DISCLAIMER:
Entry of taxonomy/keywords during proffered abstract submission was optional.
Not all abstracts will appear in search results.
MO-K-301-6 | GPU-Accelerated Monte Carlo Code FRED for Clinical Application in Proton Therapy A Rucinski1*, J Baran2 , G Battistoni3 , M Durante4 , J Gajewski5 , M Garbacz6 , R Kopec7 , N Krah8 , G Mierzwinska9 , N Mojzeszek10 , V Patera11 , M Pawlik-Niedzwiecka12 , E Pluta13 , I Rinaldi14, E Scifoni15 , A Skrzypek16 , F Tommasino17 , A Schiavi18 , (1) Institute of Nuclear Physics PAN, Krakow, Poland, (2) Institute of Nuclear Physics PAN, Krakow, Poland, (3) INFN, Milan, Italy, (4) GSI Helmholtzzentrum fur Schwerionenforschung, Technische Universitat Darmstadt, Germany, (5) Institute of Nuclear Physics PAN, Krakow, Poland, (6) Institute of Nuclear Physics PAN, Krakow, Poland, (7) Institute of Nuclear Physics PAN, Krakow, Poland, (8) University Lyon, CNRS, CREATIS UMR 5220, Centre Lyon Berard, Lyon, France, (9) Institute of Nuclear Physics PAN, Krakow, Poland, (10) Institute of Nuclear Physics PAN, Krakow, Poland, (11) Sapienza University of Rome, Rome, Italy, (12) Institute of Nuclear Physics PAN, Krakow, Poland, (13) M. Sklodowska-Curie Institute OC, Krakow, Poland, (14) ZonPCT/Maastro clinic, Maastricht, Netherlands, (15) TIFPA, Trento, Italy, (16) Institute of Nuclear Physics PAN, Krakow, Poland, (17) TIFPA, Trento, Italy, (18) Sapienza University of Rome, Italy |
PO-GePV-P-42 | Examining the Influence of Variable RBE Models On Passive Scattering Proton Therapy Esophageal Cancer Patients by Means of the Fast Dose Calculator at The University of Texas MD Anderson Cancer Center A Adair1*, Q Wang1 , P Yepes1 , S Lin2 , M Aldehaim2 , U Titt2 , D Mirkovic2 , R Mohan2 , (1) Rice University & University of Texas MD Anderson Cancer Center, Houston, TX, (2) University of Texas MD Anderson Cancer Center, Houston, TX, |
PO-GePV-T-59 | Tumor Control Probability for Non-Small Cell Lung Cancer Treated with Proton Therapy: Constant Versus Variable RBE-Weighted Dose C Peeler*, U Titt , R Mohan , Z Liao , D Mirkovic , U.T. M.D. Anderson Cancer Center, Houston, TX |
TU-AB-SAN1-5 | First Report On Methodology Development and Validation of LET Computed in a Monte Carlo Dose Engine of a Commercial Treatment Planning System D Wagenaar1*, T Tran2 , A Meijers1 , D Bolst2 , B James2 , M Povoli3 , A Kok3 , E Traneus4 , M van Goethem1 , J Langendijk1 , A Rosenfeld2 , S Both1 , (1) University of Groningen, University Medical Center Groningen, Groningen, the Netherlands (2) University of Wollongong, Wollongong, Australia (3) SINTEF, Oslo, Norway (4) RAYSEARCH LABORATORIES AB, Stockholm, Sweden |
TU-AB-SAN1-7 | Implementation and Validation of a Microdosimetric Extension for the TOPAS Monte Carlo Toolkit H Zhu1,2,3*, Y Chen1,2,3 , W Sung1,4 , A McNamara1,4 , T Tran5 , L Burigo6 , A Rosenfeld5 , J Li2,3 , B Faddegon7 , J Schuemann1,4 , H Paganetti1,4 (1) Department of Radiation Oncology, Massachusetts General Hospital, Boston, MA, (2)Department of Engineering Physics, Tsinghua University, Beijing 100084, P.R. China, (3)Key Laboratory of Particle & Radiation Imaging (Tsinghua University), Ministry of Education, Beijing 100084, P.R. China, (4) Harvard Medical School, Boston, MA 02114, USA, (5) Centre for Medical Radiation Physics, University of Wollongong, Australia, (6) German Cancer Research Center-DKFZ, Im Neuenheimer Feld 280, D-69120 Heidelberg, Germany, (7) Department of Radiation Oncology, University of California San Francisco, CA 94143, USA |
TU-AB-SAN1-9 | Linear Energy Transfer Incorporated Spot Scanning Proton Arc Therapy (SPArc) Optimization X Li1*, X Ding1 , G Liu1 , G Janssens2 , K Souris3 , A Barragan Montero3 , D Yan1 , C Stevens1 , P Kabolizadeh1 , (1)Beaumont Health System, Royal Oak, MI, (2) Ion Beam Applications SA, Louvain-la-neuve, Belgium, (3) Universite Catholique de Louvain, Louvain-la-neuve, Belgium |
WE-C1030-GePD-F1-5 | Treatment Planning Strategies to Mitigate the Range and RBE Uncertainties in Proton Therapy for Targets in the Brain N Sahoo*, A Gautam , F Poenisch , T Williamson , X Zhang , Y Li , H Li , R Wu , M Gillin , D Grosshans , X Zhu , UT MD Anderson Cancer Center, Houston, TX |
WE-FG-301-2 | Assessing DNA Damage of Proton Vs. Photon Beams Using Plasmid DNA B Behnke1 , A Giebeler2 , G Mardirossian3 , M Tambasco4 , M Tambasco5*, (1) San Diego State Univ, San Diego, California, (2)California Protons Cancer Therapy Center, San Diego, CA, (3) Genesis Healthcare Partners, Carlsbad, CA, (4) San Diego State Univ, San Diego, CA, (5) San Diego State Univ, San Diego, CA |