MENU

Click here to

×

Are you sure ?

Yes, do it No, cancel

DISCLAIMER:
Entry of taxonomy/keywords during proffered abstract submission was optional.
Not all abstracts will appear in search results.

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # | show all

Keywords: film
MO-C930-GePD-F3-3Electron Backscatter From Internal Lead Shielding for Superficial Facial Electron Treatments
Y Xu1,3*, S Aldelaijan2,3 , I Buzurovic1,3 , M Czerminska1,3 , (1) Harvard Medical School, Boston, MA, (2) McGill University, Canada,(3) Brigham & Women's Hospital, Boston, MA
MO-C930-GePD-F4-2Measuring Dose Enhancement From Gold Nanoparticles in An 192Ir Setup
N Bassiri1*, T Gray2 , S David2 , D Patel2 , A Locker2 , K Rasmussen1 , N Papanikolaou1 , K Mayer2 , N Kirby1 , (1) UT Health at San Antonio (2)University of Texas at San Antonio
MO-I345-GePD-F1-2Validation of Monte Carlo Electron Dose Calculation in RayStation
K Yang*, H Chen , F Mourtada , Christiana Care Hospital, Newark, DE
MO-K-301-33D Validation of a Monte-Carlo Model of a Cyberknife System Dedicated to the Determination of Out-Of-Field Doses
J Colnot1*, V Barraux2 , C Loiseau2 , A Batalla2 , R Gschwind3 , C Huet1 , (1) Institut de Radioprotection et de Surete Nucleaire, Fontenay-aux-Roses, France, (2) CLCC Francois Baclesse, Caen, France, (3) Universite de Franche-Comte, LCE UMR CNRS, Montbeliard, France
PO-GePV-T-145An Improved Sensitometric Calibration Function for Radiochromic Film Dosimetry
T Ren1,2*, J Bourland1,2 , (1) Wake Forest School of Medicine, Winston-Salem, NC, (2) Wake Forest University, Winston-Salem, NC
PO-GePV-T-150A Method for Using a Global Dosimetric Leaf Gap and Transmission Factor for Beam Matched Linear Accelerators
D Dean*, M Price , K Homann , School of Medicine at Vanderbilt University, Nashville, TN
PO-GePV-T-158Evaluation of the Dosimetric Consistency of a Gafchromic Film Over Several Batches
M Aima1*, C Hammer2 , L DeWerd2 , W Culberson2 , (1) University of Texas M.D. Anderson Cancer Center, Houston, TX, (2) University of Wisconsin-Madison, Madison, WI
PO-GePV-T-171Improvement On the Dosimetric Performance of the Developed Lens-Type Dosimeter by the Optical Compensation
J Cho1,2*, J Son2 , O Kwon2 , J Kim2 , H An2 , C Choi2 , J Park2 , J Kim2 , (1) Yonsei University College of Medicine, Seoul, ,(2) Seoul National University Hospital, Seoul
PO-GePV-T-203Comparison of the Absorption Spectra of the EBT-XD and EBT3 Films Irradiated with Clinical Radiotherapy Beams
Y Leon*, D Mulrow , R Khan , A Darafsheh , Washington University School of Medicine, St Louis, MO
PO-GePV-T-259An Accurate Profile-Based Method for Starshot Analysis
R Rahimi Darabad, K Padgett, N Dogan, Y Yang*, University of Miami Miller School of Medicine, Miami, FL
PO-GePV-T-287Dose Perturbation of the Metallic Reservoir From a Novel Tissue Expander Used for Post Mastectomy Radiation Therapy
T Li*, B Hasson , C Geraghty , J Carroll , Anne Arundel Medical Center, Annapolis, MD
PO-GePV-T-311Gafchromic EBT-XD Film for Dose Profile Evaluation and Absolute Dose Measurement in High Dose Stereotactic Treatments
R Joseph , G Hatzinikolaou , S Kriminski*, Vassar Brothers Medical Center, Poughkeepsie, NY
PO-GePV-T-363Plan Optimization to Reduce Dose-Bridges in HyperARC Radiosurgery for Multiple Metastases and Dose Evaluation with EBT3 Film
H Park1*, J Park2 , J Lee3 , J Kim1 , M Kim1 , T Suh4 , Y Oh1 , M Chun1 , O Noh1 , (1) Department of Radiation Oncology, Ajou University School of Medicine, Suwon, South Korea (2) Department of Radiation Oncology, University of Florida, Gainesville, FL (3) Department of Radiation Oncology, Konkuk University Medical Center, Seoul, South Korea (4) Department of Biomedicine & Health Sciences, Research Institute of Biomedical Engineering, The Catholic Univerisy of Korea, College of Medicine, Seoul, South Korea
SU-E-221AB-3Experimental Evaluation of the Dosimetric Impact of Intrafraction Prostate Rotations Using Film Measurement with a 6 DoF Robotic Arm
K Shi1*, A Dipuglia2 , J Booth2 , S Alnaghy3 , A Kyme1 ,P Keall1 , D Nguyen1 , (1) University of Sydney, Sydney, NSW, (2) Royal North Shore Hospital, Marrickville, NSW, (3) University of Wollongong, Wollongong, NSW
SU-F-SAN1-4Development of An Aperture System for Ocular Treatments with a Gantry-Based Spot Scanning Proton Beam
S Hickling*, J Kruse , S Corner , J Pulido , A Deisher , Mayo Clinic, Rochester, MN
SU-I330-GePD-F4-3On the Spatial Accuracy of Single Isocenter Multiple Brain Metastases SRS with BrainLab Elements
D Saenz*, J McCulloch , K Rasmussen , N Kirby , P Myers , S Stathakis , N Papanikolaou , University of Texas HSC SA, San Antonio, TX
SU-I430-GePD-F4-6Dosimetric Effects of Varying Dwell Position Step Size in Mesh HDR Brachytherapy for Skin Lesions
J Cates*, Z Kang, S Kucuker Dogan, H Zhang, Northwestern Memorial Hospital, Chicago, IL
SU-L-SAN1-2Clinical Feasibility of a Novel Reusable Radiochromic 2D Sheet Dosimeter
C Collins1*, S Yoon1 , J Kodra1 , R Coakley2 , E Subashi1 , K Sidhu1 , J Adamovics2 , M Oldham1 , (1) Duke University, Durham, NC, (2) Rider University, Lawrence, NJ
TH-D-304-2"Is There a Threshold Limit for Dosimetric Impact Due to Breathing Motion During Lung VMAT Delivery"? -Experimental Measurement of Dose Measured in Moving Lung Tumors
R Varadhan1*, S Way2 , M Bedoya3 , N Dickson4 , N Anderson5 , (1) Minneapolis Radiation Oncology, Fridley, MN, (2) Minneapolis Radiation Oncology, Robbinsdale, MN, (3) University of Minnesota, Minneapolis, MN, (4) MINNEAPOLIS RADIATION ONCOLOGY, Edina, MN, (5) Minneapolis Radiation Oncology, New Richmond, WI
TU-C1000-GePD-F4-1Triple-Channel Dosimetry with The Channel Weighted Perturbation Method
T Ren1,2*, J. Daniel Bourland1,2 , (1) Wake Forest University, Winston-Salem, NC, (2) Wake Forest School of Medicine, Winston-Salem, NC
TU-C1000-GePD-F7-6Systematic Evaluation of the Spectral Response of EBT3 Radiochromic Films to Proton Therapy Beams
A Darafsheh1*, D Mulrow1, Y Leon1, T Zhao1, S Mossahebi2, A Kassaee3, R Khan1, (1) Washington University School of Medicine, St Louis, MO, (2) University of Maryland School of Medicine, Baltimore, MD, (3) University of Pennsylvania, Philadelphia, PA
TU-C1030-GePD-F7-3Dosimetric Evaluation of Shielding Materials for Critical Organ Protection in 50 KV Intrabeam Intraoperative Radiation Therapy (IORT)
S Trichter*, F Kulidzhanov , JK DeWyngaert , New York-Presbyterian Hospital, Weill Cornell Medical Center, New York, NY
TU-C930-GePD-F4-3Time Evolution of the Response of Irradiated EBT-XD Radiochromic Films
D Mulrow*1,2, Y Leon1, A Darafsheh1, R Khan1, (1) Washington University School of Medicine, St Louis, MO, (2) Washington University in St. Louis, St. Louis, MO
TU-HI-SAN4-11In-Vivo Skin Dosimetry Using the Novel CARA Breast Support for Supine Adjuvant Whole Breast Radiotherapy
E Carpentier1,2*, E Facchin2 , J Yanchuk3 , B Gill2 , C Duzenli1,2 , (1) University of British Columbia, Vancouver, BC, Canada, (2) BC Cancer, Vancouver, BC, Canada, (3) BC Cancer, Kelowna, BC, Canada
TU-J345-GePD-F4-2Evaluation of Uncertainties in EBT3 Film Dosimetry On An Orthovoltage Small Animal Irradiator
Q Chen*, D Carlton , T Howard , T Izumi , J Molloy , University of Kentucky, Lexington, KY
WE-C1000-GePD-F4-5Effect of Magnetic Field On the Spectral Response of EBT3 Radiochromic Films in MRIgRT
A Darafsheh, D Mulrow*, B Maraghechi, F Reynoso, R Khan, Washington University School of Medicine, St Louis, MO