DISCLAIMER:
Entry of taxonomy/keywords during proffered abstract submission was optional.
Not all abstracts will appear in search results.
MO-C930-GePD-F3-1 | Investigation of Effect of Filter On the Total Skin Irradiation Using Monte Carlo Simulation W Tseng*, R Li , Q Wu , Duke University Medical Center, Durham, NC |
MO-C930-GePD-F3-3 | Electron Backscatter From Internal Lead Shielding for Superficial Facial Electron Treatments Y Xu1,3*, S Aldelaijan2,3 , I Buzurovic1,3 , M Czerminska1,3 , (1) Harvard Medical School, Boston, MA, (2) McGill University, Canada,(3) Brigham & Women's Hospital, Boston, MA |
MO-C930-GePD-F3-4 | Evaluation of a Modified Pencil Beam Algorithm Dose Calculation in the Presence of Intensity Modulators for Intensity Modulated Bolus Electron Beam Conformal Therapy E Hilliard1,2*, R Carver2 , K Hogstrom3 , K Erhart4 , (1) Medical University of South Carolina, Charleston, SC, (2) Mary Bird Perkins Cancer Center, Baton Rouge, LA, (3) Mary Bird Perkins Cancer Center, Baton Rouge, LA, (4) .decimal LLC, Sanford, FL |
MO-C930-GePD-F3-5 | Whole Body Surface Cherenkov Distribution Analysis in Total Skin Electron Therapy Using Computer Animation Methods T Miao1*, H Petroccia2 , Y Xie3 , J Mahoney1 , P Bruza1 , M Jermyn4 , B Pogue1 , D Gladstone5 , T Zhu2, B Williams5 , (1) Dartmouth College, Hanover, NH, (2) University of Pennsylvania, Philadelphia, PA, (3) Massachusetts General Hospital, Boston, MA, (4) DoseOptics LLC, Lebanon, NH, (5) Dartmouth-Hitchcock Med. Ctr., Lebanon, NH |
MO-I345-GePD-F1-4 | Validation of Total Skin Irradiation Using Two Monte Carlo Systems W Tseng1*, R Li2 , Q Wu3 , D Sawkey4 , (1) Duke University Medical Center, Durham, NC, (2) Duke University Medical Center, Durham, NC, (3) Duke University Medical Center, Durham, NC, (4) Varian Medical Systems, Palo Alto, CA |
PO-GePV-P-37 | Characterization of a Non-Clinical FLASH Beam R Sadagopan6*, J Pollard-Larkin1 , R Tailor2 , P Balter3 , M Gillin4 , J Symons5 , (1) MD Anderson Cancer Center, Houston, TX, (2) UT MD Anderson Cancer Center, Houston, TX, (3) UT MD Anderson Cancer Center, Houston, TX, (4) MD Anderson Cancer Ctr., Houston, TX, (5) MD Anderson UTHealth Graduate School, Houston, TX, (6) MD Anderson Cancer Center, Houston, TX |
PO-GePV-T-33 | An Elegant Solution to Satisfy TG 142 Recommendations for Annual Electrons Output and Off-Axis Factor Constancy Versus Gantry Angle Variation E Galhardo*, G Narayanasamy , G Deshazer , S Morrill , University of Arkansas for Medical Sciences, Little Rock, AR |
PO-GePV-T-34 | Dosimetric Evaluation of Electron Beam Doses at Various Interfaces K Bales1*, R George1 , M Naessig1 , K Fischer1 , N Papanikolaou1 , N Kirby1 , P Myers1 , D Saenz1 , K Rasmussen1 , S Stathakis1 , (1) University of Texas HSC SA, San Antonio, TX |
PO-GePV-T-35 | New Acceptance Criteria for Evaluating Electron Beam Percentage Depth Dose Using OSLD Remote Audits P Alvarez*, P Taylor , J Lowenstein , A Molineu , S Kry , D Followill , UT MD Anderson Cancer Center, Houston, TX |
PO-GePV-T-37 | Preliminary Study for Improvement of the Stochastic Noise in the Electron Monte Carlo (eMC) Dose Distribution Using Deep Learning D Shin*, S Kang , K Kim , T Suh , The Catholic University of Korea, College of Medicine, Seoul, Republic of Korea |
PO-GePV-T-38 | The Effects of High-Z Heterogeneities On the Dose Deposition of Energetic Electron Beam Therapy I Ali1*, N Alsbou2 , S Ahmad1 , (1) University of Oklahoma Health Sciences, Oklahoma City, OK, (2) Department of Engineering and Physics, University of Central Oklahoma, Edmond, OK, |
PO-GePV-T-39 | Feasibility of 3D Printed High-Metal Content Copper Filament for Electron Cutouts D Dunkerley1*, M Daniels2 ,A Shepard1 , K Schaefer1 , (1) University of Wisconsin-Madison, Madison, WI, (2) The Virtual Foundry, Stoughton, WI |
SU-L-SAN1-1 | Characterization of a Novel Scintillator Imaging-Based Surface Dosimeter I Tendler1*, P Bruza1 , M Jermyn2 , X Cao1 , B Williams3,4 , L Jarvis3,4 , B Pogue1,2,3 , D Gladstone1,3,4 , (1) Thayer School of Engineering, Dartmouth College, Hanover, NH, (2) DoseOptics LLC, Lebanon, NH, (3) Dept. of Medicine, Geisel School of Medicine, Dartmouth College, Hanover, NH (4) Norris Cotton Cancer Center, Dartmouth-Hitchcock Med. Ctr., Lebanon, NH, (5) |
TU-C930-GePD-F3-1 | Validation of a Laying Down Technique for Total Skin Irradiation Using Monte Carlo R Li*, Q Wu , Duke University, Durham, NC |
TU-C930-GePD-F3-2 | CT-Less Electron Radiotherapy with a Consumer Stereo Depth Camera L Skinner1*, Y Wang1, A Yu1, (1) Stanford University Cancer Center, Stanford, CA. |
WE-C1000-GePD-F1-2 | Dosimetric Comparison of Several Radiotherapy Techniques in the Treatment of Scalp Cancer D Schulze*, H Zhang , Northwestern Memorial Hospital, Chicago, IL |
WE-J-301-3 | Accurate and Instant Prediction of Electron Cutout Factor by An Efficient Residual Neural Network (ResNet) Model C He1 , L Lu2 , T Zhu3 , D Nie4 , S Chang5 , D Shen6 , J Lian7*, (1) Duke University, Durham, ,(2) The University of North Carolina at Chapel Hill, Chapel Hill, NC, (3) Univ of North Carolina at Chapel Hill, Chapel Hill, NC, (4) UNC Chapel Hill, Chapel Hill, ,(5) UNC School of Medicine, Chapel Hill, NC, (6) University of North Carolina at Chapel Hill, Chapel Hill, ,(7) Univ North Carolina, Chapel Hill, NC |
WE-J-301-9 | Monte Carlo Modeling and Validation for MLC Based Electron Apertures M Kaluarachchi*, M Schwer , Z Saleh , E Klein , Rhode Island Hospital / Warren Alpert Medical School of Brown, Providence, RI |