MENU

Click here to

×

Are you sure ?

Yes, do it No, cancel

DISCLAIMER:
Entry of taxonomy/keywords during proffered abstract submission was optional.
Not all abstracts will appear in search results.

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # | show all

Keywords: Eye Plaques
BReP-SNAP-T-33Characterization of Novel Ferrofluid for Intraocular Photon Shielding by Monte Carlo and Film Dosimetry Methods
C Oare*, C Ferreira, Y Watanabe, B Gerbi, University of Minnesota, Minneapolis, MN
BReP-SNAP-T-134Update of the Carleton Laboratory for Radiotherapy Physics (CLRP) Dosimetric Database for Eye Plaque Brachytherapy with Photon-Emitting Sources
H Safigholi1*, Z Parsons1, S Deering1, R Thomson1, (1) Carleton Laboratory for Radiotherapy Physics, Department of Physics, Carleton University, Ottawa, ON, CA
PO-GeP-T-49A Novel Method for Determining Optic Nerve and Disc Location for Eye Plaque Treatment Planning
S Scarboro1*, M Astrahan2, (1) University of Virginia, Charlottesville, VA, (2) University of Southern California, Los Angeles, CA
PO-GeP-T-144Automation of Eyeplaque Procedures for Greater Integration and Safety
Q Diot*, D Westerly, M Miften, University of Colorado School of Medicine, Aurora, CO
PO-GeP-T-213Comparison Between COMS Plaques and Personalized 3D Printed 103Pd-Loaded Plaques with Dose Modulations for Ocular Melanomas
Y Ma1*, T Lescot2, M Fortin3, L Beaulieu4, (1) CHU de Quebec, Quebec, QC, CA, (2) CHUQ-Hospital St Francis d'Assise, Quebec, QC, CA, (3) CHUQ-Hospital St Francis d'Assise, Quebec, QC, CA, (4) Centre Hospitalier Univ de Quebec, Quebec, QC, CA
PO-GeP-T-441Eye Plaque Brachytherapy Treatment Planning with Fundus Image-Based Tumor Modeling: Retrospective Institutional Experience
I Chibirev1*, S Meltsner2, Z Chang3, M Materin4, D Kirsch5, O Craciunescu6, (1) Duke University, Durham, NC, (2) Duke University Medical Center, Durham, NC, (3) Duke University Medical Center, Durham, NC, (4) Duke University Medical Center, ,,(5) Duke University Medical Center, Durham, NC, (6) Duke University Medical Center, Durham, NC
PO-GeP-T-575Measured, Calculated and Monte Carlo Simulated Dose Distributions in a Unique Gold Applicator Loaded with I-125 Seeds
C Trauernicht1*, E Hering2, F Du Plessis3, G Maree4, D Van Eeden3, (1) Tygerberg Hospital and Stellenbosch University, Cape Town, ZA, (2) University Of Cape Town, Cape Town, ZA, (3) University Of The Free State, Bloemfontein, ZA, (4) Groote Schuur Hospital, Cape Town, ZA,
PO-GeP-T-657Preliminary Studies of a New Method for Confirming the Activity of Ru106 Plaques for Uveal Melanoma
M Hauze1*, A Portocarrero Bonifaz2, T Ma3, D Wilkinson4, (1) Cleveland State University, Cleveland, OH, (2) Cleveland State University, Cleveland, OH, (3) The Cleveland Clinic Foundation, Cleveland, OH, (4) Cleveland Clinic Foundation, Cleveland, OH