MO-E115-GePD-F4-1 | A Software Tool to Harvest and Analyze MLC Log Files of the Elekta VersaHD Linear Accelerator P Myers*, C Kabat , D Saenz , K Rasmussen , N Kirby , N Papanikolaou , S Stathakis , University of Texas HSC SA, San Antonio, TX |
MO-I345-GePD-F2-4 | TG263-Net: A Deep Learning Model for Organs-At-Risk Nomenclature Standardization D Rhee1*, C Nguyen2 , T Netherton3 , C Owens4 , L Court5 , C Cardenas6 , (1) MD Anderson Cancer Center, Houston, TX, (2) MD Anderson Cancer Center, Houston, TX, (3) MD Anderson Cancer Center, Houston, TX, (4) University of Texas MD Anderson Cancer Center, Houston, TX, (5) UT MD Anderson Cancer Center, Houston, TX, (6) University of Texas MD Anderson Cancer Center, Houston, TX |
PO-GePV-T-129 | A Comprehensive Database for the Physics On-Call System M Mohamed1*, J Chow2 , (1) Ryerson University, Toronto, ON, (2) Princess Margaret Cancer Centre, Toronto, ON |
PO-GePV-T-130 | Physics On-Call Scheduling Using Monte Carlo Simulation X Bauza1*, J Chow2 , (1) Ryerson University, Toronto, ON, (2) Princess Margaret Cancer Centre, Toronto, ON |
SU-I400-GePD-F5-2 | From Data Extraction to Abstraction: Lessons Learned in Acquiring and Interpreting High Quality Clinical Data M Schmidt*, D Caruthers , F Reynoso , W Bosch , C Robinson , J Kavanaugh , J Hilliard , N Knutson , S Mutic , G Hugo , Washington University School of Medicine in St. Louis, Saint Louis, MO |
SU-I430-GePD-F9-5 | Step-Wise Solution to Evaluate CT Radiomic Feature Variability Due to Correlated Noise Texture M Shafiq ul Hassan1*, F Guo1 , H Chen1 , G Zhang2 , E Moros2 , Z Chen1 , (1) Yale New Haven Hospital, New Haven, CT, (2) Moffitt Cancer Center, Tampa, FL, |
SU-I430-GePD-F9-6 | Subset of Reproducible Radiomic Features as a Function of Multiple CT Imaging Parameters M Shafiq ul Hassan1*, F Guo1 , H Chen3 , G Zhang4 , E Moros5 , Z Chen6 , (1) Yale New Haven Hospital, New Haven, CT, (2) Yale New Haven Hospital, New Haven, CT, (3) Yale New Haven Hospital, New Haven, CT, (4) H. Lee Moffitt Cancer Center, Tampa, FL, (5) H. Lee Moffitt Cancer Center, Tampa, FL, (6) Yale Univ. School of Medicine & YNHH, New Haven, CT |
SU-L-SAN1-7 | PodPhantom: A Robotic Prototype Dosimetric Data Collection System for GammaPod D Parsons*, T Chiu , Y Zhang , W Lu , S Jiang , X Gu , UT Southwestern Medical Center, Dallas, TX |
SU-L-SAN4-8 | An Open-Source Approach to Automating Data-Analysis for Multiple Linac Commissioning K Hasse*, A Perez-Andujar , Y Natsuaki , A Witztum , B Ziemer , S St. James , University of California San Francisco, San Francisco, CA |
TH-BC-225BCD-1 | Evaluation of a New Highly Flexible, Low Profile RF Coil for MR Simulation of the Head and Neck K McGee1*, P Rossmann1 , R Stormont2 , S Lindsay2 , J Huston1 , N Campeau1 , K Welker1 , J Christopherson1 , R Molthen2 , V Goruganti3 , (1) Mayo Clinic, Rochester, MN, (2) GE Healthcare, Waukesha, WI, (3) NeoCoil Inc, Pewaukee, WI |
TU-C1030-GePD-F7-4 | Developing An Automated Method for Pre-Treatment Data Transfer Checks J Rembish1*, P Myers1 , K Rasmussen1 , N Kirby1 , D Saenz1 , P Mavroidis2 , N Papanikolaou1 , C Kabat1 , N Bice1 , S Stathakis1 , (1) UT Health San Antonio, San Antonio, TX, (2) Univ North Carolina, Chapel Hill, NC |
WE-AB-221AB-9 | Low Dose Ultra-High Resolution Sinus Imaging Using Photon-Counting Detector CT with Tin Filter K Rajendran*, W Zhou , S Tao , B Voss , M Bruesewitz , J Weaver , D DeLone , J Fletcher , C McCollough , S Leng , Mayo Clinic, Rochester, MN |
WE-C1030-GePD-F9-5 | Can CT Image Truncation Cause False Dose Alerts in a Dose Management System? N Fitousi1*, A Dedulle2 , J Jacobs3 , H Bosmans4 , (1) Qaelum NV, Leuven, ,(2) Qaelum NV, Leuven, ,(3) Qaelum NV, Leuven, ,(4) University Hospitals Leuven, Leuven, |