MENU

Click here to

×

Are you sure ?

Yes, do it No, cancel

DISCLAIMER:
Entry of taxonomy/keywords during proffered abstract submission was optional.
Not all abstracts will appear in search results.

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # | show all

Keywords: scintillators
MO-E115-GePD-F4-2Investigation of the Thermal Dependence of a Commercial Plastic Scintillation Detector System in Photon and Electron Beams
R Kolany1, C Zeringue2, W Culberson1, (1) Dept of Med Phys, School of Medicine and Public Health, Univ of Wisc - Madison, Madison, WI (2) ZModDynamics LLC, Fulshear, TX
MO-I345-GePD-F3-3Characterization of Spectral Changes with Measurement Geometry and Magnetic Field Strength in Light Guides Used for Scintillation Dosimetry
E Simiele1*, R Kapsch2 , U Ankerhold2 , W Culberson1 , L DeWerd1 , (1) Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, WI, (2) Physikalisch-Technische Bundesanstalt, Braunschweig, Germany
PO-GePV-T-79Comprehensive and Efficient Spot Size and Position Quality Assurance for Proton Spot Scanning System
D Robertson1*, J Shen1 , (1) Mayo Clinic Arizona, Phoenix, AZ
PO-GePV-T-81Radioluminescent Fiber Optic Dosimeters for Proton Therapy
A Darafsheh*, Washington University School of Medicine, St. Louis, MO
PO-GePV-T-265Scintillator Optical Imaging for Co-60 Irradiator Quality Assurance Testing
I Tendler1*, J Bredfeldt2, R Zhang3 , P Bruza1 , M Jermyn1, B Pogue1,4,5 , D Gladstone1,5,6, (1) Thayer School of Engineering, Dartmouth College, Hanover, NH, (2) Brigham and Women's Hospital, Boston, MA (3) Emory Proton Therapy Center, Johns Creek, GA, (4) DoseOptics LLC, Lebanon, NH, (5) Dept. of Medicine, Geisel School of Medicine, Dartmouth College, Hanover, NH (6) Norris Cotton Cancer Center, Dartmouth-Hitchcock Med. Ctr., Lebanon, NH,
PO-GePV-T-321Evaluation of a New Plastic Scintillation Detector for Stereotactic Radiosurgery Applications
D Jacqmin*, J Miller , Z Labby , A Shepard , B Barraclough , University of Wisconsin, Madison, WI
SU-E-SAN1-8Preliminary Characterization of a Stemless Plastic Scintillation Detector
M Hupman1*, T Monajemi1,2,3 , I Hill1 , A Syme1,2,3 , (1) Department of Physics & Atmospheric Science, Dalhousie University, Halifax, NS, B3H 4R2, Canada (2) Department of Radiation Oncology, Dalhousie University, Halifax, NS, B3H 4R2, Canada (3) Department of Medical Physics, Nova Scotia Health Authority, QEII Health Science Centre, Halifax, NS, B3H 1V7, Canada
SU-I330-GePD-F6-2Development of Detector for Ultra-Fast Beam Diagnostics in Proton Radiotherapy
V Iakovenko1,2*, D Jaffray2,3,4 , (1) Sunnybrook Health Sciences Centre, Toronto, ON, (2) University of Toronto, Toronto, ON, (3) University Health Network, Toronto, ON, (4) Techna Institute, Toronto, ON
SU-KL-304-9Validation of a Non Invasive Positron Detector for Use with Dynamic PET Under Clinical Conditions
L Carroll1*, G KERTZSCHER2 , E Croteau3 , O Sarrhini4 , R Lecomte5 , S Abbasi Nejad Enger6 , (1) McGill University, Montreal, QC, (2) Aarhus University Hospital, Aarhus, ,(3) Sherbrooke University, Sherbrooke, ,(4) Sherbrooke University, Sherbrooke, ,(5) Sherbrooke University, Sherbrooke, ,(6) McGill University, Montreal, QC
SU-L-SAN1-1Characterization of a Novel Scintillator Imaging-Based Surface Dosimeter
I Tendler1*, P Bruza1 , M Jermyn2 , X Cao1 , B Williams3,4 , L Jarvis3,4 , B Pogue1,2,3 , D Gladstone1,3,4 , (1) Thayer School of Engineering, Dartmouth College, Hanover, NH, (2) DoseOptics LLC, Lebanon, NH, (3) Dept. of Medicine, Geisel School of Medicine, Dartmouth College, Hanover, NH (4) Norris Cotton Cancer Center, Dartmouth-Hitchcock Med. Ctr., Lebanon, NH, (5)
TH-A-301-6IViST: A Platform for Real-Time In Vivo Source Tracking in HDR Brachytherapy
H LINARES ROSALES 1,2*, J JOHANSEN3 , A CANTIN1 , G KERTZSCHER3 , L Archambault1,2 , K Tanderup3 , L Beaulieu1,2 , S Beddar4 , (1) CHU de Quebec-Universite Laval, Quebec, Canada, (2) Physics department and Universite Laval Cancer Research Centre, Quebec, Canada ,(3) Department of Oncology, Aarhus University Hospital, Denmark, (4) The University of Texas MD Anderson Cancer Center, Houston, United States
TH-BC-301-8Taking Advantage of An Optical Design Software to Generalize and Simplify the Conception Process of 3D Scintillation Dosimetry Systems
M Rilling1,2,3,4*, S Thibault1,2 , L Archambault1,3,4 , (1) Departement de physique, de genie physique et d'optique, Universite Laval, Quebec, QC, Canada (2) Centre d'optique, photonique et laser, Quebec, QC, Canada (3) Centre de recherche sur le cancer, Quebec, QC, Canada (4) Centre de recherche du CHU de Quebec-Universite Laval - Axe oncologie, Quebec, QC, Canada
TU-C930-GePD-F4-1Evaluation of a Plastic Scintillation Detector for Commissioning Data Acquisition in An MR-Guided Linear Accelerator
B Barraclough*, K Mittauer , D Jacqmin , A Antolak , P Yadav , University of Wisconsin, Madison, WI
TU-C930-GePD-F4-4Characterizing the Response of a 3D Plastic Scintillation Dosimeter Under Discrete Deformations
E Cloutier1,2*, L Archambault1,2 , L Beaulieu1,2 , (1) Centre Hospitalier Universitaire de Quebec, Quebec, Qc, ,(2) Department of physics, physics engeneering and optics, Universite Laval, Quebec, Qc
TU-HI-SAN4-6Cherenkov Emission and Scintillation Imaging for Surface Dosimetry and Interfraction Anatomy Tracking in Head and Neck Radiotherapy
D Alexander1*, I Tendler1 , P Bruza1 , D Gladstone1,2,3 , P Schaner2,3 , L Jarvis2,3 , B Pogue1,2,3 , (1) Thayer School of Engineering, Dartmouth College, Hanover, NH, (2) Geisel School of Medicine, Dartmouth College, Hanover, NH, (3) Norris Cotton Cancer Center, Dartmouth Hitchcock Medical Center, Lebanon, NH
TU-HI-SAN4-8Remote, Real-Time Optical Imaging of Small Beamlets in Radiotherapy
M Ashraf1*, P Bruza1 , N Nelson2 , D Gladstone1,2 , B Williams1,2 , L Jarvis2 , B Pogue1 ,2(1) Dartmouth College, Hanover, NH,(2) Dartmouth-Hitchcock Med. Ctr., Lebanon, NH,
WE-AB-225BCD-4Convolutional Neural Network for Centroiding and Depth-Of-Interaction Localization in PET
A LaBella*, W Zhao , AH Goldan , Stony Brook University, Stony Brook, NY
WE-C1000-GePD-F4-2Comparison of W1 and W2 Plastic Scintillation Detectors with Small Field Output Factors
J McKay*, S Petro , M Axente , B Velasco , C Liu , Erlanger Health System, Chattanooga, TN
WE-C1000-GePD-F4-6Electron Energy Spectrometry in Orthovoltage Beams Using Lead Doped Plastic Scintillators
H Nusrat1*, G Pang1,2,3 , A Sarfehnia1,2,3 , (1) Department of Physics, Ryerson University, Toronto, ON, (2) Department of Radiation Oncology, University of Toronto, Toronto, ON, (3) Department of Medical Physics, Odette Cancer Centre, Sunnybrook Health Science Center, Toronto, ON
WE-C1030-GePD-F6-2Automating Quality Assurance of MLC Via Real-Time Radioluminescent Imaging Technique
M Jia1*, C Jenkins2 , Y Yang3 , B Han4 , L Xing5 , (1) Stanford University, Palo Alto, CA, (2) Stanford University, Palo Alto, CA, (3) Stanford University Cancer Center, Stanford, CA, (4) Stanford Univ School of Medicine, Stanford, CA, (5) Stanford University School of Medicine, Stanford, CA
WE-FG-304-2Development of An Image Acquisition Method for Optical Cameras to Efficiently Capture Pencil Beams Used in Proton Therapy
C Darne*, F Alsanea , Y Hojo , S Beddar , The UT MD Anderson Cancer Center, Houston, TX