Keywords: Small Fields
MO-AB-SAN1-10Small Field Dosimetry: Detector Dependency On Output Factor and Off-Axis-Ratio Measurements for a Novel Radiosurgery System
D Pinnaduwage1*, S Srivastava1 , X Yan1 , S Jani1 , C Jenkins2 , G Weidlich2 , M Bodduluri2 , S Sorensen1 , (1) Barrow Neurological Institute (BNI) St. Joseph's Hospital & Medical Center, Phoenix, AZ, (2) Zap Surgical Systems, Inc., San Carlos, CA
MO-I345-GePD-F3-1A Monte Carlo-Based Assessment of Scatter Contribution in Jaws Vs. MLCs Defined Small Fields for Varian Edge Linear Accelerator
K Xie*, E Salari , D Shvydka , A Qureshi , N Sperling , J Kunz , E Parsai , University of Toledo Medical Center, Toledo, OH
PO-GePV-T-320Validation of Small Field Dosimetry for Stereotactic SRS Cones and Effect of Angular Dependence with Respect to the Scanning System
S Kucuker Dogan*, M Gopalakrishnan , Northwestern Memorial Hospital, Chicago, IL
PO-GePV-T-321Evaluation of a New Plastic Scintillation Detector for Stereotactic Radiosurgery Applications
D Jacqmin*, J Miller , Z Labby , A Shepard , B Barraclough , University of Wisconsin, Madison, WI
PO-GePV-T-326Evaluation of Arccheck Towards Small Field Plan QA Measurement Based On Output Factor Results
Y Wang*, X Wu , Credit Valley Hospital/Trillium Health Partners, Mississauga, ON
PO-GePV-T-354Impact of Effective Target Spot Size and Beam Data Field Size Range On the Agreement Between Measured Small Field PDDs and Profiles and Those Predicted by Acuros Beam Model of Version 13
Y Wang*, X Wu , T Mutanga , G Zeng , M Nielsen , Trillium Health Partners/the Credit Valley Hospita, Mississauga, ON
PO-GePV-T-368Validating the Brainlab Cranial SRS Element for the Versa HD
C Knill*, R Sandhu , R Halford , Z Seymour , Beaumont Hospital, Dearborn, MI
PO-GePV-T-389Gel Dosimetry to Commission a Research Linear Accelerator for Small Field Animal Irradiation Studies
N Ba Sunbul*, I Oraiqat , B Rosen , C Miller , M Matuszak , S Clarke , S Pozzi , J Moran , I El Naqa , Univ of Michigan , Ann Arbor, MI
SU-K-SAN1-4On the Discrepancy of Experimental and Monte-Carlo Simulated Dose Response of the MicroDiamond Detector: The Role of Charge Imbalance in Structural Components
HK Looe1*, D Poppinga2 , R Kranzer2 , I Buesing1 , T Tekin1 , AB Ulrichs1 , B Delfs1 , D Vogt2 , J Wuerfel2 , B Poppe1 , (1) University Clinic for Medical Radiation Physics, Medical Campus Pius Hospital, Carl von Ossietzky University, Oldenburg, Germany (2) PTW Freiburg, Germany
SU-K-SAN1-7Characterization of Small Field Output Factors for a Medical Linear Accelerator with a Dual-Layer Stacked and Staggered MLC System
P Irmen*, T Li , University of Pennsylvania, Philadelphia, PA
TH-BC-301-5Development and Implementation of a Small Field Calibration Procedure for a Novel Stereotactic Radiosurgery Device Utilizing TG-21 & IAEA TRS 483
S Becker*, E Nichols , B Yi , Univ. of Maryland School Of Medicine, Baltimore, MD
TU-J345-GePD-F3-4Use and Validation of IAEA Correction Factors for Small Field Dosimetry Commissioning: A Multi-Institution Study
V Yu1*, C Lee1 , S Tenn1 , D O'Connell1 , L Weinstein2 , M Skinner2 , C McGuinness2 , D Saenz3 , N Papanikolaou3 , N Agazaryan1 , (1) UCLA School of Medicine, Los Angeles, CA, (2) Kaiser Permanente, South San Francisco, South San Francisco, CA, (3) University of Texas HSC SA, San Antonio, TX
WE-C1000-GePD-F4-2Comparison of W1 and W2 Plastic Scintillation Detectors with Small Field Output Factors
J McKay*, S Petro , M Axente , B Velasco , C Liu , Erlanger Health System, Chattanooga, TN