DISCLAIMER:
Entry of taxonomy/keywords during proffered abstract submission was optional.
Not all abstracts will appear in search results.
BReP-SNAP-T-34 | Commissioning and Validation of RayStation Treatment Planning for TomoTherapy Delivery Systems P Hill*, RA Bayliss, J Huang, M Lawless, Z Labby, J Smilowitz, University of Wisconsin, Madison, WI |
BReP-SNAP-T-89 | Initial Evaluation of the Radixact Synchrony System L Goddard*, K Jeong, W Tome, Montefiore Medical Center, Bronx, NY |
BReP-SNAP-T-114 | Predicting Optimal Plan Dose Distributions of Total Marrow Irradiation Using Deep Learning Model D Du*, J Neylon, J Wong, A Liu, City of Hope Medical Center, Duarte, CA |
PO-GeP-M-211 | Evaluation of the Accuracy of Deformable Image Registration On the TomoTherapy Treatment Planning System Y Nakajima1,2*, R Suganami1, S Hashimoto1, H Ogawa1, N Kadoya2, K Karasawa1, (1) Tokyo Metropolitan Cancer and Infectious Diseases Center Komagome Hospital, Tokyo, JP (2) Tohoku University Graduate School of Medicine, Sendai, JP |
PO-GeP-M-324 | Patient Dose From Kilovoltage Radiographic Images During Synchrony Treatments On the Radixact System W Ferris*, W Culberson, Univ of Wisc Madison, Madison, WI |
PO-GeP-T-56 | A Patient Plan Verification Confidence Limits Been Founded for TOMOTHERAPY HDA Type Machine T Pang*, L Yu, B Yang, J Qiu, Peking Union Medical College Hospital, Beijing, 11CN, |
PO-GeP-T-82 | Acquisition of 3D Dose Distribution for Helical Tomotherapy S Lim1*, (1) Kosin University Gospel Hospital, Kosin University College of Medicine, Seo-gu, BUSAN, KR |
PO-GeP-T-259 | Delivery Quality Assurance System Based On Simultaneous Verification of Three-Dimensional Dose Distribution and Mechanical Motion Y Tanaka1*, M Ishigami2, H Miyauchi1,3, K Takahashi1, M Nakano3, T Hasegawa4, M Hashimoto4,(1) Kitasato University Graduate School of Medical Sciences, Sagamihara, Kanagawa, JP, (2) Department of Radiology, Kitasato University Hospital, Sagamihara, Kanagawa, JP, (3) Cancer Institute Hospital of JFCR, Koto-ku, Tokyo, JP, (4) Faculty of Allied Health Sciences, Kitasato University, Sagamihara, Kanagawa, JP |
PO-GeP-T-366 | Effect of Pitch and Modulation Factor in Plan Quality for Helical Tomotherapy by Using AAPM TG119 Test Suites Venkatesan Kaliyaperumal*, T Kataria, Maragatha Veni, TamilSelvan, D Manigandan, Thushant Nair, Asif Ahmed, Rajesh S, Medanta The Medicity, Gurgaon, Haryana, India, |
PO-GeP-T-599 | Multi-Leaf Collimator Leaf Open Time Sinogram (LOTS) Based Patient Specific Quality Assurance: A Novel Approach for Total Marrow Irradiation Rajesh T1*, Dayananda S1, G Krishnan1, A Manikandan1, M Noufal1, K Patro1, A Nambiraj N2, S Kaushik1, R Jalali1, (1) Apollo Proton Cancer Centre, Chennai, Tamil Nadu, India, (2) Vit University, Vellore India |
PO-GeP-T-608 | On the Systematic Difference Between IROC TLD Measurements and Tomotherapy TPS Dose Calculation for Small Body Phantoms A Kapulsky*, A Ndlovu, Cancer Center & Hackensak Medical Center, Hackensack, NJ, Hackensack University Medical Center, Hackensack, NJ |
PO-GeP-T-756 | Testing Code of Practice (IAEA-AAPM) of Small Field Dosimetry for Tomotherapy R KINHIKAR, S Kaushik, C Tambe, S Kadam, S Kale, R Upreti, Tata Memorial Hospital, Mumbai, IN, |
PO-GeP-T-774 | The Impact of Jaw Positioning Errors for Dynamic Jaw Delivery in Tomotherapy Z Hu*, K Zhang, K Men, J Dai, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital,Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, BeijingCN, |