MENU

Click here to

×

Are you sure ?

Yes, do it No, cancel

Using Artificial Intelligence to Auto-Delineate Patient-Specific Head-And-Neck Clinical Target Volumes Within a Fully-Automated Treatment Planning System

C Cardenas1*, M Aristophanous2 , J Yang1 , L Zhang1 , R McCarroll3 , K Kisling1 , D Rhee1 , S Ng1 , A Rao4 , C Fuller1 , A Mohamed1 , A Garden1 , L Court1 , (1) MD Anderson Cancer Center, Houston, Texas, (2) The University of Chicago, Chicago, IL, (3) University of Maryland Medical Center, Baltimore, MD, (4) The University of Michigan, Ann Arbor, MI,

Presentations

(Saturday, 3/30/2019) 10:30 AM - 12:30 PM

Room: Osceola Ballroom C

Purpose: To use artificial intelligence to automate clinical target volume (CTV) delineation for oropharyngeal cancer patients and, therefore, reduce inter-physician variability which is the largest source of uncertainty in head-and-neck radiotherapy. This auto-delineation would address a rate-limiting step in fully-automated treatment planning.

Methods: To establish a baseline, we assessed inter-physician CTV delineation variability from a team of sub-specialized head-and-neck radiation oncologists. Then, we developed models to auto-delineate (1) high-risk CTVs using a feedforward network that uses tumor and organs-at-risk information, and (2) low-risk CTVs using a 3D convolutional neural network that uses the CT image and GTV. Each algorithm’s auto-delineations were compared to clinically-used CTVs using overlap/distance metrics. These delineations were then used in our automated treatment planning system to evaluate the impact of CTV delineation on dosimetric distributions.

Results: The measured inter-physician variability resulted in a median Dice Similarity Coefficient (DSC) of 0.75, translating to better agreement than commonly reported in literature. The auto-delineations for high-risk and low-risk CTVs performed well in comparison to their respective clinically-used delineations (median DSC values of 0.81 and 0.82, respectively). Auto-delineated volumes provided improved delineation consistency compared to inter-physician variability (p<0.0001). Dosimetrically, coverage was acceptable (per RTOG 1016 guidelines) for 72% of auto-delineated plans when evaluated on clinically-used targets. The median percent-volume of clinically-used CTVs receiving 98% of the prescribed dose was 98% for auto-delineated CTV plans. We found no significant difference in normal tissue dose metrics between physician and auto-delineated target plans using a paired-Wilcoxon Rank-Sum Test: Brainstem Dmax (p=0.23), cord Dmax (p=0.87), contralateral parotid Dmean (p=0.41), and ipsilateral parotid Dmean (p=0.59).

Conclusion: We demonstrated that artificial intelligence-based algorithms can delineate high- and low-risk CTV with less variability than radiation oncologists. This work addresses a major barrier to fully-automated head-and-neck treatment planning by providing high-quality patient-specific CTVs.

Contact Email