MENU

Click here to

×

Are you sure ?

Yes, do it No, cancel

DISCLAIMER:
Entry of taxonomy/keywords during proffered abstract submission was optional.
Not all abstracts will appear in search results.

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # | show all

Keywords: gamma knife
BReP-SNAP-T-48Dosimetric Evaluation of Static and Rotating Gamma Ray Systems for Intracranial SRS/SRT
Q Jiang 1*, A Eldib2, L Chen3, D wu4, B Wang5, S Li6, C Miyamoto7, J Li8, B Nguyen9, C Ma10, (1) The First Affiliated Hospital of Chongqing Medical University, Chongqing, China, (2) Fox Chase Cancer Center, Philadelphia, PA (3) Fox Chase Cancer Center, Philadelphia, PA (4) The People`s Hospital of Guangxi Zhuang Autonomous Region ,Guangxi, China (5) Temple University Hospital, Philadelphia, PA, (6) Temple University Hospital, Philadelphia, PA (7) Temple University, Philadelphia,(8) ,Huntingdon Valley, PA, (9) Prowess Inc., Concord, CA, (10) Fox Chase Cancer Center, Philadelphia, PA
MO-F-TRACK 2-2A Deep Learning Based Segmentation and Evaluation Framework for Brain Metastases Follow-Up After Stereotactic Radiosurgery
Z Yang1*, L Wang2, Y Liu3, M Chen1, E Zhang1, R Timmerman1, T Dan1, Z Wardak1, W Lu1, X Gu1, (1) UT Southwestern Medical Center, Dallas, TX (2) University Of Texas At Arlington, TX (3) Sichuan University, Chengdu, CN
PO-GeP-M-44Accuracy of the 3D Reference Coordinate Definition with G-Frame for Gamma Knife ICON
L Claps*, D Mathew, Y Watanabe, University of Minnesota, Minneapolis, MN
PO-GeP-M-385Stereotactic Space Definition Accuracy in the Latest Gamma Knife Icon Based Radiosurgery
B Liu1*, T Cui1, N Yue1, S Danish1, J Weiner1,K Nie1, (1) Rutgers Cancer Institute of New Jersey, New Brunswick, NJ
PO-GeP-T-33D-Printed Headrest for Frameless Gamma Knife Radiosurgery: Design and Validation
G Baltz*, T Briere, D Luo, R Howell, S Krafft, E Han, MD Anderson Cancer Ctr., Houston, TX
PO-GeP-T-62A Preliminary Study On Quality Control for Treatment Planning of Gamma Knife Radiosurgery for Vestibular Schwannoma
Z Tian*, T Wang, X Yang, D Giles, E Butker, M Walb, W Curran, S Kahn, T Liu, Winship Cancer Institute, Emory University, Atlanta, GA
PO-GeP-T-113Application of IAEA TRS-483 Protocol for Validating the Collimator Output Factors of a Gamma Knife Unit Using Diode Detectors
S Cyriac1*, J Liu2, E Calugaru2, J Chang2,3, (1) KIMS Cancer Care and Research Center Pvt Ltd, Trivandrum, KL, IN, (2) Northwell Health and Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, Lake Success, NY, (3) Hofstra University, Hempstead, NY
PO-GeP-T-117Are All Volumes of Brain Metastases Suitable for Linac-Based Stereotactic Radiosurgery?
C Liu*, S Ahmed, T Ma, G Neyman, J Suh, P Xia, The Cleveland Clinic Foundation, Cleveland, OH
PO-GeP-T-229Comparison of Reference Dosimetry Protocols for Small Radiosurgery Fields
Z Iqbal*, T Chiu, D Parsons, A Godley, X Gu, S Stojadinovic, UT Southwestern Medical Center, Dallas, TX
PO-GeP-T-325Dosimetric Comparison Between Two Dose Calculation Algorithms Available in Gamma Knife Planning System (the Traditional TMR10 and the New Convolution Algorithms)
M Fager1*, A Carlsson Tedgren1, M Gubanski2, P Forander3, H Benmakhlouf1, (1) Department of Radiotherapy Physics and Engineering, Karolinska University Hospital, Solna, AB, SE, (2) Department Of Radiation Oncology, Karolinska University Hospital,Solna, AB, SE,(3) Department Of Neurosurgery, Karolinska University Hospital,Solna, AB, SE,
PO-GeP-T-327Dosimetric Comparison of Gamma Knife(R) IconTM and Linear Accelerator-Based FSRT Plans for the Re-Irradiation of Large (> 14 Cc) Recurrent Glioblastomas
M Schelin*, H Liu, W Shi, Y Yu, K Mooney, Thomas Jefferson University, Philadelphia, PA
PO-GeP-T-360Dynamic Dose Measurements of Gamma Knife ICON Using a New Scintillation Detector System
Y Watanabe*, M Feijoo, S Beron, G Perera, University of Minnesota, Minneapolis, MN
PO-GeP-T-422Evaluation of the W2-Scintillator Detector for Routine QA of the Leksell Gamma Knife
B Rudek*, K Bernstein, T Qu, NYU Langone Health, New York, NY
PO-GeP-T-439Experimental Verification of Reference Dosimetry Correction Factors for Leksell Gamma Knife Icon Beams
W Hager1*, V Kaveckyte2,3, H Benmakhlouf3, (1) Dept. of Physics, Stockholm University, Stockholm, SE, (2) Dept. of Medical and Health Sciences, Linkoping University, Linkoping, SE, (3) Dept. of Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Stockholm, SE
PO-GeP-T-460Filmless Quality Assurance Tests for the Leksell Gamma Knife Icon™
B Maraghechi*, T Kim, J Dise, S Goddu, T Mitchell, J Kavanaugh, J Zoberi, S Mutic, N Knutson, Washington University, St. Louis, MO
PO-GeP-T-485Imaging the Effective Point of Measurement of a Dosimeter Inside a Phantom
S Cyriac1*, J Liu2, E Calugaru2, J Chang2,3, (1) KIMS Cancer Care and Research Center Pvt Ltd, Trivandrum, KL, IN, (2) Northwell Health and Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, Lake Success, NY, (3) Hofstra University, Hempstead, NY
PO-GeP-T-502Implementation of New QA Method for Source Sector Movement Verification in Gamma Knife Radiosurgery
GOPISHANKAR NATANASABAPATHI*, RAJKISHOR BISHT, SUBASH CHANDER, SS KALE, All India Institute of Medical Sciences New Delhi IN
PO-GeP-T-554Is the Transient Dose Significant and Is It Compensated in Gamma Knife ICON?
T Qu1*, (1) NYU Langone Medical School, New York, NY
PO-GeP-T-571Manipulating Gamma Knife Collimator Size in Treatment Planning to Improve Plan Quality
CJ Tien, JE Bond*, N Nguyen, Z Chen, Yale Univ. School of Medicine & YNHH, New Haven, CT
PO-GeP-T-604Novel Radiochromic Films for Dosimetry in Gamma Knife Stereotactic Radiosurgery
A Mittal1*, N Gopishankar2, A Verma3, P Kumar4, (1) All India Institute Of Medical Sciences, New Delhi, IN (2) All India Institute of Medical Sciences, New Delhi, IN (3) University Of Delhi, Delhi, IN (4) All India Institute Of Medical Sciences, New Delhi, IN
PO-GeP-T-637Personalized Treatment Gating Thresholds in Frameless Stereotactic Radiosurgery Using Predictions of Dosimetric Fidelity and Treatment Interruption
R MacDonald1*, Y Lee1, J Schasfoort2, H Soliman1, A Sahgal1, M Ruschin1(1) Sunnybrook Health Sciences Centre, Odette Cancer Centre, Toronto, ON, CA,(2) Gamma Knife Center Tilburg
PO-GeP-T-668PTV Margins for Gamma Knife Icon Frameless Treatment: A Validation Study
P Diagaradjane1*, E Han2, D Luo3, Y Ding4, G Kalaitzakis5, E Zoros6, K Zourari7, T Boursianis8, E Pappas9, Z Wen10, J Wang11, T Briere12, (1) The UT MD Anderson Cancer Center, Houston, TX, (2) UT MD Anderson Cancer Center, Houston, TX, (3) UT MD Anderson Cancer Center, Houston, TX, (4) MD Anderson Cancer Center, Houston, TX, (5) Department of Medical Physics, University of Crete, Heraklion, Crete, Greece , GR,(6) Medical Physics Laboratory, Medical School, National and Kapodistrian University of Athens, Athens 115 27, Greece, GR,(7) Medical Physics Laboratory, Medical School, National and Kapodistrian University of Athens, Athens 115 27, Greece, GR, (8) Department of Medical Physics, University of Crete, Heraklion, Crete, Greece, GR, (9) Department Of Biomedical Sciences, Of West Attica, Athens, Greece, ,,(10) MD Anderson Cancer Center, Houston, TX, (11) MD Anderson Cancer Center, Houston, TX, (12) MD Anderson Cancer Ctr., Houston, TX
PO-GeP-T-704Replacing Gamma Knife Beamprofiles On Film with Point-Detector Scans
B Rudek, T Qu*, K Bernstein, NYU Langone Health, New York, NY
PO-GeP-T-714Scanning Beam-Based Dose Delivery for Rotating Gamma Ray Systems for Intra- and Extra-Cranial SRS/SBRT
J Xu*, C Ma, Fox Chase Cancer Center, Philadelphia, PA
PO-GeP-T-856Workflow Analysis for Framed Gamma Knife Treatments
J Liu*, E Calugaru, J Chang, Northwell Health, Lake Success, NY
PO-GeP-T-857Workflow Analysis of Frameless Gamma Knife Treatments
J Liu*, E Calugaru, J Chang, Northwell Health, Lake Success, NY
TU-C-TRACK 3-4Multiresolution-Level Inverse Planning for Gamma Knife Radiosurgery for Vestibular Schwannoma
Z Tian*, X Yang, D Giles, T Wang, E Butker, M Walb, W Curran, S Kahn, T Liu, Winship Cancer Institution, Emory University, Atlanta, GA