, NY, (2) Rensselaer Polytechnic Inst., Troy, NY |
TU-K430-CAMPUS-F1-4 | Radiation Dose Audit for Fluoroscopy Procedures Performed with Mobile C-Arms Or Performed in Radiography/fluoroscopy (R/F) Suites: Data From a Tertiary and Quaternary Care Hospital A Tahir1,2*, J Dave2 , (1) Rowan University School of Osteopathic Medicine, Stratford, NJ, (2) Thomas Jefferson University, Philadelphia, PA |