Taxonomy: TH- Radiation Dose Measurement Devices: diodes/solid state

PO-GeP-T-113Application of IAEA TRS-483 Protocol for Validating the Collimator Output Factors of a Gamma Knife Unit Using Diode Detectors
S Cyriac1*, J Liu2, E Calugaru2, J Chang2,3, (1) KIMS Cancer Care and Research Center Pvt Ltd, Trivandrum, KL, IN, (2) Northwell Health and Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, Lake Success, NY, (3) Hofstra University, Hempstead, NY
PO-GeP-T-168CdTe-Based Semiconductor Detector for Correction-Less Small-Field Dosimetry
F Akbari*, D Shvydka, E Parsai, University of Toledo Medical Center, Toledo, OH
PO-GeP-T-179Characterization of the PTW MicroSilicon Detector
A Turnidge1*, M Heard1, S Junell1, (1) Oregon Health & Science University, Portland, OR
PO-GeP-T-253Cyberknife MultiPlan IMRT QA Comparison Between MapCHECK2 and SRS MapCHECK
W Feng1*, J Feng2, J Yang3, J Zhou4, C Yang5, L Zhou6, J Sakellakis7, P Abbass8, (1) Saint Barnabas Medical Center, Livingston, NJ, (2) Philadelphia Cyberknife, Havertown, PA, (3) Alliance Imaging/Alliance Oncology, Havertown, PA, (4) Rutgers Robert Wood Johnson Medical School, New Brunswick, NJ, (5) Monmouth Medical Center, Long Branch, NJ, (6) Livingston, NJ, (7) Clara Maass Medical Center, Montville, NJ, (8) 21st Century Oncology, Jupiter, FL
PO-GeP-T-313Dose-Rate and "SSD" Dependence of Commercially Available Diamond and Diode Detectors
A Khan*, W Culberson, L DeWerd, Dept of Med Phys, School of Medicine and Public Health, Univ of Wisc-Madison
PO-GeP-T-495Impact of the Change in the Mean Excitation Energy of Diamond On Energy Deposition in Different Beam Qualities
V Kaveckyte1,2*, A Carlsson Tedgren1,2, J M Fernandez-Varea3, (1) Linkoping University, Linkoping, Sweden, (2) Karolinska University Hospital, Stockholm, Sweden, (3) Barcelona University, Barcelona, Spain
PO-GeP-T-621Output Factor Measurements with Multiple Unshielded Dosimeters In Cyberknife Robotic Radiosurgery System
M Manavalan1*, M Duraisamy2, G Narayanasamy3, S Stathakis4, F Godson5, S Vikraman6, (1) PTW, New York, NY, (2) Medanta The Medicity Hospital, Gurgaon, India, (3) University of Arkansas for Medical Sciences, Little Rock, AR, (4) Mays Cancer Center - MD Anderson Cancer Center, San Antonio, TX, (5) Christian Medical College, Vellore, India, (6) The Brunei Cancer Centre (TBCC), Brunei