PO-GeP-M-44 | Accuracy of the 3D Reference Coordinate Definition with G-Frame for Gamma Knife ICON L Claps*, D Mathew, Y Watanabe, University of Minnesota, Minneapolis, MN |
PO-GeP-M-318 | Optimal Planning Target Volume Margin for Lung SBRT with Minimal Immobilization C Wilcken1, T Chow2, M Wierzbicki2*, (1) McMaster University, Hamilton, ON, CA (2) Juravinski Cancer Center, Hamilton, ON, CA |
PO-GeP-M-326 | Performance Evaluation of the Twist-Correction System for Head and Neck Radiotherapy Driven by Remote Control H Shimizu1,2*, K Sasaki2, T Aoyama1, T Kitagawa1, T Iwata1, H Fukuma3, H Tachibana1, T Kodaira1, (1) Aichi Cancer Center, Nagoya, Aichi, JP, (2) Gunma Prefectural College of Health Sciences, Maebashi, Gunma, JP, (3) Nagoya City University Hospital, Nagoya, Aichi, JP |
PO-GeP-M-421 | Validation of a Near-Infrared Pupil-Tracking Tool for Robotic Radiosurgery of Ocular Tumors J Megroureche1*, K Zerouali1,2, F Deblois1,2, D Roberge1, S Bedwani1,2, (1) Departement de radio-oncologie, Centre Hospitalier de l'Universite de Montreal, Montreal, QC, CA (2) Departement de physique, Universite de Montreal, Montreal, QC, CA |
PO-GeP-T-3 | 3D-Printed Headrest for Frameless Gamma Knife Radiosurgery: Design and Validation G Baltz*, T Briere, D Luo, R Howell, S Krafft, E Han, MD Anderson Cancer Ctr., Houston, TX |
PO-GeP-T-11 | A Comparison of Two Immobilization Systems for Prostate Radiotherapy F Mostafaei*, S Dougherty, R Hamilton, University of Arizona, Department of Radiation Oncology, Tucson, AZ |
PO-GeP-T-119 | Assessing Improvement in Setup Reproducibility for Head and Neck Patients Following 2 Cycles of Process Improvement A Heikal*, B Aboughoche, M Brennan, H Warkentin, Cross Cancer Institute, Edmonton, AB, Canada |
PO-GeP-T-244 | Continuous Positive Airway Pressure (CPAP) for Centrally Located Lung Tumours S Lydiard*, U Machold, G Le Grice, C King, S Hussain, L Lao |
PO-GeP-T-260 | Design and Evaluation of Catheter Immobilizer for Free-Hand High-Dose Rate Brachytherapy T Nano1, W Chen1*, D Capaldi2, I Hsu1, A Wong1, J Cunha1, (1) University of California, San Francisco, San Francisco, CA, (2) Stanford University, Stanford, CA |
PO-GeP-T-301 | Development of Real Time Thermoplastic Mask Compression Force Monitoring System Using Force Sensing Register (FSR) Sensor T Kim1*, T Suh2, S Kim3, D Shin2, D Shin1, (1) Proton Therapy Center, National Cancer Center, Goyang-si, Gyeonggi-do, KR, (2) Catholic Univ Medical College, Seoul, ,KR, (3) Virginia Commonwealth University, Richmond, VA, |
PO-GeP-T-307 | Does Custom Made Immobilization Improve Patient Setup? Analysis of Vacuum Bag Vs Off the Shelf Immobilization for Pelvis and Thorax Treatments S Hadley*, Y Sun, The University of Michigan, Ann Arbor, MI |
PO-GeP-T-424 | Evaluation of Treatment Planning System Accuracy in Estimating the Stopping Power Ratio of Immobilization Devices for Proton Therapy K Jiang*, M MacFarlane, S Mossahebi, M Zakhary, University of Maryland School of Medicine, Baltimore, MD |
PO-GeP-T-715 | Scripting API-Based Frame Coordinate Calculator for Stereotactic Body Radiotherapy Y Park1*, Z Iqbal1, A Pompos1 (1) UT Southwestern Medical Center, Dallas, TX |
PO-GeP-T-718 | Setting Table Coordinates Prior to Treatment Start Reduces Overrides and Increases Quality J Donaghue1*, S Gajdos2, (1) Cleveland Clinc Fairview, Rocky River, OH, (2) Cleveland Clinic Akron General, Strongsville, OH |