MENU

Click here to

×

Are you sure ?

Yes, do it No, cancel

DISCLAIMER:
Entry of taxonomy/keywords during proffered abstract submission was optional.
Not all abstracts will appear in search results.

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # | show all

Keywords: hdr
MO-C930-GePD-F4-2Measuring Dose Enhancement From Gold Nanoparticles in An 192Ir Setup
N Bassiri1*, T Gray2 , S David2 , D Patel2 , A Locker2 , K Rasmussen1 , N Papanikolaou1 , K Mayer2 , N Kirby1 , (1) UT Health at San Antonio (2)University of Texas at San Antonio
MO-C930-GePD-F4-5Spatial, Dosimetric, and Radiobiological Robustness of Template-Based Interstitial High-Dose-Rate Gynecologic Brachytherapy
M Ostyn1*, A Burke2, E Fields1, D Todor1, (1) Virginia Commonwealth University, Richmond, VA, (2) Georgetown University, Washington, DC
PO-GePV-P-54Commissioning of HDR Valencia Applicators
P Aryal*, S Chen , M Agarwal , J Zhou , G Lasio , University of Maryland School of Medicine, Baltimore, MD
PO-GePV-P-70Study On the Brachytherapy Applicator of Vaginal Cylinder Based On 3D Printing Technology
L Yu1*, B Yang1 , X Liu1 , T Pang1 , N Liu1 , J Qiu1 , (1) Department Of Radiation Oncology,Peking Union Hospital,Chines Academy of Medical Sciences,Peking Union Medical College,Beijing 100730,China
PO-GePV-T-3A Semi-2D TG-43 Formula for Accurate In-House Verification of High-Dose-Rate Brachytherapy Dose Calculation
Q Fan*, D Zheng , S Wang , C Lin , C Enke , S Zhou , University of Nebraska Medical Center, Omaha, NE
PO-GePV-T-12Demonstration of the Need for An Air-Kerma Rate Standard for the Newest Model of the Xoft Axxent TM Source
A Walter*, D Anderson , L DeWerd, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, WI
PO-GePV-T-14Planning Margins and Inter-Fraction Motion for Inpatient Interstitial HDR Brachytherapy
W Campbell*, C Fisher , M Miften , L Schubert , University of Colorado School of Medicine, Aurora, CO
PO-GePV-T-16Observation Of Short-Term Efficacy In Image-Guided Adaptive Intraluminal High-Dose-Rate Brachytherapy For The Treatment Of Malignant Obstructive Jaundice
L Sun*, W Hu , J Zhao , R Jiang , H Huang ,
PO-GePV-T-17Dosimetric Evaluation of Multi-Channel Cylinders for High Dose Rate Vaginal Cuff Brachytherapy Using a Cylindrical Target Volume
S Kucuker Dogan*, Z Kang , J Cates , H Zhang , Northwestern Memorial Hospital, Chicago, IL
PO-GePV-T-30Inter-Observer Variabilities in Applicator Reconstruction and the Dosimetric Impact in HDR Gynecological Brachytherapy
R Zakariaee1,2*, J Borg3 , A Beiki-Ardakani3 , R Weersink1,3,4 , (1) Department of Radiation Oncology, University of Toronto, Toronto, ON, (2) Radiation Medicine Program, Stronach Regional Cancer Center, Newmarket, ON, (3) Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, ON, (4) Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, ON
SU-E-301-5The Impact of Dose Heterogeneity Corrections for Post-Mastectomy Chest-Wall Boost Treatments Using HDR Plesiotherapy
M Altman1*, T Mazur2 , J Garcia-Ramirez3 , H Li4 , J Hilliard5 , I Zoberi6 , J Zoberi7 , (1) Washington University School of Medicine, St. Louis, MO, (2) Washington University School of Medicine, St Louis, MO, (3) Washington University School of Medicine, St. Loius, ,(4) Washington University School of Medicine, St. Louis, MO, (5) Washington University School of Medicine ,St. Louis, MO, (6) Washington University School of Medicine, St. Louis, MO, (7) Washington University School of Medicine, St. Louis, MO
SU-F-301-1Comparison of Acuros BV and TG-43 Dose Calculation for HDR Skin Brachytherapy with Flap Applicator in Heterogeneous Media
H Kang*, R Patel , S Gros , Loyola University Medical Center, Chicago, IL
SU-F-301-3Enabling Rotating Shield Brachytherapy with Efficient Yb-169 High-Dose-Rate Brachytherapy Source Production by Re-Activation
R Flynn1*, Q Adams1, K Hopfensperger2, X Wu1,3, W Xu3, Y Kim1, (1) Department of Radiation Oncology, The University of Iowa, Iowa City, IA, (2) Department of Biomedical Engineering, The University of Iowa, (3) Department of Electrical and Computer Engineering, The University of Iowa
SU-F-301-7Use of a Tandem and Ring Applicator Reference-CT to Improve Digitization in MR-Based Brachytherapy Planning
I Malajovich1*, B Teo2 , O Dolney3 , W Arscott4 , N Taunk5 , S Anamalayil6 , (1) University of Pennsylvania, Philadelphia, PA, (2) UNIVERSITY OF PENNSYLVANIA, Philadelphia, PA, (3) University Of Pennsylvia Hospital, Philadelphia, PA, (4) Univ. of Pennsylvania, Philadelphia, ,(5) University of Pennsylvania, Philadelphia, PA, (6) University of Pennsylvania, Philadelphia, PA
TH-A-301-1BEST IN PHYSICS (THERAPY): Deep-Learning Assisted Automatic Digitization of Interstitial Needles in High Dose-Rate Brachytherapy
H Jung*, C Shen , Y Gonzalez , X Jia , University of Texas Southwestern Medical Center, Dallas, TX
TH-A-301-4Delivering Intracavitary/Interstitial Brachytherapy Equivalent Dose Distributions with An Intracavitary-Only Helical Rotating Shield Brachytherapy Approach for Cervical Cancer Treatment
K Hopfensperger1*, Q Adams2, Y Kim2, X Wu3, W Xu3, K Patwardhan2, B Thammavong2, R Flynn2, (1) Department of Biomedical Engineering, University of Iowa, Iowa City, IA; (2) Department of Radiation Oncology, University of Iowa Hospitals and Clinics, Iowa City, IA; (3) Department of Electrical and Computer Engineering, University Of Iowa, College of Medicine, Iowa City, IA,
TH-A-301-5High Dose Rate Interstitial Spine Brachytherapy Using An Intraoperative Mobile CT Guided Surgical Navigation System
S Park1*, L Macyszyn2 , P Venkat1 , A Lee1 , A Chang1 , (1) Department of Radiation Oncology, University of California Los Angeles, Los Angeles, CA (2) Department of Neurosurgery, University of California Los Angeles, Los Angeles, CA
TU-C1030-GePD-F4-3Adaptive High-Dose Rate Brachytherapy in the Setting of Recurrent Nasal Carcinoma
J Pursley*, A Chan , T Nguyen , T Ruggieri , T Mauceri , Massachusetts General Hospital and Harvard Medical School, Boston, MA
TU-C1030-GePD-F4-4A Geometry-Based Pre-Planning System for Interstitial HDR Brachytherapy
Z Tian1,2*, J Tan1 , Y Gonzalez1 , K Albuquerque1 , X Jia1 (1) UT Southwestern Medical Center, Dallas, TX (2) Emory University, Atlanta, GA
WE-AB-301-0Cutting-Edge Brachytherapy
R Flynn1*, X Yang2*, C Deufel3*, J Zoberi4*, (1) University of Iowa Hospitals and Clinics, Iowa City, IA, (2) Emory University, Atlanta, GA, (3) Mayo Clinic, Rochester, MN, (4) Washington University School of Medicine, St. Louis, MO
WE-AB-301-1Re-inventing High-Dose-Rate Brachytherapy around Ytterbium-169
R Flynn1*, X Yang2*, C Deufel3*, J Zoberi4*, (1) University of Iowa Hospitals and Clinics, Iowa City, IA, (2) Emory University, Atlanta, GA, (3) Mayo Clinic, Rochester, MN, (4) Washington University School of Medicine, St. Louis, MO
WE-AB-301-2Image-Guided Catheter Placement for Prostate HDR Brachytherapy with Focal Tumor Boost using Machine Learning
R Flynn1*, X Yang2*, C Deufel3*, J Zoberi4*, (1) University of Iowa Hospitals and Clinics, Iowa City, IA, (2) Emory University, Atlanta, GA, (3) Mayo Clinic, Rochester, MN, (4) Washington University School of Medicine, St. Louis, MO
WE-AB-301-3Real-Time Electromagnetic Tracking in Clinical Brachytherapy Practice
R Flynn1*, X Yang2*, C Deufel3*, J Zoberi4*, (1) University of Iowa Hospitals and Clinics, Iowa City, IA, (2) Emory University, Atlanta, GA, (3) Mayo Clinic, Rochester, MN, (4) Washington University School of Medicine, St. Louis, MO
WE-AB-301-4Standardization and Automation of HDR Brachytherapy Plan QA with Application Programming Interface
R Flynn1*, X Yang2*, C Deufel3*, J Zoberi4*, (1) University of Iowa Hospitals and Clinics, Iowa City, IA, (2) Emory University, Atlanta, GA, (3) Mayo Clinic, Rochester, MN, (4) Washington University School of Medicine, St. Louis, MO
WE-C1030-GePD-F4-3Effect and Accuracy of Heterogeneity Corrected Dose Calculation in HDR Brachytherapy
E Schnell*, S Thompson , S Ahmad , T Herman , T De La Fuente Herman , University of Oklahoma Health Sciences Center, Oklahoma City, OK
WE-C1030-GePD-F4-4Development and Implementation of a Script-Based Brachytherapy Plan Checker
S Simiele*, X Chen , C Lee , B Rosen , J Mikell , J Moran , J Prisciandaro , Univ Michigan Medical Center, Ann Arbor, MI