Keywords: pencil beam algorithms
MO-C930-GePD-F3-4Evaluation of a Modified Pencil Beam Algorithm Dose Calculation in the Presence of Intensity Modulators for Intensity Modulated Bolus Electron Beam Conformal Therapy
E Hilliard1,2*, R Carver2 , K Hogstrom3 , K Erhart4 , (1) Medical University of South Carolina, Charleston, SC, (2) Mary Bird Perkins Cancer Center, Baton Rouge, LA, (3) Mary Bird Perkins Cancer Center, Baton Rouge, LA, (4) .decimal LLC, Sanford, FL
PO-GePV-T-70Impact of Dose Calculation Engine On Field Patching in Spot Scanning Proton Therapy
M Chen1,2*, P Yepes2,3 , F Poenisch2 , Y Li2 , C Xu1 , X He1 , J Chen1 , N Sahoo2 , H Li2 , X Zhu2 , X Zhang2 , (1) Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai,China, (2) MD Anderson Cancer Center, Houston, TX,(3) Rice University, Houston, TX
SU-I300-GePD-F7-5An Optimized Approach for Spot Placement in Pencil Beam Scanning (PBS) Proton Therapy
M Rehman1*, K Erhart2 , S Meeks3 , P Kelly4 , O Zeidan5 , (1) University of Central Florida, Orlando, FL, (2) .decimal LLC, Sanford, FL, (3) UF Health Cancer Center at Orlando Health, Orlando, FL, (4) UF Health Cancer Center at Orlando Health, Orlando, FL, (5) UF Health Cancer Center at Orlando Health, Orlando, FL
SU-I430-GePD-F7-2Pencil Beam Dose Algorithm Based On Dual Depth Dose - Lateral Profile Model for Intensity Modulated Proton Therapy