MENU

Click here to

×

Are you sure ?

Yes, do it No, cancel

DISCLAIMER:
Entry of taxonomy/keywords during proffered abstract submission was optional.
Not all abstracts will appear in search results.

Education | IM | IM/TH | Leadership | TH | show all

Taxonomy: IM- CT: Dual Energy and Spectral

BReP-SNAP-I-48Spectral Inconsistency Analysis On a CdTe Photon-Counting Detector
Binxiang Qi*, Hewei Gao, Tsinghua University, Haidian Dist, 11CN,
PO-GeP-I-22Accuracy of Dual-Energy CT Virtual Non-Contrast/unenhanced and Material Density Images: A Phantom Study
B Li*, M Pomerleau, A Gupta, J Soto, S Anderson, Boston University Medical Center, Boston, MA
PO-GeP-I-77Detectability of Urinary Stone Sizes and Compositions by Various Scanning Parameters in Dual Energy CT
J Shin, J Shin*, Asan Medical Center
PO-GeP-I-96Dual Energy CT Protocol Optimization for Increased Blood Detectability of Virtual Non-Contrast Images in a Single Source Dual Energy CT System: A Phantom Study
C Olguin*, S Leon, I Barreto, R De Jesus, M Arreola, University of Florida College of Medicine, Gainesville, FL
PO-GeP-I-113Evaluation of Dual-Energy CT Reconstructed Virtual Monoenergetic Images for Radiation Therapy Treatment Planning
B Broekhoven*, W Godwin, D McDonald, Medical University of South Carolina, Charleston, SC
PO-GeP-I-139Improvement of Image Quality Using Image-Domain Multi-Material Decomposition Framework for Dual-Energy CT
H Lee*, H Kim, S Choi, Yonsei University, Wonju, GangwonKR,
PO-GeP-I-148Matching Convolution Kernels and Iterative Reconstruction for Quantitative Accuracy and Noise Power Spectrum in Dual-Layer and Dual-Source Spectral CT
G Anthony*, Y Liang, Indiana University, Indianapolis, IN
PO-GeP-I-180Quantitative Image Guided DECT Interventions: A Potential New Theranostic for Thermochemical Ablation
E Thompson*, M Jacobsen, R Layman, E Cressman, UT MD Anderson Cancer Center, Houston, TX
PO-GeP-I-209The Effect of Reconstruction Filters On Dual Energy CT Images From a Single-Source Sequential System
C Olguin*, I Barreto, S Leon, C Schaeffer, A Heshmat, M Arreola, University of Florida College of Medicine, Gainesville, FL
PO-GeP-M-212Evaluation of the Direct Density Algorithm for Energy-Independent Radiotherapy Planning
A Shutler1*, A Sarkar1, G Grousset2, J Shah2, F Mourtada1, (1) Christiana Care Health System, Newark, DE, (2) Siemens Healthineers USA, Malvern, PA
TH-AB-TRACK 4-2Using Virtual Non-Contrast CT From Dual-Energy CT to Eliminate the Need for Pre-Contrast CT for Radiation Therapy Planning of Pancreatic Cancer Patients
G Noid1*, A Tai1, D Schott1, J Zhu1, J Shah2, E Paulson1, D Prah1, X Li1, (1) Medical College of Wisconsin, Milwaukee, WI, (2) Siemens Healthineers, Durham, NC
TH-C-TRACK 1-1Adaptive Spectral Inconsistency Modeling for Photon-Counting Detector CT
Binxiang Qi, Hewei Gao*, Tsinghua University, Haidian Dist, 11CN,
TH-C-TRACK 1-2Establishing Quality Control Action Limit for Spectral CT Imaging Using ACR CT Phantom and Longitudinal Measurements
X Duan*, Y Zhang, J Anderson, UT Southwestern Medical Center, Dallas, TX
TH-C-TRACK 1-5Identifying Active Marrow Using Dual Energy CT Multi-Material Decomposition
Q Lyu1*, J Miller2, R Savjani1, M Lawless2, E McKenzie1, K Sheng1, (1) UCLA School of Medicine, Los Angeles, CA, (2) University of Wisconsin-Madison, Madison, WI,
TH-C-TRACK 1-6Investigation of Spectral Separation, Effective Energy, and Dose Allocation of Split-Filter DECT Using MCNP
L Di Maso*, M Lawless, J Huang, J Miller, L DeWerd, University of Wisconsin-Madison, Madison, WI
TH-C-TRACK 1-7Synthetic Dual Energy CT Images From Single Energy CT Image for Proton Radiotherapy
S Charyyev, T Wang*, Y Lei, B Bradshaw Ghavidel, J Beitler, M McDonald, W Curran, T Liu, J Zhou, X Yang, Emory Univ, Atlanta, GA
WE-F-TRACK 5-0Dual Energy CT Applications in Radiotherapy
B Teo1*, J Miller2*, (1) University of Pennsylvania, Philadelphia, PA, (2) University of Wisconsin-Madison, Madison, WI