Keywords: Magnetic Fields
BReP-SNAP-M-42Comparison of Accuracy and Performance of Monte Carlo Dose Calculations Involving Magnetic Fields: ARCHER VS. TOPAS
L Mao1*, K Sheng2, Q Cheng3, H Yang3, J Wang4, X Pei1, X Xu1,3, (1) University Of Science And Technology Of China, Hefei, CN, (2) University Of Carlifornia, Los Angeles, CA, (3) Rensselaer Polytechnic Institute,Troy,NY,(4) MD Anderson Cancer Center, Houston, TX,
BReP-SNAP-T-25An Optimized Detector for Daily Quality Assurance Measurements of Magnetic Resonance Image Guided Radiation Therapy (MRgRT) Treatment Units
B Muir*, M McEwen, J Renaud, National Research Council, Ottawa, ON
BReP-SNAP-T-53Efficient Hybrid Scatter Solution for Deterministic MRIgRT Dose Calculations
R Yang1*, D Santos1, B Fallone1, J St-Aubin2, (1) Cross Cancer Institute, Edmonton, AB, Canada, (2) University of Iowa, Iowa City, IA
BReP-SNAP-T-87Influence of the Magnetic Field On the Cherenkov Light Collected by Optical Fiber Dosimeters
B Maraghechi1*, Y Hao1, R Zhang2, H Li1, S Mutic1, A Darafsheh1, (1) Washington University School of Medicine, St. Louis, MO, (2) Dartmouth College, Lebanon, NH
BReP-SNAP-T-149The Design of a Permanent Magnet Quadrupole Lens Focusing System for An Alpha-Irradiator
H Arya*, Y Lai, A Chalise, Y Cao, M Jin, Y Chi, University of Texas at Arlington, Arlington, Texas
MO-EF-TRACK 3-11Enabling Fast and Accurate Dose Calculation in Magnetic Fields Using Macro Monte Carlo
R Kueng*1, G Guyer1, W Volken1, D Frei1, F Stabel1, M F M Stampanoni2, P Manser1, M K Fix1, (1) Inselspital, Bern University Hospital, and University of Bern, Bern, CH, (2) ETH Zurich and PSI, Villigen, CH
PO-GeP-M-65ArcCHECK for Machine Commissioning and Patient Specific QA: Which Phantom Should Be Used?
Y Tian*, K Zhang, K Men, J Dai, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital,Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, Beijing,CN,
PO-GeP-T-6A Clinical Validation of the MR-Compatible Delta4 QA System in a 0.35 Tesla MR-Linac
V Desai*, J Bayouth, J Smilowitz, P Yadav, University of Wisconsin, Madison, WI
PO-GeP-T-109Angular Dependency of the Measurements of the Novel SRS MapCheck Device in the Magnetic Field
O Pen*, A Price, Washington University in St. Louis, St. Louis, MO
PO-GeP-T-204Commissioning Report of a High Field MR-Linac System
N Tyagi1*, E Subashi2, P Godoy Scripes3, J Mechalakos4, X Gonzalez Souto5, S Lim6, (1) Memorial Sloan-Kettering Cancer Center, New York, NY, (2) Memorial Sloan Kettering Cancer Center, New York, NY, (3) Memorial Sloan-Kettering Cancer Center, New York, NY, (4) Memorial Sloan-Kettering Cancer Center, New York, NY, (5) Elekta, Atlanta, GA, AF, (6) Memorial Sloan-Kettering Cancer Center, New York, NY
PO-GeP-T-365Effect of Magnetic Field On the Response of EBT-XD and EBT3 Radiochromic Films in MRIgRT
A Darafsheh*, Y Hao, B Maraghechi, R Khan, Washington University School of Medicine, St. Louis, MO
PO-GeP-T-421Evaluation of the Response of TLD Capsules and OSLD Nanodot Dosimeters in the Presence of a Magnetic Field
P Alvarez, R Howell, D Followill, S Smith*, UT MD Anderson Cancer Center - IROC, Houston, TX
PO-GeP-T-582Modeling and Testing of a Virtual Source Model for An Independent Monte Carlo Radiation Dose QA Software with the Magnetic Field Option
Q Cheng1*, H Yang1, Y Xu2, X Pei2,3, L Mao2, Q Ren3, A Wu5, D Adam4, B Bednarz4, P Caracappa6, X Xu1,2, (1) Rensselaer Polytechnic Institute, Troy, NY, (2) University of Science and Technology of China, Hefei, ,CN, (3) Anhui Wisdom Technology Company Limited, Hefei, ,CN, (4) University of Wisconsin- Madison, Madison, WI, (5) The First Affiliated Hospital of University of Science and Technology of China, Hefei, ,CN, (6) Virtual Phantoms, Inc., Albany, NY
PO-GeP-T-615Optimization and Construction of a Glass Vessel and MR-Compatible Water Calorimeter for Use in Clinical Photon and Electron Beams
M D'souza1*, H Nusrat2,3, V Iakovenko2,3, J Renaud3, A Sarfehnia1,2,3, (1) Department of Physics, Ryerson Univeristy, Toronto, ON, CA, (2) Department of Medical Physics, Odette Cancer Centre, Sunnybrook Health Sciences Centre, Toronto, ON, CA, (3) Department of Radiation Oncology, University of Toronto, Toronto, ON, CA, (4) National Research Council Canada, Ottawa, ON, CA
PO-GeP-T-673Quality Correction Factors of Small-Cavity Ionization Chambers in Small MR-Guided Radiotherapy Beams
Y Cervantes1,2*, I Billas3, S Duane3, H Bouchard1,2,4, (1) Universite de Montreal, Departement de physique, Montreal, QC, CA (2) Centre de recherche du Centre hospitalier de l'Universite de Montreal, QC, CA, (3) National Physical Laboratory, Teddington, UK,(4)Centre hospitalier de l'Universite de Montreal, Departement de radio-oncologie, Montreal, QC
PO-GeP-T-705Response of Parallel-Plate Ionization Chambers On the Buildup Dose Measurement in Inline Magnetic Fields
N Anami1*, F Araki2, T Ohno3, (1) ,Kumamoto University, Kumamoto,JP, (2) Kumamoto University, Kumamoto, JP, (3) Kumamoto University, Kumamoto, JP
SU-F-TRACK 3-7Verification of the Output Calibration of MR-Linac Beams Using Reference Alanine Dosimeters
M McEwen1*, V Malkov2, B Muir3, A Sarfehnia4, (1) National Research Council, Ottawa, ON, CA, (2) University Health Network, Toronto, ON, CA, (3) National Research Council, Ottawa, ON, (4) Sunnybrook Health Sciences Centre, Odette Cancer Centre, Department of Medical Physics, Toronto, ON, CA
TH-A-TRACK 5-5Magnetic-Modulated Radiation Therapy with High Energy Electron Beams
M Chen*, L Ma, X Gu, W Lu, UT Southwestern Medical Center, Dallas, TX
TU-EF-TRACK 2-15Investigation of Monaco Surface Dose Calculations Using Film Dosimetry
V Malkov*, K McPhee, T Craig, The Princess Margaret Cancer Centre, Toronto, ON, Canada