MENU

Click here to

×

Are you sure ?

Yes, do it No, cancel

DISCLAIMER:
Entry of taxonomy/keywords during proffered abstract submission was optional.
Not all abstracts will appear in search results.

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # | show all

Keywords: in vivo dosimetry
BReP-SNAP-T-87Influence of the Magnetic Field On the Cherenkov Light Collected by Optical Fiber Dosimeters
B Maraghechi1*, Y Hao1, R Zhang2, H Li1, S Mutic1, A Darafsheh1, (1) Washington University School of Medicine, St. Louis, MO, (2) Dartmouth College, Lebanon, NH
BReP-SNAP-T-112Plastic Scintillation Detector Calibration Procedure for Brachytherapy in Vivo Dosimetry
A Herreros1, J Perez-Calatayud2*, F Ballester3, (1) Hospital Clinic Barcelona, Barcelona, ,ES, (2) Hospital La Fe, Valencia, ,ES, (3) University of Valencia, Burjassot, ,ES
MO-E-TRACK 2-1BEST IN PHYSICS (MULTI-DISCIPLINARY): First-In-Human Use of Prompt Gamma-Ray Spectroscopy for Proton Range Verification
J Verburg*, F Hueso-Gonzalez, S Tattenberg, P Wohlfahrt, T Ruggieri, T Bortfeld, Massachusetts General Hospital and Harvard Medical School, Boston, MA
PO-GeP-I-3A Body Mass Index-Based Method for Size-Specific Dose Estimates (SSDE) in Adults
D Yan1,2*, B Chen2, W Lu1, J Qiu1, L Shi1, (1) Shandong First Medical University & Shandong Academy of Medical Sciences, Taian, CN (2) Hwamei Hospital, university Of Chinese Academy Of Sciences, Ningbo, CN
PO-GeP-I-60Comparison of Lens Dose Received During 2.5 MV and 6 MV Imaging
T Tran*, B Subramanian, GenesisCare, Melbourne, VIC, AU
PO-GeP-I-88Directly Measuring Peak Skin Dose During Fluoroscopically-Guided Neuroradiology Interventional Surgeries
N Quails*, D Laurent, B Corliss, B Hoh, A Polifka, W Fox, L Rill, M Arreola, University of Florida, Gainesville, FL
PO-GeP-M-262Initial Investigation of Dose Calculation On Intra-Irradiation Cone-Beam CT Images
H Iramina*, M Nakamura, T Mizowaki, Kyoto University, Graduate School of Medicine, Kyoto, JP
PO-GeP-M-430VMAT Case Study for Patient Specific Virtual Compensator Algorithm EPID In-Vivo Dosimetry
J Barbiere*, R Teboh Forbang, A Ndlovu, Hackensack Univ Medical Center, Hackensack, NJ
PO-GeP-P-31Standard of Care Total Body Irradiation for Scleroderma: Duke Institutional Implementation
A Rodrigues, O Craciunescu*, Q Wu, N Larrier, Duke University Medical Center, Durham, NC
PO-GeP-T-40A Novel Absolute Radiation Dosimetry Approach Measuring Reactive Oxygen Species
J Rahimian*, M Hitchler, Kaiser Permanente Los Angeles Medical Center, Los Angeles, CA
PO-GeP-T-211Comparing Surface Dose in Pinnacle and Eclipse Using a Commercial OSLD
W Short*, J Yakoubian, Carti Cancer Center, Little Rock, AR
PO-GeP-T-266Detectability of MLC Stop Position Error During Treatment by Gantry-Mounted Transmission Detector
H Honda1,2*, M Tominaga3,M Sasaki4,Y Uto5,M Oita6, Y Hamamoto7,T Mochizuki8,T Kido9,Y Ishii10,R Yamamoto11,K Omoto12 (1) Department of Radiological Technology, Ehime University Hospital, Ehime, JP, (2) Graduate School of Advanced Technology and Science, Tokushima University, Jp, (3) Institute of Biomedical Sciences, Tokushima University Graduate School, Tokushima, JP, (4) Institute of Biomedical Sciences, Tokushima University Graduate School, Tokushima, JP, (5) Institute of Bioscience and Bioindustry, Tokushima University, Tokushima, Jp, (6) Okayama University Graduate School of Interdisciplinary Science and Engineering in Health Systems, Okayama, JP, (7)Department of Radiological Technology, Ehime University Hospital, Ehime, JP,(8) Department of Radiological Technology, Ehime University Hospital, Ehime.JP,(9) Department of Radiology, Ehime University Graduate School of Medicine, Ehime, JP, (10) Department of Radiological Technology, Ehime University Hospital, Ehime, JP, (11) Department of Radiological Technology, Ehime University Hospital, Ehime, JP, (12) Department of Radiological Technology, Ehime University Hospital, Ehime, JP,
PO-GeP-T-267Detection of Errors in HDR Brachytherapy With An in Vivo Dosimeter With Real-Time Positional Tracking Information
D Tho1,2*, L Beaulieu1,2, (1) Departement de radio-oncologie et Centre de recherche du CHU de Quebec CHU, Quebec,QC,CA, (2) Departement de physique de genie physique et doptique, et Centre de recherche sur le Cancer, Universite Laval, Quebec, QC, CA
PO-GeP-T-514In Vivo Dosimetry with XR RV3 Radiochromic Films in IORT
S Lozares1*, D Villa1, M Hernandez1, A Gandia1, S Jimenez1, V Alba1, J Font1, S Flamarique2, A Campos2, (1) Medical Physics Dept. Hospital Universitario Miguel Servet, Zaragoza,(Spain), (2)Radiation Oncology Dept. Hospital Universitario Miguel Servet, Zaragoza, (Spain)
PO-GeP-T-543Investigation of the Dosimetric Accuracy of Treatment Planning for Total Body Irradiation Using Extended Distance Technique
A Eldib1*, T Lin1, J Liu1, M Hossain1, M Afifi2, R Price1, C Ma1, (1) Fox Chase Cancer Center, Philadelphia, PA, (2) Faculty of Applied Medical Sciences,Prince Sattam bin Abdulaziz University
PO-GeP-T-646Pre-Clinical and Clinical Evaluation of the HYPERSCINT Scintillation Dosimetry Research Platform
I Schoepper1, E Trestrail2*, S Dieterich3, M Kent4, (1) WR Pritchard Veterinary Medical Teaching Hospital, UC Davis School of Veterinary Medicine, UC Davis School Of Veterinary Medicine, (2) Pacific Crest Medical Physics ,Chico, CA, (3) UC Davis Medical Center, Sacramento, CA, (4) Surgical and Radiological Sciences, UC Davis School of Veterinary Medicine, Davis, CA,
PO-GeP-T-647Preclinical Application of Electronic Portal Imaging Device
Akbar Anvari,1,2 Amit Sawant2 (1) Department of Radiation Oncology, Perelman Center for Advanced Medicine, University of Pennsylvania, Philadelphia, PA, USA (2) Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, MD, USA
PO-GeP-T-678Quantifying Patient Shifts Using In Vivo EPID Images
J Zavala Bojorquez*, C Bojechko, University of California San Diego, La Jolla, CA
PO-GeP-T-697Real-Time In-Vivo Dose Tracking for Scalp Cutaneous Lymphoma Treated with Electron: First Time Application of E-PSD for Patient Dose Tracking
Z Xu1*, C Langmack1, A Bhatt1,2, T Baig1, B Traughber1,2, E Harris1,2, T Podder1,2, (1) University Hospital Seidman Cancer Center, Cleveland, OH,(2) Case Western Reserve University, Cleveland, OH
PO-GeP-T-698Real-Time MOSkin In-Vivo Rectal Dosimetry for TRUS Based HDR Prostate Brachytherapy
J Poder1,2*, A Howie1, R Brown1, J Bucci1, A Rosenfeld2, K Enari1, K Schreiber1, M Carrara3, D Malouf1, D Cutajar2, (1) St George Cancer Care Centre, Kogarah, NSW, AUS (2) University of Wollongong, Wollongong, NSW ,AU, (3) Fondazione IRCCS Istituto Nazionale dei Tumori, Milano, IT
PO-GeP-T-743Strontium Aluminate Phosphorescent Materials: Bright Idea for in Vivo Dosimetry
X Tang*, E Ehler, D Mathew, University of Minnesota, Minneapolis, MN
PO-GeP-T-811Treatment Planning Verification of In-Vivo OSLD Phantom Measurements
A Bowers*, J Keller, Thomas Jefferson University, Philadelphia, PA