MENU

Click here to

×

Are you sure ?

Yes, do it No, cancel

DISCLAIMER:
Entry of taxonomy/keywords during proffered abstract submission was optional.
Not all abstracts will appear in search results.

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # | show all

Keywords: let
PO-GePV-T-78Silica-Based Optical Fibers for Proton Therapy Dosimetry
C Hoehr1*, A Morana2, O Duhamel3, B Capoen4, M Trinczek1, P Paillet3, C Penner5, D Muecher1, C Duzenli5, M Bouazaoui4, G Bouwmans4, A Cassez4, Y Ourdane2, A Boukenter2, H El Hamzaoui4, S Girard2,(1) TRIUMF, Vancouver, BC, (2) University of St. Etienne, France, (3) CEA, Toulouse, France, (4) University of Lille, France, (5) BC Cancer, Vancouver, Canada
PO-GePV-T-81Radioluminescent Fiber Optic Dosimeters for Proton Therapy
A Darafsheh*, Washington University School of Medicine, St. Louis, MO
PO-GePV-T-97LET-Guided Planning Strategies for Localized Prostate Cancer in Proton Therapy
M Chen1,2*, P Yepes2,3 , W Cao2 , F Poenisch2 , Y Li2 , C Xu1 , X He1 , J Chen1 , N Sahoo2 , H Li2 , X Zhu2 , X Zhang2 , (1) Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China,(2) MD Anderson Cancer Center, Houston, TX, (3) Rice University, Houston, TX
PO-GePV-T-112Examining the Impact of Beam Intersection Angles On CNS Toxicities in Pediatric Proton Therapy Patients
A Faught*, J Becksfort , T Merchant , J Lucas , St Jude Children's Research Hospital, Memphis, TN
PO-GePV-T-114Monte Carlo Simulation and Sensitivity Analysis of a Gantry-Mounted Passively Scattered Proton System
M Baradaran1*, F Reynoso2 , M Prusator3 , T Zhao4 , (1) Washington University, Saint Louis, MO, (2) Washington University in St. Louis, St. Louis, MO, (3) ,Kirkwood, MO, (4) Washington University School of Medicine, St. Louis, MO
PO-GePV-T-124Wavelet-Based Signal Processing Approach for Protoacoustic Measurement in Proton Range Verification
J Sohn1*, W Nie2 , X Yang3 , X He4 , J Zhou5 , S Avery6 , T Liu7 , (1) Emory University, Atlanta, GA, (2) University of Nebraska, Omaha, NE, (3) Emory University, Atlanta, GA, (4) Emory University, Lilburn, GA, (5) Emory University, Atlanta, GA, (6) UNIVERSITY OF PENNSYLVANIA, Sicklerville, NJ, (7) Emory University, Atlanta, GA
PO-GePV-T-403Track Structure Simulation of DNA Damage Induced by Electron, Proton, and Alpha Particles
R Taleei1*, M Mokari2 , (1) University of Virginia, Charlottesville, VA, (2) University, Behbahan, 10
SU-F-SAN1-8New Hybrid 3D Analytical Linear Energy Transfer Calculation Algorithm Based On the Pre-Calculated Data From Monte Carlo Simulations
W Deng*, X Ding , J Younkin , S Schild , J Shen , M Bues , W Liu , Mayo Clinic Arizona, Phoenix, AZ
SU-L-221CD-4Feasibility of Different Prognostic Prediction Models for Lung Cancer Stages I-IIIB Based On Radiomic Signatures
K Ninomiya*, H Arimura , Kyushu UniversityFukuoka
TU-AB-SAN1-5First Report On Methodology Development and Validation of LET Computed in a Monte Carlo Dose Engine of a Commercial Treatment Planning System
D Wagenaar1*, T Tran2 , A Meijers1 , D Bolst2 , B James2 , M Povoli3 , A Kok3 , E Traneus4 , M van Goethem1 , J Langendijk1 , A Rosenfeld2 , S Both1 , (1) University of Groningen, University Medical Center Groningen, Groningen, the Netherlands (2) University of Wollongong, Wollongong, Australia (3) SINTEF, Oslo, Norway (4) RAYSEARCH LABORATORIES AB, Stockholm, Sweden
TU-F115-GePD-F4-1A Test of the Hypothesis That the Linear-Quadratic (LQ) Model Parameter Beta Decreases with Increasing Particle Linear Energy Transfer (LET)
D Wang*, R Stewart , University of Washington , Seattle, WA