MENU

Click here to

×

Are you sure ?

Yes, do it No, cancel

DISCLAIMER:
Entry of taxonomy/keywords during proffered abstract submission was optional.
Not all abstracts will appear in search results.

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # | show all

Keywords: let
BReP-SNAP-T-101Measurements of LET, Nuclear Halo, Energy and Angular Spectra of a Proton Spot Scanning Beam with a Hybrid Semiconductor Detector
S Charyyev1*, C Chang2, A Stanforth3,4, J Harms5, C Oancea6, L Lin7, (1) Emory University, Atlanta, GA, (2) Emory University, Atlanta, GA, (3) Emory University, Atlanta, GA, (4) Georgia Institute of Technology, Atlanta, GA, (5) Emory University, Atlanta, GA, (6) ADVACAM, Prague, CZ, (7) Emory Proton Therapy Center, Atlanta, GA
MO-CD-TRACK 1-3Multi-Ion Therapy: Development, Validation and Clinical Direction of a Novel Particle Treatment Modality
S Mein1,2*, B Kopp1,2, I Dokic1,2, S Harrabi1, TT Boehlen3, T Haberer1, J Debus1,2, A Abdollahi1,2, A Mairani1,4 (1) Heidelberg Ion-beam Therapy Center (HIT), Heidelberg, DE, (2) German Cancer Research Center (DKFZ), Heidelberg, DE, (3) Center for Proton Therapy, Paul Scherrer Institute (PSI), Villigen, Switzerland, (4) National Centre of Oncological Hadrontherapy (CNAO), Pavia, Italy
PO-GeP-T-305Did Proton High Linear-Energy Transfer (LET) Cause the Strange Smell During Cranial-Spinal Irradiation?
Z Su*, W Hsi, M Artz, D Indelicato, Radiation Oncology, University of Florida, Gainesville, FL and University Florida Health Proton Radiotherapy Institute, Jacksonville, FL,
PO-GeP-T-453Feasibility of Relating LETd Differences to Toxicity for Head & Neck Proton Therapy
D Wagenaar*, J Langendijk, A Van Der Schaaf, S Both, Department of Radiation Oncology, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
PO-GeP-T-541Investigation of Radiophotoluminescent Glass Dosimeter Response for a Spot Scanning Proton Beam Dosimetry
J Nagata*, K Yasui, N Hayashi, S Ogawa, K Ouchi, Graduate school of Health Sciences, Fujita Health University, Toyoake, AichiJP,
PO-GeP-T-561LET Painting Through Proton Mono-Energetic Arc Therapy (PMAT) to Enhance Radiobiological Effectiveness
A Bertolet*, A Carabe, Hospital of the University of Pennsylvania, Philadelphia, PA
PO-GeP-T-656Preliminary Clinical Analysis with Dose-Averaged LET Calculation for Head and Neck Cancer Patients Treated by Using Carbon-Ion Radiotherapy
S Lee1*, A Yamamoto1, K Yamaoka1, E Hotta1, M Yamamoto1, Y Suzuki2, A Inomata2, M Suga3, M Koto1, R Kohno1, (1)National Institutes for Quantum and Radiological Science and Technology, Chiba, JP (2)Accelerator Engineering Corporation, Chiba, JP (3)Kanagawa Cancer Center, Kanagawa, JP
PO-GeP-T-663Proton Energy Spectrum-Based Linear Energy Transfer Measurement
W Yao1*, (1) University of Maryland School of Medicine, Baltimore, MD
PO-GeP-T-664Proton Linear Energy Transfer Differs According to Beam Delivery Method
L Wilson*, F Pirlepesov, V Moskvin, T Merchant, A Faught, St. Jude Children's Research Hospital, Memphis, TN
PO-GeP-T-695RBE Calculation Using the Survival Simulation Tool for HSG, V79 and CHO Cells Irradiated by 12C, 20Ne and 3He Ions
M Suga1,3*, T Honma2, S Lee3, M Suzuki3, H Katou1, M Hashimoto2, K Tanimoto3, R Kohno3, (1) Kanagawa Cancer Center, Kanagawa, JP(2)International University of Health and Welfare Graduate school, Tochigi, JP(3)National Institute of Radio. Sciences, Chiba, JP
WE-B-TRACK 3-3INSPIRE: A Multi-Centric Study to Harmonize Linear Energy Transfer (LET) Calculations for Biological Assessments of Proton Therapy Plans
J Oden1, 2*, C Hahn3, A Vestergaard4, M Fuglsang Jensen4, O Sokol5, C Pardi6, F Bourhaleb6, A Leite7, L De Marzi7, C Rose8, K Kirkby8, E Smith8, M Merchant8, L Grzanka9, A Dasu10, A Luehr3, 11, (1) RaySearch Laboratories AB, Stockholm, SE, (2) Stockholm University, Stockholm, SE, (3) OncoRay, National Center for Radiation Research in Oncology, Dresden, DE, (4) Danish Centre For Particle Therapy, Aarhus, DK, (5) GSI Helmholtz Centre For Heavy Ion Research, Darmstadt, DE, (6) I-SEE (Internet-Simulation Evaluation, Envision), Torino, IT, (7) Institut Curie, Orsay, FR, (8) University of Manchester, Manchester, UK, (9) Institute of Nuclear Physics Polish Academy of Sciences, Krakow, PL, (10) The Skandion Clinic, Uppsala, SE, (11) Technical University Dortmund, Institute of Medical Physics, Dortmund, DE
WE-B-TRACK 3-5Dose-Linear Energy Transfer (LET) Volume Histogram (DLVH) for Adverse Events in Prostate Cancer Patients Treated by Intensity-Modulated Proton Therapy (IMPT)
Y Yang*, C Vargas, R Bhangoo, W Wong, S Schild, T Daniels, S Keole, J Rwigema, J Shen, M Fatyga, W Liu, Mayo Clinic Arizona, Phoenix, AZ
WE-B-TRACK 3-7Voxel-Based Dose-Linear Energy Transfer (LET) Volume Histogram (DLVH) to Study Adverse Events in Head and Neck (H&N) Cancer Treated by Intensity-Modulated Proton Therapy (IMPT)
Y Yang1*, S Patel2, J Bridhikitti3, M Halyard4, L McGee5, J Rwigema6, W Wong7, M Bues8, M Fatyga9, R Foote10, W Liu11, (1) Mayo Clinic Arizona, Phoenix, AZ, (2) Mayo Clinic Arizona, Phoenix, AZ, (3) Prince of Songkla University, ,Songkhla, TH, (4) Mayo Clinic Arizona, Phoenix, AZ, (5) Mayo Clinic Arizona, Phoenix, AZ, (6) Mayo Clinic Arizona, Phoenix, AZ, (7) Mayo Clinic Arizona, Phoenix, AZ, (8) Mayo Clinic Arizona, Phoenix, AZ, (9) Mayo Clinic Arizona, Phoenix, AZ, (10) Mayo Clinic Rochester, Rochester, MN, (11) Mayo Clinic Arizona, Phoenix, AZ
WE-D-TRACK 3-6RBE for STING Immunogenic Signaling From Low LET X-Rays and High LET Neutrons
D Miles1,2*, N Cao2, T Pulliam2, S Cherny2, R Stewart2, G Moffitt2, G Sandison2, P Nghiem2, P Goff2, E Hatch3, K Stantz1, (1) Purdue Univ, West Lafayette, IN, (2) University of Washington, Seattle, WA,(3) Fred Hutchinson Cancer Research Center