Taxonomy: IM/TH- Cone Beam CT: Quality Control
BReP-SNAP-I-8 | B0 Variation From Ferromagnetic Gantry Rotation H Gach*, A Curcuru, D Yang, O Green, S Mutic, T Kim, Washington University in St. Louis, St. Louis, MO |
BReP-SNAP-I-18 | Electronic X-Ray Field Alignment Detection E mckenzie1*, I Rutel2, (1) University of Alabama at Birmingham, Birmingham, AL, (2) University of Oklahoma Health Science Center, Oklahoma City, OK |
BReP-SNAP-I-24 | Implementation of CT Protocol Management Software to Detect Deviations From Master Protocols K Little1*, J Jacobs2, N Fitousi2, M Robins1, J Carpenter1, A Rupe1, D Hintenlang1, (1) Ohio State Univ, Columbus, OH, (2) Qaelum NV, Leuven, BE |
BReP-SNAP-I-30 | Investigation of the NPS as a Tool for Routine Quality Control of Digital X-Ray Systems M Ghorbanzade*, I Elbakri, CancerCare Manitoba, Winnipeg, MBCA, |
PO-GeP-I-11 | A Multifunction Software Tool for ACR MRI QC Evaluation and Accreditation Program J-X Wang*, W T Sobol, University of Alabama at Birmingham, Birmingham, AL |
PO-GeP-I-15 | A Phantom-Based Assessment of Low-Contrast Performance Comparing Iterative Reconstruction Algorithms in CT S Leon*, C Schaeffer, E Olguin, M Arreola, University of Florida, Gainesville, FL |
PO-GeP-I-38 | Automatic CT Air Bubble Artifact Detection in Routine QC Images A Verones1,2*, S Wong3, J Cheung4, T Lee4, T Bjarnason1,5,6, (1) University of British Columbia, Vancouver, CA, (2) Advanced Quality Systems, Inc., Vancouver, CA, (3) Tuen Mun Hospital, HK, (4) Prince of Wales Hospital, HK, (5) University of British Columbia, Okanagan, Kelowna, CA, (6) Interior Health, Kelowna, CA |
PO-GeP-I-54 | Clinical Impact Study of a New High Resolution Fluoroscopic Imager: Analysis of 400,000 Irradiation Events A Kuhls-Gilcrist*, M Hohn, N Xenos, D Marek, Y Hoi, Canon Medical Systems USA, Tustin, CA |
PO-GeP-I-57 | Comparison and Validation of Noise Magnitude Estimation Methods From Patient CT Images F Ria*, T Smith, E Abadi, J Solomon, E Samei, Duke University Health System, Durham, NC |
PO-GeP-I-67 | CT Exam Alert Level Setting, Evaluation, and Case Examples R Lamoureux*, D Sandoval, G Chambers, R Selwyn, University of New Mexico, Albuquerque, NM |
PO-GeP-I-117 | Evaluation of Phantom Image Quality with Curved and Flat Compression Paddle in 2D Mammography P Brunick*, J Yang, Kaiser Permanente Southern California Permanente Medical Group, Pasadena, CA |
PO-GeP-I-121 | Feasibility of An Analytical Medical Image Quality Assessment That Requires No User Input F Eashour*, S Pistorius, University of Manitoba, Winnipeg, MB, CA |
PO-GeP-I-133 | Image Quality in the Slice-Plane of Half-Reconstructed Computed Tomography in Filtered Back Projection and Iterative Reconstruction Methods N Tsuda1*, K Mitsui2, S Oda3, N Tanaka4, H Aibe5, (1) Division of Radiology, Saga-ken Medical Centre Koseikan, Saga-shi, ,JP, (2) Division of Radiology, Saga-ken Medical Centre Koseikan, Saga-shi, ,JP, (3) Division of Radiology, Saga-ken Medical Centre Koseikan, Saga-shi, ,JP, (4) Department of Health Sciences, Faculty of Medical Sciences, Kyushu University, Fukuoka-shi, ,JP, (5) Department of Radiology, Saga-ken Medical Centre Koseikan, Saga-shi, ,JP |
PO-GeP-I-138 | Impact of Scanner Speed On the Rate of Radiologist Complaint of Motion Artifact On Pediatric Body CT M Lipford*, T Szczykutowicz, University Wisconsin-Madison, Madison, WI |
PO-GeP-I-159 | Optimization and Validation of An Automatic Noise Measurement Algorithm for Clinical CT Image Data M Ahmad*, A Thomas, M Jacobsen, R Layman, K Brock, UT MD Anderson Cancer Center, Houston, TX |
PO-GeP-I-178 | Quantitative Evaluation of Image Quality of Deep-Learning-Based CT Reconstruction Using Structural SIMilarity (SSIM) K Yang*, A Parakh, R Gupta, A Kambadakone, X Li, B Liu, Massachusetts General Hospital, Harvard Medical School, Boston, MA |
PO-GeP-I-207 | The Design and Fabrication of a Dynamic Anthropomorphic Thorax Phantom Z Xu1*, Z Sun1, X Shi2, C Lin3, W Lu1, W Lu1, J Qiu1, L Shi1, (1) Shandong First Medical University & Shandong Academy of Medical Sciences, Taian, CN, (2) Shengli College, China university of petroleum, Dongying, CN, (3) Taian Disabled soldiers' Hospital of Shandong Province, Taian, CN |
PO-GeP-I-216 | Toward Developing a Practical Approach for Evaluating CT Scanner Tube Current Modulation Performance S Zhang*, J Provencher, R Subramaniam, Mount Sinai Medical Center, New York, NY |
PO-GeP-I-227 | Utilizing a Radiology-Based Informatics System to Impact Clinical Practice: A Study to Improve and Track Patient Alignment in Computed Tomography A Moody1*, L DeWeese2, T Griglock3, (1) UT Health San Antonio, San Antonio, TX, (2) Oregon Health & Science Univ, Portland, OR, (3) Oregon Health & Science Univ, Portland, OR |
PO-GeP-I-233 | Variations in Image Artifacts at Ultra-Low Radiation Dose Levels Due to Differences in Scanner Make and Model: Implications for CT Screening Applications J Browne, M Bruesewitz, Z Long*, T Vrieze, C McCollough, L Yu, Mayo Clinic, Rochester, MN |
PO-GeP-M-194 | Evaluating the Clinical Utility of Cherenkov Imaging in Radiotherapy R Hachadorian1*, D Alexander1, I Tendler1, M Jermyn1,2, B Pogue1,2,3, L Jarvis3, (1) Dartmouth College, Hanover, NH, (2) DoseOptics LLC, Lebanon, NH, (3) Dartmouth-Hitchcock Med. Ctr., Lebanon, NH |
PO-GeP-M-285 | Long Term Stability of KV Cone Beam CT (CBCT) Image Quality Assurance for IBA Proteus PLUS Proton Therapy System J George*, J Bennouna, S Rana, J Yu, L Coutinho, M Hobson, L Perles, S George, A Gutierrez, Miami Cancer Institute, Miami, FLORIDA, |
PO-GeP-P-12 | Clinical Review of Radiography Reject and Repeat Rate Changes After Upgrading From CR to DR R Fisher1*, (1) MetroHealth, Cleveland, OH |
PO-GeP-P-21 | Automated Quality Control for ACR Compliance M Christensen*, Massachusetts General Hospital, Boston, MA 02114 |
PO-GeP-P-26 | A Simple Test Tool to Optimize Protocol in Real Time Fluoroscopic Imaging R Livingstone*, B Pearline, A Singh, N Ahirwar, S Devasahayam, Christian Medical College, Vellore, TN IN, |
PO-GeP-P-93 | OBI Image Quality Assurance Using Process Capability Indices S Alani*, Y Tova |
TU-B-TRACK 1-1 | Variations in Signal-To-Noise Characteristics of Tissue-Equivalent Attenuators for Automatic Exposure Control System Performance Evaluation in Mammography C Morrison*, E Macdonald, N Bevins, Henry Ford Health System, Detroit, MI |
TU-B-TRACK 1-7 | Interim Annual QC Test Results for a Tomography Screening Trial A Maki*, M Yaffe, J Mainprize, G Mawdsley, O Alonzo-Proulx, Sunnybrook Research Institute, Toronto, ON CA, |
TU-D-TRACK 1-6 | Assessing Digital Image Receptor Performance Using the Noise-Response Method: A Feasibility Study for Routine Quality Control G Fong*, K Wunderle, Cleveland Clinic Foundation, Cleveland, OH |