Keywords: Fluoroscopy
BReP-SNAP-M-13A Novel Real-Time Markerless Target Tracking Pipeline Based On Faster R-CNN for Lung Cancer Radiotherapy
L Deng1,4*, Z Dai2, X Liang3,4, H Zhao4, H Quan1, Y Xie4, (1) Wuhan University, Wuhan, Hubei, CN, (2) The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, CN, (3) Stanford Univ School of Medicine, Stanford, CA, (4) Shenzhen Institute Of Advanced Technology,Shenzhen, Guangdong, CN
BReP-SNAP-M-53Deep Neural Network-Based Prediction of Dual-Energy Subtraction Images From Single-Energy X-Ray Fluoroscopy: A Feasibility Study
J Wang1*, K Ichiji1, N Homma1, X Zhang2, Y Takai3, (1) Tohoku University, Sendai, JP, (2) National Institute of Technology, Sendai College, Sendai, JP, (3) Southern Tohoku BNCT Research Center, Koriyama, JP
PO-GeP-I-88Directly Measuring Peak Skin Dose During Fluoroscopically-Guided Neuroradiology Interventional Surgeries
N Quails*, D Laurent, B Corliss, B Hoh, A Polifka, W Fox, L Rill, M Arreola, University of Florida, Gainesville, FL
PO-GeP-I-91Does the Radiation Output From Mobile C-Arms of the Same Vendor Utilizing Different Image-Receptor Technology Differ?
J Dave1*, (1) Thomas Jefferson University, Philadelphia, PA
PO-GeP-I-146Linear Regression for Modeling Common Fluoroscopy Dose Metrics in Cardiac Catheterization Procedures
S Mann*, Z Wegermann, M Russ, T Wei, WS Jones, Duke University Medical Center, Durham, NC,
PO-GeP-M-127CT Vs. Fluoroscopy Guidance for Nusinersen Intrathecal Injection: Quantitative Evaluation of the Learning Process Effect On Patients Radiation Exposure
R Al Helo*, L Zimmermann, A Azar, N Bass, D Jordan, N Azar, University Hospitals Cleveland Medical Center, Cleveland, OH
PO-GeP-P-26A Simple Test Tool to Optimize Protocol in Real Time Fluoroscopic Imaging
R Livingstone*, B Pearline, A Singh, N Ahirwar, S Devasahayam, Christian Medical College, Vellore, TN IN,
PO-GeP-T-200Commissioning of a Free Breathing Amplitude Gated Treatment Program Using Varian TrueBeam 2.7 Imaging Capabilities
S Hickling*, A Veres, M Grams, Mayo Clinic, Rochester, MN
SU-B-TRACK 1-1BEST IN PHYSICS (IMAGING): Skin Dose Mapping by Convolution of the Dose Point Spread Function Over a Curved Surface
S-H Sun*, C Guo, S Rudin, D Bednarek, Univ. at Buffalo (SUNY) School of Med., Buffalo, NY
SU-B-TRACK 1-2The Application of a Correction for Angle of X-Ray Incidence in the Skin Dose Tracking System During Fluoroscopically-Guided Procedures
S-H Sun*, C Guo, S Rudin, D Bednarek, Univ. at Buffalo (SUNY) School of Med., Buffalo, NY
SU-B-TRACK 1-3Quantifying the Effectiveness of Non-Leaded Protective Drapes in Interventional Radiology and Cardiology
M Robins*, K Little, X Jiang, X Yang, J Zhang, D Hintenlang, Ohio State Univ, Columbus, OH
SU-B-TRACK 1-5(Un)Likelihood of Skin Injury When Substantial Radiation Doses Are Exceeded
M Vanderhoek*, C Morrison, Henry Ford Health System, Detroit, MI
TU-D-TRACK 1-5New Development of Blocking Layer and Doping of Amorphous Selenium to Improve the Imaging Performance of Flat-Panel Imager with Avalanche Gain
C Orlik1*, A Howansky1, S Leveille2, A Mishchenko2, J Stavro1, A Goldan1, J Scheuermann1, W Zhao1, (1) Stony Brook University, Stony Brook, NY, (2) Analogic Canada, Montreal, Canada
WE-CD-TRACK 4-0Fluoroscopic Dose Tracking: Trials, Tribulations, and Successes
R Fisher1*, O Christianson2*, B Schwarz3*, (1) MetroHealth, Cleveland, OH, (2) Landauer Medical Physics, Franklin Park, PA, (3) University of Florida, Gainesville, FL
WE-CD-TRACK 4-1Fluoroscopy Dose Tracking: Experiences with homegrown, non-commercial solutions
R Fisher1*, O Christianson2*, B Schwarz3*, (1) MetroHealth, Cleveland, OH, (2) Landauer Medical Physics, Franklin Park, PA, (3) University of Florida, Gainesville, FL
WE-CD-TRACK 4-2Fluoroscopy Dose Tracking: A Guide from Acquiring Data to Creating National Benchmarks
R Fisher1*, O Christianson2*, B Schwarz3*, (1) MetroHealth, Cleveland, OH, (2) Landauer Medical Physics, Franklin Park, PA, (3) University of Florida, Gainesville, FL
WE-CD-TRACK 4-3An Example Pre-, Intra- and Post-Procedure Clinical Workflow for General Fluoroscopy and FGI Procedures
R Fisher1*, O Christianson2*, B Schwarz3*, (1) MetroHealth, Cleveland, OH, (2) Landauer Medical Physics, Franklin Park, PA, (3) University of Florida, Gainesville, FL