DISCLAIMER:
Entry of taxonomy/keywords during proffered abstract submission was optional.
Not all abstracts will appear in search results.
Taxonomy: TH- Brachytherapy: GYN Intracavity Brachytherapy
BReP-SNAP-M-59 | Development of a Machine Learning Algorithm for Hybrid Interstitial Needle Prediction in High-Dose-Rate Cervical Brachytherapy K Stenhouse*, M Roumeliotis, P McGeachy, Tom Baker Cancer Centre/University of Calgary, Calgary, AB, CA |
BReP-SNAP-T-40 | Developing a Novel 3D Print-Based Phantom to Facilitate Ultrasound-Guided Interstitial Gynecologic Brachytherapy Training Simulation Z Xiong*, D Parsons, Y Zhong, B Gannavarapu, C Nwachukwu, M Folkert, X Jia, P Medin, K Albuquerque, B Hrycushko, T Chiu, UT Southwestern Medical Center, Dallas, TX |
BReP-SNAP-T-49 | Dosimetric Performance of the Venezia™ Advanced Gynecological Applicator for Cervical Adenocarcinoma Boost Treatments: An Initial Statistical Evaluation of 125 Treatments E Schnell*, S Thompson, S Ahmad, T Herman, T De La Fuente Herman, University of Oklahoma Health Sciences Center, Oklahoma City, OK |
PO-GeP-P-3 | Considering Cost in New Facility and Program Design for Gynecologic Brachytherapy; a Comparison of Treatments for Locally Advanced Cervical Cancer M Roumeliotis*, S Quirk, K Thind, P Mcgeachy, T Phan, D Van Elburg, R Banerjee, K Martell, C Doll, W Smith, A Cameron, T Meyer, University of Calgary, Calgary, AB, CA, |
PO-GeP-T-162 | Brachytherapy Workflow for Locally Advanced Cervical Cancer: A Survey of Canadian Medical Physicists G Menon*, L Baldwin, B Burke, A Heikal, Cross Cancer Institute, Edmonton, AB, CA |
PO-GeP-T-196 | Commissioning and Dosimetric Analysis of Indigenously Developed Interstitial Plus Intracavitary Gynaecological Template in High Dose Rate Brachytherapy Venkatesan Kaliyaperumal*, S Banerjee, S Abraham, D Kamaraj, M Raju, D Manigandan, T Kataria, Medanta The Medicity, Gurgaon, Haryana, INDIA, |
PO-GeP-T-333 | Dosimetric Comparison of Vaginal Ovoid with Cylinder Brachytherapy for Borderline Size of Tumor at the Vaginal Cuff X Wu*, A Nikolaev, D Bridges, S Shen, R Kim, Univ Alabama Birmingham, Birmingham, AL |
PO-GeP-T-335 | Dosimetric Effect of the Applicator Removal From Target Volumes for Cervical Cancer Patients Treated with the Venezia Applicator Z Xu1*, B Traughber1,2, E Harris1,2, T Podder1,2, (1) University Hospital Seidman Cancer Center, Cleveland, OH, (2) Case Western Reserve University, Cleveland, OH |
PO-GeP-T-368 | Effect of Systematic Error of Ovoid Path Reconstruction in Cervical Cancer Brachytherapy Treatment Using Venezia Applicator M Paudel1*, J Da Re2, A Shaaer3, E Leung1, A Ravi1, (1) Sunnybrook Odette Cancer Center, University of Toronto, Toronto, ON, CA, (2) McMaster University, Hamilton, ON, CA,(3) Ryerson University, Toronto, ON, CA |
PO-GeP-T-377 | Endometrial Treatments with Electronic Brachytherapy. Comparison to Ir192 and Co60 HDR Sources S Lozares1*, A Gandia1, V Alba1, S Jimenez1, M Hernandez1, J Font1, D Villa1, A Campos2, S Flamarique2, (1) Medical Physics Department Hospital Universitario Miguel Servet, Zaragoza (Spain), (2) Radiation Oncology Department Hospital Universitario Miguel Servet, Zaragoza, (Spain) |
PO-GeP-T-387 | Establishing Total Time Index as An Investigative Parameter for Radiation Protection of Patients Undergoing High-Dose-Rate Brachytherapy E Oyekunle1*, R Obed2, B Akinlade3, (1) University College Hospital, Mokola, OY, NG, (2) University of Ibadan,Ibadan, OY, NG, (3) University of Ibadan, College of Medicine, Univ. College Hospital, Ibadan, Ibadan, OY, NG |
PO-GeP-T-451 | Feasibility of Patient Specific 3D-Printed Template to Increase Coverage of Advanced Gynaecological Applicator Venus W.Y. Lee1*, K. K. Kwan1, Winnie W. L. Yip1, Steven Cheung1, Victor H. F. Lee2, (1) Tuen Mun Hospital, Hong Kong, HK, (2) The University Of Hong Kong, HK |
PO-GeP-T-516 | Incorporating Total Treatment Time Into Butterfly Optimization for Vaginal Cylinder Brachytherapy X Wu*, I Brezovich, S Shen, E Covington, D Stanley, R Popple, Univ Alabama Birmingham, Birmingham, AL |
PO-GeP-T-517 | Incorporation of Experimental Uncertainties Associated with in Vitro Determination of Radiobiological Parameters Used in Cervical Cancer Brachytherapy B Chow*, B Warkentin, A Gamper, G Menon, University of Alberta, Edmonton, AB, CAN |
PO-GeP-T-526 | Interfraction Dose Deviation and Catheter Position in Cervical Interstitial and Intracavitary Image Guided HDR Brachytherapy Y Xu*, T Harris, D O'Farrell, L Lee, M King, I Buzurovic, Brigham & Women's Hospital, Harvard Medical School, Boston MA |
PO-GeP-T-527 | Intracavitary Versus Combined Intracavitary/Interstitial Applicators During High Dose Rate (HDR) Image Guided Adaptive Brachytherapy (IGABT) for Cervical Cancer: A Dosimetric Comparison D Soultan*, T Bodine, A Hoover, Kansas University Medical Center, Department of Radiation Oncology, Kansas City, KS |
PO-GeP-T-528 | Intra-Fractional Dose Variation of HR-CTV and Applicator Shift in Image-Guided Brachytherapy for Cervical Cancer Y Takayama1*, K Edamitsu1, H Matsukawa2, K Matsumoto1, Y Kasai3, K Inoue1, T Hirose4, J Fukunaga4, Y Shioyama1, T Sasaki1, (1)Kyushu Univ. , Fukuoka-shi, Fukuoka-ken (2)Univ. of Occupational and Environmental Health, Kitakyushu-shi, Fukuoka-ken, JP,(3)Nagoya City Univ. Hosp. , Nagoya-shi, Aichi-ken, JP ,Fukuoka, ,JP, (4) Kyushu Univ. Hosp. , Fukuoka-shi, Fukuoka-ken, JP |
PO-GeP-T-679 | Quantitative Analysis and Quality Assurance (QA) of Gynecological Brachytherapy Applicators Using Radiochromic Film Dosimetry S Aldelaijan1,2,3*, Y Khouj1, M Khosravi1, T Harris1, D O'Farrell1, M Jacobson1, J Seuntjens2, S Devic2,4, I Buzurovic1, (1) Brigham and Women's Hospital, Dana Farber Cancer Institute, Harvard Medial School, Boston, MA, (2) McGill University, Montreal, QC, CA, (3) King Faisal Specialist Hospital & Research Center, Riyadh, KSA, (4) Jewish General Hospital, Montreal, QC, CA, |
PO-GeP-T-717 | Sensitivity of Dose Distributions in Cervical Cancer Patients From Positioning Errors in Rotating Shield Brachytherapy K Hopfensperger1*, Q Adams2, Y Kim2, X Wu3, W Xu3, K Patwardhan2, B Thammavong2, R Flynn2, (1) Department of Biomedical Engineering, University of Iowa, Iowa City, IA, (2) Department of Radiation Oncology, University of Iowa Hospitals and Clinics, Iowa City, IA, (3) Department of Electrical and Computer Engineering, University of Iowa, Iowa City, IA. |
PO-GeP-T-761 | The Design of a Novel Direction Modulated Brachytherapy (DMBT) Vaginal Cylinder Using GEANT4 Monte Carlo Simulation Code M Meftahi*, W Song, Virginia Commonwealth University, Richmond, VA |
PO-GeP-T-762 | The Development of a Multi-Material 3D Printed Brachytherapy Training Phantom for Enhanced Resident Training S Campelo1*, E Subashi2, Z Chang3, S Meltsner3, J Chino3, O Craciunescu3, (1) Duke Medical Physics Graduate Program, Durham, NC, (2) Memorial Sloan Kettering Cancer Center, New York, NY, (3) Duke University Medical Center, Durham, NC |
PO-GeP-T-835 | Vaginal Cylinder HDR Brachytherapy: Effect of Inhomogeneity On Dose Calculation M Meftahi*, W Song, Virginia Commonwealth University, Richmond, VA |
TH-A-TRACK 3-6 | Custom Template Design and Manufacture Automation for Interstitial Gynecological Brachytherapy M Kudla1*,J Moore1,2,J Crook1,2,D Batchelar1,2, F Bachand1,2, (1) University of British Colombia, Kelowna, BC, CA, (2) BC Cancer - Kelowna, Kelowna, BC, CA |
TH-AB-TRACK 4-12 | Validation of a Machine Learning Algorithm for Applicator Selection in High-Dose-Rate Cervical Brachytherapy K Stenhouse*, M Roumeliotis, P McGeachy, Tom Baker Cancer Centre/University of Calgary, Calgary, AB, CA |
TU-C-TRACK 3-1 | A Novel Minimally Invasive Dynamic Shield System for Cervix Brachytherapy M Morcos1,2*, A Viswanathan2, S Abbasinejad Enger1,3,4, (1) Medical Physics Unit, McGill University, Montreal, QC, CA, (2) Johns Hopkins University, Baltimore, MD, (3) Department of Oncology, McGill University, Montreal, QC, CA, (4) Research Institute of the McGill University Health Centre, Montreal, QC, CA |