MO-C930-GePD-F5-6 | The Accuracy of Different Clinical Dual-Energy CT Systems for Proton Therapy Applications E Baer1*, A Warry2, V Rompokos2, G Royle1, A Poynter2, (1) University College London, London (2) University College London Hospital, London |
MO-E115-GePD-F7-4 | Characterization of Common Dental Hardware Materials for Head-And-Neck Proton Therapy Y Hu1*, R Greenland2 , D Mundy1 , (1)Department of Radiation Oncology, Division of Medical Physics, Mayo Clinic, Rochester, MN, (2) Department of Advanced Prosthodontics, Mayo Clinic, Rochester, MN |
MO-K-SAN1-0 | Advances in Proton and Particle Therapy K Parodi1*, A Lalonde2*, X Ding3*, (1) Ludwig-Maximilians-University Munchen, Garching B. Munich, Germany, (2) Montreal, QC, (3) William Beaumont Hospital, Bloomfield Hills, MI |
MO-K-SAN1-1 | Advances in ion imaging and range verification K Parodi1*, A Lalonde2*, X Ding3*, (1) Ludwig-Maximilians-University Munchen, Garching B. Munich, Germany, (2) Montreal, QC, (3) William Beaumont Hospital, Bloomfield Hills, MI |
MO-K-SAN1-2 | Multi-energy CT for dose calculation in particle therapy K Parodi1*, A Lalonde2*, X Ding3*, (1) Ludwig-Maximilians-University Munchen, Garching B. Munich, Germany, (2) Montreal, QC, (3) William Beaumont Hospital, Bloomfield Hills, MI |
MO-K-SAN1-3 | Spot-scanning Proton Arc therapy: from a concept to reality. K Parodi1*, A Lalonde2*, X Ding3*, (1) Ludwig-Maximilians-University Munchen, Garching B. Munich, Germany, (2) Montreal, QC, (3) William Beaumont Hospital, Bloomfield Hills, MI |
PO-GePV-T-115 | Clinical Workflow to Evaluate and Incorporate a High Density Implant Into Pencil Beam Scanning Proton Therapy Planning W Zheng*, X Li , D Yan , D Moore , K Les , C Stevens , P Kabolizadeh , X Ding , William Beaumont Hospital, Royal Oak, MI |
WE-C1030-GePD-F7-4 | A Deep Learning Approach for Dual-Energy CT Based Proton Stopping-Power-Ratio Estimation H Lee*, X Duan , X Jia , M Yang , UT Southwestern Medical Center, Dallas, TX |
WE-HI-SAN2-10 | Method for Fluence Field Optimization to Achieve Non-Convex Image Noise Prescriptions with Fluence-Modulated Proton CT J Dickmann*1, P Wesp1, S Rit2, M Pankuch3, R P Johnson4, V Bashkirov5, R W Schulte5, K Parodi1, G Dedes1, G Landry1,6, (1) Ludwig-Maximilians-Universitaet Muenchen, Munich, Germany, (2) Universite de Lyon, Lyon, France, (3) Northwestern Medicine Chicago Proton Center, Warrenville, IL, (4) U.C. Santa Cruz, Santa Cruz, CA, (5) Loma Linda University, Loma Linda, CA, (6) University Hospital, LMU Munich, Munich, Germany |