MENU

Click here to

×

Are you sure ?

Yes, do it No, cancel

DISCLAIMER:
Entry of taxonomy/keywords during proffered abstract submission was optional.
Not all abstracts will appear in search results.

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # | show all

Keywords: Organ Motion
MO-AB-SAN1-7Validation of Radixact Motion Tracking and Compensation for 3D Respiratory Motion
W Ferris1*, M Kissick2, W Culberson1, J Smilowitz1,3, (1) Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison (2) Accuray Inc., Madison, WI 53717 (3) Department of Human Oncology, School of Medicine and Public Health, University of Wisconsin - Madison
MO-K-303-3Continuous Long-Term Imaging with Robotic 4D Ultrasound for Motion Compensation in Radiotherapy and Beyond
S Ipsen*, I Kuhlemann , A Schweikard , F Ernst , Institute for Robotics and Cognitive Systems, University of Luebeck, Luebeck, Germany
MO-K-303-6Enabling MRI-Guided Radiation Therapy of the Pancreas with MRI Compatible Ultrasound Sensors
J Kwon1,2*, C.-C. Cheng3, F Preiswerk3, B Madore3, S Shimizu2, H Shirato2, J Bredfeldt1, (1) Brigham and Women's Hospital, Dana-Farber Cancer Institute and Harvard Medical School, Boston, MA, (2) Hokkaido University, Sapporo, Japan, (3) Brigham and Women's Hospital, Boston, MA
PO-GePV-T-100A Dynamically Adaptable IMPT Planning and Delivery Technique for Prostate with Pelvic Nodal to Mitigate Dosimetric Impact of Prostate Interfraction Motion
Z Su*, R Henderson , B Hoppe , R Nichols , C Bryant , W Mendenhall , N Mendenhall , Z Li , University of Florida, Gainesville, FL
PO-GePV-T-136Definition of Interatrial Septum and Interventricular Septum Margin and Internal Organs at Risk Volume (IRVs) Based On ECG-Gated 4DCT
Q Li*, G Gong , Y Yin , Shandong Cancer Hospital Affiliated to Shandong University, Jinan, China
SU-I430-GePD-F5-1Electromagnetic-Guided Gating in Radiation Treatment of Lung Cancers: Real-Time Internal Motion Monitoring and Couch Correction
L Zhang*, M Lovelock , E Yorke , A Rimner , P Zhang , G Mageras , Memorial Sloan Kettering Cancer Center, New York, NY
SU-L-SAN2-3Cumulative Dose Modeling for Organ Motion Management in MRI-Guided Radiation Therapy
A Mirzapour1*, T Mazur2 , H Li2 , E Salari1 , G Sharp3 , (1) Wichita State University, Wichita, KS, (2) Washington University School of Medicine, St Louis, MO, (3) Massachusetts General Hospital, Boston, MA
SU-L-SAN2-7On the Development of Real-Time Motion Tracking Using 2D-To-3D MRI Registration for MR-Linac
T Keiper1*, A Tai2 , L Wang3 , X Chen4 , E Paulson5 , F Lathuiliere6 , D Cooper7 , M Lachaine8 , X Li9 , (1) Medical College of Wisconsin, Milwaukee, WI, (2) Medical College of Wisconsin, Milwaukee, WI, (3) Medical College of Wisconsin, Milwaukee, WI, (4) Medical College of Wisconsin, Milwaukee, WI, (5) Medical College of Wisconsin, Milwaukee, WI, (6) Elekta, Montreal, QC,(7) Elekta, Montreal, QC,(8) Elekta, Montreal, QC, (9) Medical College of Wisconsin, Milwaukee, WI
SU-L-SAN4-7Does Motion Interplay Affect Tumor Coverage in IMRT and VMAT Lung SBRT? A 4D Dosimetry Study Using Dynamic Virtual Patient Model
T Ma*, B Guo , S Balik , P Qi , A Magnelli , K Stephans , G Videtic , T Zhuang , Cleveland Clinic Foundation, Cleveland, OH
TH-A-SAN2-5Can a Statistical Model of Daily Abdominal Variations in a Cohort of Pancreatic Cancer Patients Be Used to Select Who May Benefit From Plan Adaptation in SBRT?
A Magallon-Baro , P Granton*, M Milder , M Loi , A Zolnay , J Nuyttens , M Hoogeman , Erasmus MC Cancer Institute, University Medical Center Rotterdam, Department of Radiotherapy, The Netherlands
TH-BC-303-7A Potential Approach of Real-Time Motion Tracking of MR-Guided-Radiotherapy Using Ultra-Fast Volumetric 4D-MRI Generated VOI Positional Probability Distribution
O Wong*, J Yuan , Y Zhou , S Yu , K Cheung , Hong Kong Sanatorium & HospitalHong Kong
TU-C1030-GePD-F5-2Development of a Centralized Motion Prediction Model for Motion Management in Radiation Therapy
J Kim*, A Tai , X Li , H Zhong , Medical College of Wisconsin, Milwaukee, WI
TU-C1030-GePD-F9-6What Image Features Are Good for Correlation-Based Tracking Algorithms Used for Soft Tissue Monitoring in X-Ray Imaging
A Jeung*, L Zhu , H Mostafavi , J van Heteren , Varian Medical Systems, Palo Alto, CA
WE-HI-301-1BEST IN PHYSICS (THERAPY): Accounting for Respiration-Induced Motion of Peripheral Airways in Virtual Bronchoscopy-Guided Lung Stereotactic Ablative Radiotherapy Planning
E Vicente1*, A Modiri1 , K Yu2 , H Wibowo2 , Y Yan3 , R Timmerman3 , A Sawant1 , (1) University of Maryland, School of Medicine, Baltimore, MD, (2) Broncus Medical, Inc., San Jose, CA, (3) UT Southwestern Medical Center, Dallas, TX.
WE-HI-301-2BEST IN PHYSICS (THERAPY): Geometric Risk Index: Quantifying Plan Robustness with Respect to Geometric Uncertainty and DVH Objectives
J Neylon*, R Li , S Glaser , A Amini , J Wong , A Liu , City Of Hope, Duarte, CA
WE-HI-303-7Detection of Dosimetrically Relevant Anatomical Changes Near the Pancreas with MRI Compatible Ultrasound Sensors
J Kwon1,2, D Brivio1, J Mancias1, C.-C. Cheng3, F Preiswerk3, B Madore3, J Bredfeldt1*, (1) Brigham and Women's Hospital, Dana-Farber Cancer Institute and Harvard Medical School, Boston, MA, (2) Hokkaido University, Sapporo, Japan, (3) Brigham and Women's Hospital, Boston, MA