Keywords: validation
MO-AB-SAN1-11Treatment Planning System and Beam Data Validation for a Novel Self-Shielded Stereotactic Radiosurgery System (SRS)
S Srivastava1*, S Jani1 , D Pinnaduwage1 , X Yan1 , M Bodduluri2 , S Sorensen1 , (1) Barrow Neurological Institute (BNI) St. Joseph's Hospital & Medical Center, Phoenix, AZ, (2) Zap Surgical Systems, Inc., San Carlos, CA
PO-GePV-T-117Quality Assurance Parameters in Image Registration
K Maloney1*, (1) ,Holden, MA
PO-GePV-T-170Verification Results Analysis of IMRT Plan Based On Disease Differences and Establishment of Gamma Threshold of Each Disease
X Lin*, Z Li , Q Qiu , Y Yin , Shandong Cancer Hospital Affiliated to Shandong University, Jinan, Shandong
PO-GePV-T-272Efficient and Inclusive Linear Accelerator Beam Data Verification
M Schmidt*, N Knutson , A Price , B Sun , G Hugo , E Laugeman , E Pryser , S Mutic , F Reynoso , Washington University School of Medicine, St. Louis, MO
PO-GePV-T-390Validation of a Preclinical KV Treatment Planning System for Small Animal Image-Guided Radiotherapy
A Anvari*, A Sawant , University of Maryland School of Medicine, Baltimore, MD
TH-A-301-8Monte Carlo Simulation and Validation of a Novel Yttrium-90 Source for Use in a Conformal Superficial Brachytherapy Device
B Rogers*, P Alaei , J Chmura , E Ehler , J Lawrence , C Wilke , C Ferreira , University of Minnesota, Minneapolis, MN
TH-A-SAN2-1Machine Learning for Patient-Specific Quality Assurance of VMAT: Prediction and Classification Accuracy
J Li1*, L Wang2 , X Zhang1 , L Liu1 , J Li1 , M Chan3 , J Sui2 , R Yang1 , (1) Peking University Third Hospital, Beijing, (2) Institute of Automation, Chinese Academy of Sciences, Beijing, (3) Memorial Sloan Kettering Cancer Center, Basking Ridge, NJ
TU-AB-225BCD-1BEST IN PHYSICS (MULTI-DISCIPLINARY): A New Positron Emission Mammography (PEM) Ultrasound-Guidance Device for Breast Biopsy
C Park1,2,*, J Bax2, A Fenster1,2, (1) Western University Ontario, London, ON, Canada, (2) Robarts Research Institute, London, ON, Canada
TU-C1030-GePD-F8-6X-Ray Image Identification for Single Patient Based On Artificial Intelligence
z Wang*, J Qiu , L Shi , W Lu , Q Sun , q Meng , Taishan Medical University, Taian, Shandong
TU-C930-GePD-F3-1Validation of a Laying Down Technique for Total Skin Irradiation Using Monte Carlo
R Li*, Q Wu , Duke University, Durham, NC
TU-C930-GePD-F8-4On Efforts to Correct Discrepancy Between System-Reported Air Kerma Rates and Measured Air Kerma Rates for Ziehm Vision RFD 3D C-Arm System
J Dave1*, (1) Thomas Jefferson University, Philadelphia, PA
TU-J345-GePD-F6-1Correlation of Deformation Vector Field Error and Contour-Based Metrics in Unimodal Deformable Image Registration
L Shi1*, S Barley2 , S Benedict3 , J Qiu1 , Y Rong3 , (1) Taishan Medical University, Taian, ,(2) Oncology Systems Limited (OSL), Shrewsbury, ,(3) UC Davis Cancer Center, Sacramento, CA
TU-J345-GePD-F6-4New Approach for Automatic and Patient-Specific Evaluation of Multi-Modality Deformable Image Registration Accuracy as Tested On Halcyon's Megavoltage Cone Beam CT System
Y Huang*, Y Zhang** , Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing), Peking University Cancer Hospital & Institute, Beijing, 100142 **Corresponding Author:Y Zhang email:zhangyibao@pku.edu.cn
WE-J-304-7Dosimetric Verification for In-Vivo Radiobiology Experiments Using a 3D-Printed Mouse
N Esplen*, E Alyaqoub , M Bazalova-Carter , University of Victoria, Victoria, BC