Keywords: dosimetry protocols
BReP-SNAP-T-69FLASH Pencil Beam Scanning Proton Therapy in Clinical Gantry: Reference Dosimetry Inter-Comparison Including Ion Chambers and a Calorimeter
E Lee1*, A Lourenco2, J Speth1, N Lee2, R Thomas2, Y Zhang1, Z Xiao1, A Mascia1, (1) Univ of Cincinanti Med Ctr. Proton Therapy Ctr, Liberty Township, OH,(2) National Physical Laboratory, Teddington, UK
BReP-SNAP-T-85Improving Uncertainty in GammaPod Dose Through the Use of ND,w and IAEA TRS 483
B Yi*, S Becker, Univ. of Maryland School Of Medicine, Baltimore, MD
BReP-SNAP-T-135Update of the CLRP TG-43 Parameter Database for Brachytherapy Sources
H Safigholi1*, M J P Chamberland1,2, R E P Taylor1,3, C H Allen1, M P Martinov1, D W O Rogers1, R W Thomson1, (1) Carleton Laboratory for Radiotherapy Physics, Department of Physics, Carleton University, Ottawa, ON, CA (2) The University of Vermont Medical Center, Burlington, VT, USA (3) Multi Leaf Consulting, Port Elgin, ON, CA
PO-GeP-I-74Dental and Maxillofacial Cone Beam Computed Tomography Dose Index in Full-Fan and Full-Scan Mode
S Jia*, L Zhang, Y Xing, H Gao, Tsinghua University, Haidian Dist, 11CN,
PO-GeP-P-29Quality Control of Knowledge Assessment Questions for Training Courses Held On the IAEA/AAPM TRS-483 Small Field Dosimetry Code of Practice for Dosimetry
G Loreti, M Khandekar, K Christaki, D van der Merwe*, Iaea
PO-GeP-T-113Application of IAEA TRS-483 Protocol for Validating the Collimator Output Factors of a Gamma Knife Unit Using Diode Detectors
S Cyriac1*, J Liu2, E Calugaru2, J Chang2,3, (1) KIMS Cancer Care and Research Center Pvt Ltd, Trivandrum, KL, IN, (2) Northwell Health and Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, Lake Success, NY, (3) Hofstra University, Hempstead, NY
PO-GeP-T-210Comparing SBRT Lung Treatment Plans Using Acuros and AAA to Evaluate Dosimetric Guidelines
M Webster*, J Yeo, S Tanny, N Joyce, University of Rochester, Rochester, NY
PO-GeP-T-229Comparison of Reference Dosimetry Protocols for Small Radiosurgery Fields
Z Iqbal*, T Chiu, D Parsons, A Godley, X Gu, S Stojadinovic, UT Southwestern Medical Center, Dallas, TX
PO-GeP-T-265Details Count! Micrometric Airgaps Between Phantom Slabs Influence Film Dosimetry When Micro-Fractionated X-Ray Beams Are Used
P Pellicioli1*, M Donzelli1, R Hugtenburg2, F Esteve3, E Brauer-Krisch1, M Krisch1, (1) European Synchrotron Rad. Fac.,Grenoble, FR (2) Swansea University, Swansea, UK (3) UA7 Strobe, Grenoble, FR
PO-GeP-T-518Influence of Dosimeter Leakage Current On the Determination of Absorbed Dose to Water
N Kinoshita1*, A Takemura2, H Oguchi3, E Kidoya1, H Shioura4, H Kimura4, (1) Radiological Center, University of Fukui Hospital, JP, (2) Faculty of Health Sciences, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, JP, (3) Department of Radiological and Medical Laboratory Sciences, Nagoya University Graduate School of Medicine, JP, (4) Department of Radiology, University of Fukui Hospital, JP
PO-GeP-T-558Lead Foil for Flattening Filter Free Reference Dosimetry: Do We Really Need It?
D Campos1*, (1) Allegheny Health Network, Pittsburgh, PA